What are the limits for H7/g6, H7/k6, H7/p6 or any other fit? Enter the nominal size and pick a preferred fit, or build your own from a hole class and a shaft class. You get both parts' deviations and limits, the clearance or interference range, the fit type, a to-scale zone diagram, gauge sizes, and for transition fits how often a random pair would end up tight.
Engineering estimate, not a quote. Limits apply at the ISO reference temperature of 20 Β°C; check them against the edition of ISO 286 named on your drawing.
A fit is the relationship between a hole and the shaft that goes into it. ISO 286 describes each of them with a tolerance class made of a letter and a number, such as H7 for the hole and g6 for the shaft. The number is the international tolerance grade (IT grade). It sets how wide the zone is, and the width grows with size. The letter is the fundamental deviation. It sets where the zone sits relative to the nominal size (the zero line). Capital letters are holes and small letters are shafts. Put the two classes together and the clearance or interference follows.
Step 1: find the size range. ISO 286 groups nominal sizes into ranges written "over A up to and including B", so 30 mm belongs to the 18β30 range, not 30β50. The main ranges (up to 3, 3β6, 6β10, 10β18, 18β30, 30β50, 50β80, 80β120, 120β180, 180β250, 250β315, 315β400, 400β500) set the IT values and most deviations. Some letters (c, r, s, u here) split the main ranges into intermediate ranges such as 18β24 and 24β30.
Step 2: read the IT value. For sizes up to 500 mm the standard tolerances come from the tolerance unit i = 0.45Β·βD + 0.001Β·D (micrometres, D = geometric mean of the range in mm). Then IT5 = 7i, IT6 = 10i, IT7 = 16i, IT8 = 25i, IT9 = 40i, IT10 = 64i and IT11 = 100i, rounded by the standard's rules. The tables below hold the rounded values, which are what you must use.
Step 3: place the zone. Shafts a to h have their upper deviation es fixed by the letter, so the lower deviation is ei = es β IT. Shafts k to zc have their lower deviation ei fixed, so es = ei + IT. h has es = 0 and js is symmetric, Β±IT/2. Holes mirror shafts: for A to H the lower deviation is EI = βes of the same letter, and for K to ZC the upper deviation is ES = βei. H has EI = 0.
Step 4: the Ξ rule. For holes K, M and N up to grade 8 and P to ZC up to grade 7, ISO 286-1 adds a correction: ES = βei + Ξ, where Ξ = ITn β ITnβ1 for the hole's grade n. This makes a shaft-basis fit identical to its hole-basis twin when the hole is one grade coarser than the shaft, so K7/h6 behaves exactly like H7/k6. Above those grades the plain rule applies, except that K and N above grade 8 have ES = 0 (for sizes over 3 mm). Up to 3 mm, Ξ is zero. The standard also lists one special value: M6 in the 250β315 range has ES = β9 Β΅m, not the β11 the rule gives. The calculator applies all of these.
Step 5: the fit. The loosest pair is the largest hole with the smallest shaft, and the tightest pair is the smallest hole with the largest shaft. A fit where even the tightest pair has clearance is a clearance fit; one where even the loosest pair is tight is an interference fit; anything in between is a transition fit.
