ISTA 1A is a basic integrity screen, 2A a partial simulation that adds conditioning and compression, and 3A a general simulation of parcel delivery. Specify 1A to screen a pack early, 2A to refine a design or for international distribution, and 3A when the product travels alone by parcel.
The International Safe Transit Association (ISTA) publishes numbered series of pre-shipment test procedures for packaged products. 1A, 2A and 3A are the first procedure in each of the first three series, and ISTA's test procedures page puts each in a different category. The 1-Series are non-simulation integrity tests, which ISTA says "challenge the integrity of the product and package combination." The 2-Series are partial simulation tests: a "more thorough screening test useful for refining preliminary designs," and "not intended to be predictive of shipping performance." The 3-Series are general simulation tests, and ISTA calls them "useful as a predictive tool to understand risk of damage."
ISTA's own guidance frames the choice as screening against prediction. A screening test tries to avoid serious damage in shipment by challenging how strong and robust the product and package are, without trying to copy the trip. Prediction is the harder goal: foreseeing subtler effects such as minor or occasional damage, so a pack can be trimmed without raising the damage rate. 1A is a screen and 3A is built for prediction. 2A sits between them; ISTA says a 2-Series test adds at least one element of a 3-Series test, such as atmospheric conditioning or mode-shaped random vibration, to the basic elements of a 1-Series test.
Some points hold for all three. The product and package are tested together, not separately. Each overview warns that some conditions of transit, "such as moisture, pressure or unusual handling," may not be covered. And each says ISTA tests "do not necessarily comply with carrier packaging regulations," so a pass is evidence about one pack design, not an approval from a carrier.
This page summarises the free overview documents ISTA posts for each procedure. It does not reproduce the procedures, which ISTA sells in its store and provides free to members. The test levels quoted below come from the overview versions on ista.org (1A 2014, 2A 2011, 3A 2018). ISTA's change log lists later editorial changes to all three, for example in July 2022, so check the current ISTA procedure before you put a version on a purchase order.
| ISTA 1A | ISTA 2A | ISTA 3A | |
|---|---|---|---|
| ISTA category | Non-simulation integrity | Partial simulation | General simulation |
| What ISTA positions it for | Screening a pack early in design; comparing package and product alternatives | Refining a design; ISTA says to consider it for international distribution | Individual packages shipped through a parcel delivery system, by air or ground |
| Weight scope | 150 lb (68 kg) or less | 150 lb (68 kg) or less | 70 kg (150 lb) or less, by parcel carrier |
| Temperature and humidity | Ambient preconditioning only | Ambient preconditioning, then controlled conditioning chosen from a chart (both required) | Ambient preconditioning required; controlled conditioning optional |
| Compression | None | Required, by one of three methods | No separate test; vibration runs with and without a top load |
| Vibration | Fixed displacement, 1 in (25 mm) peak to peak | Two vibration steps, each fixed displacement or random (1.15 Grms overall) | Random, with and without top load (0.53 and 0.46 Grms overall); optional run under low pressure |
| Shock | One test: drop, incline impact or horizontal impact | One test from the same three options | Two drop blocks; extra impacts for flat and elongated packages |
| Samples | 1 required; 5 or more recommended | 1 required; 5 or more recommended | 1 required; 2 or more recommended for fragile and liquid products; 5 or more encouraged |
| Overview version on ista.org | 1A 2014 | 2A 2011 | 3A 2018 |
The weight row is not a typo. ISTA's other procedures convert 150 lb as 68 kg, but the 3A overview uses 70 kg and 150 lb because that is "a common dividing point found in parcel delivery systems" in countries on either unit system. Above 150 lb, ISTA has separate procedures, such as 1B for integrity testing and 2B for partial simulation. The 1A and 2A overviews also note that an individual packaged product on a visible skid or pallet weighing more than 100 lb (45 kg) may be tested under 1B or 1E, or under 2B or 3E.
1A runs a single sample through three steps in a fixed order. The sample is preconditioned at ambient temperature and humidity, vibrated on a fixed-displacement table at 1 in (25 mm) peak to peak, and then given one shock test, chosen from a free-fall drop, an incline impact or a horizontal impact. Drop height or impact velocity is set by the weight of the packaged product. The overview calls 1A an integrity test that can evaluate a packaged product and can "compare relative performance of package and product design alternatives." ISTA requires the procedure to be run once and recommends five or more runs, each on a new sample.