| Range (mm) | IT5 | IT6 | IT7 | IT8 | IT9 | IT10 | IT11 |
|---|---|---|---|---|---|---|---|
| up to 3 | 4 | 6 | 10 | 14 | 25 | 40 | 60 |
| >3β6 | 5 | 8 | 12 | 18 | 30 | 48 | 75 |
| >6β10 | 6 | 9 | 15 | 22 | 36 | 58 | 90 |
| >10β18 | 8 | 11 | 18 | 27 | 43 | 70 | 110 |
| >18β30 | 9 | 13 | 21 | 33 | 52 | 84 | 130 |
| >30β50 | 11 | 16 | 25 | 39 | 62 | 100 | 160 |
| >50β80 | 13 | 19 | 30 | 46 | 74 | 120 | 190 |
| >80β120 | 15 | 22 | 35 | 54 | 87 | 140 | 220 |
| >120β180 | 18 | 25 | 40 | 63 | 100 | 160 | 250 |
| >180β250 | 20 | 29 | 46 | 72 | 115 | 185 | 290 |
| >250β315 | 23 | 32 | 52 | 81 | 130 | 210 | 320 |
| >315β400 | 25 | 36 | 57 | 89 | 140 | 230 | 360 |
| >400β500 | 27 | 40 | 63 | 97 | 155 | 250 | 400 |
| Range (mm) | d (es) | e (es) | f (es) | g (es) | h (es) | k (ei, IT4β7) | m (ei) | n (ei) | p (ei) |
|---|---|---|---|---|---|---|---|---|---|
| up to 3 | β20 | β14 | β6 | β2 | 0 | 0 | +2 | +4 | +6 |
| >3β6 | β30 | β20 | β10 | β4 | 0 | +1 | +4 | +8 | +12 |
| >6β10 | β40 | β25 | β13 | β5 | 0 | +1 | +6 | +10 | +15 |
| >10β18 | β50 | β32 | β16 | β6 | 0 | +1 | +7 | +12 | +18 |
| >18β30 | β65 | β40 | β20 | β7 | 0 | +2 | +8 | +15 | +22 |
| >30β50 | β80 | β50 | β25 | β9 | 0 | +2 | +9 | +17 | +26 |
| >50β80 | β100 | β60 | β30 | β10 | 0 | +2 | +11 | +20 | +32 |
| >80β120 | β120 | β72 | β36 | β12 | 0 | +3 | +13 | +23 | +37 |
| >120β180 | β145 | β85 | β43 | β14 | 0 | +3 | +15 | +27 | +43 |
| >180β250 | β170 | β100 | β50 | β15 | 0 | +4 | +17 | +31 | +50 |
| >250β315 | β190 | β110 | β56 | β17 | 0 | +4 | +20 | +34 | +56 |
| >315β400 | β210 | β125 | β62 | β18 | 0 | +4 | +21 | +37 | +62 |
| >400β500 | β230 | β135 | β68 | β20 | 0 | +5 | +23 | +40 | +68 |
k has ei = 0 for grades up to IT3 and from IT8 up. The letters c, r, s and u use intermediate ranges and are tabulated in the calculator's source; at 25 mm they are c β110 (es), r +28, s +35 and u +48 (ei, range 24β30). The holes use the same numbers through the mirror and Ξ rules above.
A 25 mm steel pin has to locate a lever. Three options are on the table: a sliding fit (H7/g6) so the lever can be taken off by hand, a transition fit (H7/k6) for tighter location, and a locational interference fit (H7/p6) so the lever never rattles. 25 mm is in the 18β30 range (and the 24β30 intermediate range), where IT7 = 21 Β΅m and IT6 = 13 Β΅m.
Three things stand out. First, the whole difference between "slides by hand" and "needs a press" is a 42 Β΅m shift of the shaft zone (from g6 at β7/β20 to p6 at +35/+22), less than half the thickness of a sheet of paper, which is why fits are specified by class and not by eye. Second, the transition fit is not "slightly loose": about a third of random H7/k6 pairs would be tight if both parts' sizes were centred and normally spread, and the worst pair has 15 Β΅m of interference. If the lever has to come off in the field, H7/k6 is the wrong choice. Third, H7/p6 has only 1 Β΅m of guaranteed interference. It locates rigidly but cannot be counted on to carry torque. For a torque-carrying joint, size the interference with the press-fit calculator (H7/s6 or H7/u6 territory) and check the hub stress. Press Load the worked example to reproduce the H7/g6 lines, then switch the preset to H7/k6, H7/p6 and K7/h6.
The preferred fits are a short list that covers almost every need, chosen so that a shop needs few reamers and gauges. Values below are at 25 mm. The list is the same in hole-basis and shaft-basis form.
| Fit (hole / shaft basis) | Type | Clearance (+) / interference (β) at 25 mm, Β΅m | Typical use |
|---|---|---|---|
| H11/c11 Β· C11/h11 | Clearance | +110 β¦ +370 | Loose running: wide tolerances, dirt, coatings, pivots on fabrications |
| H9/d9 Β· D9/h9 | Clearance | +65 β¦ +169 | Free running: large temperature swings, high speeds, heavy journal pressure |
| H8/f7 Β· F8/h7 | Clearance | +20 β¦ +74 | Close running: accurate location at moderate speed, machine spindles in plain bearings |
| H7/g6 Β· G7/h6 | Clearance | +7 β¦ +41 | Sliding: parts that move and turn freely and locate accurately, not for running |
| H7/h6 | Clearance | 0 β¦ +34 | Locational clearance: stationary parts that can be assembled and taken apart freely |
| H7/k6 Β· K7/h6 | Transition | +19 β¦ β15 | Locational transition: accurate location, light tapping, a compromise between clearance and interference |
| H7/n6 Β· N7/h6 | Transition | +6 β¦ β28 | Locational transition, tighter: more accurate location where more interference is acceptable |
| H7/p6 Β· P7/h6 | Interference | β1 β¦ β35 | Locational interference: rigid location and alignment without special bore pressure needs |
| H7/s6 Β· S7/h6 | Interference | β14 β¦ β48 | Medium drive: ordinary steel parts, shrink fits on light sections, the tightest usable on cast iron |
| H7/u6 Β· U7/h6 | Interference | β27 β¦ β61 | Force: parts that can take high stress, or shrink fits where heavy pressing force is impractical |
| Method | Use it when | Limit |
|---|---|---|
| ISO 286 fit (this page) | Cylindrical (or parallel-face) features that fit together: pins, shafts, bushings, bores, keys in slots | Gives limits only; does not check stress, torque or temperature |
| Press-fit interference calculation (LamΓ©) | Interference fits that must carry torque or axial load, or a plastic or thin hub | Needs material data and a chosen interference, which ISO 286 supplies |
| ANSI B4.1 inch fits (RC, LC, LT, LN, FN classes) | Inch-based drawings that call out fit classes such as RC4 or FN2 | Different class system; do not mix with ISO letters |
| ISO 2768 general tolerances | Non-critical dimensions with no individual tolerance | Far too loose for fits: Β±0.2 mm at 25 mm in class m |
| Tolerance stack-up | A gap or position that depends on several parts in a chain | Uses the limits a fit gives you as inputs |
| Bearing maker's fit tables | Rolling bearing seats on shafts and in housings | Depend on load direction and size, often k5, m6, J7 and similar |
IT values, fundamental deviations, the size ranges, the Ξ rule and the M6 (250β315 mm) special case are from ISO 286-1:2010, Geometrical product specifications (GPS): ISO code system for tolerances on linear sizes, Part 1: Basis of tolerances, deviations and fits, with the tolerance unit and grade multipliers from its annex. ISO 286-2:2010 tabulates the limit deviations for the commonly used classes and is the check used for the values on this page. The preferred fit list and descriptions follow ISO 286-1 and ANSI B4.2, Preferred Metric Limits and Fits. The envelope requirement is from ISO 14405-1 and ISO 8015. The statistical estimate for transition fits (zone width = 6Ο, centred normal distributions) and the gauge-size summary are this page's own calculations, not part of the standard. Where ISO 286-2 does not list a class you build here, the limits follow the ISO 286-1 rules; confirm against your copy of the standard before use.
For a 25 mm nominal size (ISO 286 range over 18 up to 30 mm), H7 is +0.000 / +0.021 mm, so the hole is 25.000 to 25.021 mm, and g6 is β0.007 / β0.020 mm, so the shaft is 24.980 to 24.993 mm. The minimum clearance is 0.000 β (β0.007) = 0.007 mm and the maximum clearance is 0.021 β (β0.020) = 0.041 mm. H7/g6 is a clearance fit, the usual sliding fit for parts that must move or be assembled by hand with accurate location.
Each tolerance class is a letter and a number. The number is the IT grade: look up the standard tolerance IT for the nominal size range (IT7 for 18 to 30 mm is 21 Β΅m). The letter is the fundamental deviation, the limit nearest the zero line: for shafts a to h it is the upper deviation es, for shafts k to zc the lower deviation ei; holes mirror the shafts. The other deviation is the fundamental deviation Β± IT. Limits are the nominal size plus the deviations. Maximum clearance = hole upper deviation ES β shaft lower deviation ei; minimum clearance = hole lower deviation EI β shaft upper deviation es. A negative clearance is an interference.