The 1A overview is candid about its limits and points to other tests for specific needs. If you want random vibration instead of a fixed displacement, the overview says to use 1G, not 1A; if a minimum compression value should be tested, 1C. For international distribution, the overview says to consider 2A, and for packs that may travel through a small parcel delivery system, to consider 3A. ISTA's selection guidance groups 1A, 1C and 1G as preliminary design screening tests for packages of 150 lb or less.
That makes 1A the right call when a pack concept and a first sample exist and the question is simply whether the product and its insert hold together, or when two inserts need a quick comparison. ISTA also notes that 1-Series tests are useful as screens "particularly when used as a consistent benchmark over time," so a buyer can keep 1A as a repeat check, for example when a carton supplier changes, as long as everyone treats the result as a screen.

2A keeps vibration and shock from the 1-Series but runs a longer sequence of six steps: ambient preconditioning, controlled temperature and humidity conditioning chosen from a chart, compression, vibration, shock, and vibration again. Both atmospheric steps are listed as required for ISTA certification. Compression can be run three ways: a machine apply-and-release test at the calculated test force times 1.4, a machine apply-and-hold test at the calculated force, or a weight and load spreader. Each vibration step can be fixed displacement or random at an overall level of 1.15 Grms, and the report should state which method was used for each.
The compression rule is the detail buyers tend to miss. Under the 2A overview, a box failure that could result in a stacking failure counts as a failed test if the packaged product may be warehoused during distribution. If it will not be warehoused, a box failure is allowed, provided the product is undamaged against the damage tolerance set before the test and the package still meets its acceptable condition. Tell the lab whether your cartons will sit in a warehouse stack, because the answer changes what counts as a pass.
ISTA says 2A "should be considered for the evaluation of packaged-products intended for international distribution," while repeating that a partial simulation does not predict field performance. In practice that makes 2A a design-refinement test: checking two board grades against each other, or confirming that a pack still holds after humid conditioning, before a full 3A run.
3A is a general simulation test for individual packaged products shipped through a parcel delivery system, by air or ground. ISTA's selection guidance names it for parcel delivery in North America for packages of 150 lb (68 kg) or less, and for e-commerce shipments sent direct from manufacturer to consumer; ISTA lists a separate procedure, 3P, for the parcel network in India. Test levels, the overview says, are based on general data and may not represent any specific distribution system.
For standard, flat and elongated packages, the sequence is ambient preconditioning; optional controlled conditioning; a first block of nine drops; random vibration with and without a top load, at overall levels of 0.53 and 0.46 Grms; optional random vibration under low pressure; and a second block of eight drops that includes a drop onto a hazard. Drop heights vary with weight. The low-pressure step simulates high altitude and checks whether a primary or transport package holds its seal and keeps liquid, powder or gas from leaking. Flat and elongated packages add a rotational edge drop and a full rotational flat drop. Flat packages also take a concentrated impact from a 4.1 kg (9 lb) hazard box dropped 400 mm (16 in), and elongated packages take a bridge impact. Products containing liquids finish with an 8-hour leak test. Small packages follow their own path: nine drops, vibration, then seven drops inside a bag.
3A asks for records that matter later. When the outer package is a corrugated box, the overview strongly recommends recording the basis weights of the papers used to make it, and says a retest is appropriate if the nominal basis weights change, "even if the board is rated for the same performance." It also recommends photographs, because "significant variations in performance can sometimes be caused by seemingly insignificant differences." For hazardous materials, a 3A pass is not a substitute for UN or other required transport tests.
3A runs a different set of drops and impacts for each package type, so the type has to be settled before the lab quotes. The 3A overview defines them by size and weight:
Here are five made-up shipping boxes run through those rules. The sizes and weights are illustrative only, not products or quotes.
| Box (made-up) | Check | 3A type |
|---|---|---|
| A: 220 × 160 × 90 mm, 1.1 kg | 22 × 16 × 9 = 3,168 cm³, under 13,000; longest 220 mm, under 350; 1.1 kg, under 4.5 | Small |
| B: 380 × 250 × 120 mm, 2.0 kg | 38 × 25 × 12 = 11,400 cm³, under 13,000, but longest 380 mm is over 350, so not small; volume under 13,000, so not flat; longest under 900, so not elongated | Standard |
| C: 420 × 300 × 180 mm, 3.8 kg | 42 × 30 × 18 = 22,680 cm³; shortest 180 mm is under 200, but 300 is less than 4 × 180 = 720, so not flat | Standard |
| D: 640 × 480 × 70 mm, 5.2 kg | 64 × 48 × 7 = 21,504 cm³, over 13,000; shortest 70 mm, under 200; 480 is more than 4 × 70 = 280 | Flat |
| E: 1,000 × 150 × 120 mm, 4.0 kg | Longest 1,000 mm, over 900; 150 is 15% and 120 is 12% of 1,000, both 20% or less | Elongated |
Box B is the one to watch: it is light and under the small-package volume, yet one dimension 30 mm too long moves it to the standard sequence. Box D, a typical flat retail pack, picks up the concentrated hazard-box impact and the rotational drops that box C never sees. If your carton sits near a boundary, a small change to the insert or the carton can change the test, so check the dimensions against the current ISTA procedure before the dieline is frozen.
ISTA's tests run from screening tools used early in design (1-Series) to general simulations of one type of shipment (3-Series), and its guidance says that in some cases more than one test should be run and the results compared, with trial shipments used alongside lab work. For a new pack, a common path follows that order: screen with 1A, refine with 2A, and confirm a parcel pack with 3A or the retailer's test.
A transit test only protects a buyer if the order says exactly what was agreed. Put these in writing before samples go to the lab:
On a JCH program, the transit test, the lab and the sample plan are whatever the written program spec names; this page does not state that any pack has passed any test. For the rest of a packaging spec, see custom packaging: what to specify, the packaging step, protective cases and foam inserts and packaging and retail-ready questions. Inspection of packed goods before they leave is covered in the pre-shipment inspection checklist.
Usually not. 1A is a non-simulation integrity screen, and the 1A overview itself says to consider 3A for packaged products that may travel through a small parcel delivery system. Use 1A to screen a pack early, then confirm a parcel pack with 3A or with the test your customer names.
No. ISTA describes partial simulation tests as useful for refining preliminary designs and "not intended to be predictive of shipping performance." The 3-Series general simulation tests are the ones ISTA calls a predictive tool.
1A and 2A cover individual packaged products of 150 lb (68 kg) or less. 3A covers 70 kg (150 lb) or less shipped by a parcel carrier; ISTA uses 70 kg there because it is a common dividing point in parcel delivery systems. Heavier packs go to other ISTA procedures, such as 1B or 2B.
Each overview requires the procedure to be run once on one sample. ISTA recommends five or more runs with new samples for 1A and 2A, recommends two or more samples for fragile and liquid products under 3A, and encourages five or more for all 3A package types.
Only if you ask. Ambient preconditioning is required, but controlled temperature and humidity conditioning and random vibration under low pressure (simulated high altitude) are optional blocks in the 3A overview. If your product needs them, write them into the test request.
No. ISTA lists 6-Amazon.com and 6-Sams Club as Member Performance Tests, a separate series built around one company's supply chain. If a retailer names its own test, test to that one; a 3A report does not stand in for it unless the retailer says so.
They are different standards from different bodies. Life Science Outsourcing, a test lab, describes ISTA procedures as standardized protocols, while ASTM D4169 allows customization through assurance levels, distribution cycles and test schedules; the same lab calls ISTA standards voluntary. A test becomes a requirement when your customer, retailer or contract names it.
The current one at the time of testing. The overviews ISTA posts are labelled 1A 2014, 2A 2011 and 3A 2018, and ISTA accepts a test report based on a previous version for up to one year after a revision is published. Check the current ISTA procedure before you write a version on a purchase order.
Have a product whose pack has to survive parcel shipping or a retailer's test? Send the drawing and tell us how it will ship, and we'll go through the packaging spec with you. NDA first if you want one.
Send a part for reviewBook a 30-minute callHave a question about ISTA 1A, 2A and 3A? Ask our AI assistant. It answers from this website, and our tooling team follows up if you want.
AI assistant. Answers can be wrong; nothing it says is a quote or a promise.