All three use the same H7 hole; only the shaft zone moves up. At 25 mm, H7/k6 runs from 0.019 mm clearance to 0.015 mm interference and H7/n6 from 0.006 mm clearance to 0.028 mm interference: both are transition fits, used for accurate location where parts may be assembled with light force and are not expected to transmit load by friction alone. H7/p6 runs from 0.001 to 0.035 mm interference, a locational interference fit that always has some interference and is pressed together. For a fit that must transmit torque by friction, H7/s6 or H7/u6 are used, sized with a press-fit stress calculation.
In a hole-basis system every hole is H (lower deviation zero) and the shaft letter sets the fit, for example H7/g6 or H7/p6. In a shaft-basis system every shaft is h (upper deviation zero) and the hole letter sets the fit, for example G7/h6 or P7/h6. Hole basis is the usual choice because holes are made with fixed-size reamers and checked with fixed plug gauges, so one hole size serves many fits. Shaft basis suits drawn bar stock used as-is, or one long shaft carrying several parts with different fits. ISO 286 sets the hole deviations so that equivalent pairs such as H7/k6 and K7/h6 give the same clearance and interference.
For holes K, M and N up to grade 8 and holes P to ZC up to grade 7, ISO 286-1 sets the upper deviation ES = βei + Ξ, where ei is the lower deviation of the shaft with the same letter and Ξ = IT(n) β IT(nβ1) for the hole grade n. The Ξ makes a hole-basis fit and its shaft-basis twin identical when the hole is one grade coarser than the shaft. Example at 25 mm: k has ei = +0.002 mm, IT7 = 21 and IT6 = 13 Β΅m, so Ξ = 8 and K7 has ES = β2 + 8 = +6 and EI = 6 β 21 = β15 Β΅m. K7/h6 then matches H7/k6 exactly. Ξ is zero up to 3 mm.
Common starting points from the ISO and ANSI B4.2 preferred fits: H11/c11 loose running for wide commercial clearances; H9/d9 free running where temperature changes or large journals matter; H8/f7 close running for accurate running at moderate speed; H7/g6 sliding for parts that move and locate accurately; H7/h6 locational clearance for parts assembled freely but located; H7/k6 and H7/n6 locational transition; H7/p6 locational interference for rigid location without torque; H7/s6 medium drive and H7/u6 force fit for permanent joints transmitting load. Rolling bearings are an exception: use the shaft and housing fits in the bearing maker's catalogue, which depend on load direction and magnitude.
ISO 286 defines tolerance classes for any feature of size, but grades IT6 and IT7, the grades of H7/g6 and H7/p6, are machining and grinding grades. Molded plastic holes and pins vary with shrinkage, wall thickness, moisture and temperature, and usually need much coarser grades. For a metal pin pressed into a plastic boss, size the interference from strain and hoop stress with a press-fit calculation instead of copying a metal fit, and confirm the molded hole tolerance with the molder before the tool is cut.
By the Taylor principle the go gauge checks the maximum material limit and the no-go gauge checks the least material limit. For a hole the go plug is the minimum hole size and the no-go plug is the maximum: for 25 H7, go 25.000 mm and no-go 25.021 mm. For a shaft the go ring or snap gauge is the maximum shaft size and the no-go is the minimum: for 25 g6, go 24.993 mm and no-go 24.980 mm. Gauge makers' tolerances and wear allowances are applied inside these limits.
Not sure whether your pin should slide, locate or press, or whether a molded part can hold the fit you need? Ask our AI assistant. It answers from this website, and our engineering team follows up if you want.
AI assistant. Answers can be wrong; nothing it says is a quote or a promise.
This calculator gives an engineering estimate. Our engineering team reviews pins, bores, bushings and press fits for the right class, the material and temperature effects, and whether a molded or cast feature needs a machined insert or a different fit, while each change is still a drawing edit.
Book a 30-min call Send a drawing or sample