Sheet Metal Bend Allowance, Bend Deduction & K-Factor Calculator
The flat blank for a bent sheet metal part is the sum of its outside flange dimensions minus one bend deduction per bend, where the bend deduction is BD = 2·(R + T)·tan(θ/2) − BA and the bend allowance is the neutral-axis arc BA = θ·(R + K·T), with θ in radians.
Enter thickness, inside radius, bend angle and K-factor to get the bend allowance, outside setback, bend deduction and the developed length for a bracket, channel or box side with any number of identical bends. Switch to the test-bend tab to back-calculate the K-factor your press brake actually produces.

Engineering estimate, not a quote. The bend that comes off a real press brake depends on the sheet lot, grain direction, tooling and bending method; confirm the K-factor with a test bend before cutting production blanks.
How this works
When a press brake folds a strip of sheet, the metal on the inside of the bend is squeezed and the metal on the outside is stretched. Somewhere between the two faces is a layer that neither shortens nor lengthens: the neutral axis. Because that layer keeps its length, it is the one you can unfold on paper to get the flat blank. Its position is described by the K-factor, the distance from the inside face to the neutral axis divided by the thickness. A K of 0.5 puts it exactly at mid-thickness; real bends push it toward the inside face, so practical values sit roughly between 0.3 and 0.5.
Bend allowance. Through the bend itself the neutral axis is an arc of radius R + K·T swept through the bend angle θ. Its length is the bend allowance. With θ in degrees the π/180 converts to radians:
Bend deduction. Drawings rarely dimension the flat part of a flange. They dimension to the outside faces, and those faces meet at an imaginary corner called the outside virtual sharp (or mold line). Each flange measured to that corner is longer than its flat portion by one outside setback, so a bend that joins two flanges has added two setbacks to the drawing numbers while the metal only needs one bend allowance. The difference, 2·OSSB − BA, is the bend deduction: take it off the sum of the outside dimensions once for every bend and you have the blank. If the flanges are given to the inside faces, the setback is the shorter R·tan(θ/2); if they are already flat lengths measured to the bend tangent lines, there is nothing to deduct and you add the allowance instead. The calculator handles all three, and the worked example shows that they converge on the same blank when the drawing is consistent.
Worked example 1: a U channel from outside dimensions
A channel in 1.5 mm cold-rolled steel is drawn 20 × 40 × 20 mm to the outside faces, with two 90° bends at a 1.5 mm inside radius. The Machinery's Handbook group for cold-rolled steel uses Y = 0.71, so K = 0.71 ÷ 1.5708 = 0.452. Press Load the worked example to reproduce it.
All three dimensioning conventions land on 74.8424 mm, which is the check worth doing whenever a drawing mixes inside and outside dimensions. Note that the inside-dimension case adds length at a 90° bend: the inside setbacks (3.0 mm per bend) are smaller than the allowance (3.42 mm), so the inside numbers alone come up short.
Worked example 2: the angle convention trap
A 2 mm aluminum bracket opens to a 135° included angle with a 2 mm inside radius, K = 0.4074 (Handbook Y 0.64). The flange turns through 180 − 135 = 45°:
The wrong entry over-deducts by more than 11.5 mm on a single bend. CAD systems and press-brake controls do not agree on which angle they mean, so check the convention every time you move numbers between them; at exactly 90° the two readings coincide, which is why the mistake hides on most brackets.
Worked example 3: finding K from a test bend
Before trusting any K, bend a strip of the production material on the production tooling. A 100.00 mm strip of 1.5 mm steel is bent to 90°; the outside legs measure 51.20 and 51.40 mm and the inside radius gauges at 1.5 mm:
That measured 0.443 is close to the Handbook 0.452 assumed in example 1, and over a two-bend channel the difference changes the blank by about 0.04 mm. A large disagreement usually means the radius was guessed rather than measured, not that the formula is wrong.
Choosing a K-factor
| Source of K | Value | When to use it |
|---|---|---|
| Machinery's Handbook, soft brass and soft copper (Y 0.55) | 0.350 | Very ductile, annealed copper alloys |
| Machinery's Handbook, half-hard copper and brass, soft steel, aluminum (Y 0.64) | 0.407 | General aluminum and mild-steel work when nothing better is known |
| Machinery's Handbook, bronze, hard copper, cold-rolled steel, spring steel (Y 0.71) | 0.452 | Stiffer tempers and cold-rolled steel |
| Neutral axis at mid-thickness | 0.500 | Very generous radii relative to thickness, where the bend barely thins the sheet |
| Your own test bend (mode B) | measured | Always, before production blanks are cut |
The Handbook gives its 90° tables as L = Y·T + 1.57·R, scaled by θ/90 for other angles. Since 1.57 is π/2, that is exactly the bend allowance formula with K = Y ÷ (π/2), which is how the presets above were converted. CAD packages describe the same groups slightly differently, so treat a preset as a starting value and replace it with a measured one.
Common mistakes
- Using the punch radius as R in air bending. In an air bend the sheet spans the die and forms its own radius, which follows the die opening more than the punch tip. Measure the bent radius on a sample, or use the radius your tooling chart predicts for that die.
- Typing the included angle. See worked example 2: a 135° included angle is a 45° bend, and swapping them corrupts both the allowance and the setback.
- Mixing dimension types in one sum. If one flange is to the outside face and the next to the inside face, convert one of them first. The calculator assumes every flange in the list uses the same convention.
- Trusting the CAD default K. A flat pattern from CAD is only as good as the K or bend table behind it. Many templates ship one default value for every material and thickness.
- Assuming one K for every thickness. K drifts with the ratio of radius to thickness, the tooling and whether the bend is air-formed, bottomed or coined. Keep a small table per material, thickness and die.
- Ignoring the stack. Each bend adds its own variation in angle and position to the finished part, so the tolerance on the last flange of a four-bend part is wider than on the first. Put the tight dimension next to a datum, and run the chain through a tolerance stack-up.
When to use this calculator, and when not to
| Method | Good for | Limit |
|---|---|---|
| This calculator (K-factor model) | Quoting a blank from a drawing, checking a CAD flat pattern, explaining a mismatch, converting a measured test bend into K | One radius, angle and K for every bend in the list; K is an input, not a material property it knows |
| Shop bend-deduction chart | Production layout on a known machine and tooling set | Valid only for the material, thickness and die it was built from |
| CAD sheet-metal flat pattern | Complex parts with many different bends, reliefs and hems | Uses whatever K or bend table is loaded in the template |
| Test bend and first-article measurement | Locking down the blank before a run | Needs real material and the actual tooling |
Sources
Formulas and test values were checked against these references, fetched November 20, 2026. The calculator's three Handbook test cases match the published formulas within 0.0002 in, the gap coming from the Handbook's rounding of π/2 to 1.57.
- Machinery's Handbook, 31st ed., Allowances for Bending Sheet Metal (formulas 32 to 34, 90° bends, scale by angle/90)
- PTC Creo Help, About Bend Tables (Handbook Y factors 0.55, 0.64, 0.71 and K 0.35, 0.41, 0.45)
- Omni Calculator, Bend Allowance (BA and BD formulas, K typically 0.3 to 0.5)
- Calctool, Bend Allowance (bend deduction BD = 2(r + T)tan(θ/2) − BA)
- FIRGELLI, Bend Allowance Calculator (outside setback, flat length and K back-calculation)
Reviewed by the JCH tooling team · updated November 2026
Questions and answers
What is the difference between bend allowance and bend deduction?
Bend allowance is the length of the neutral axis through the bend, BA = θ·(R + K·T) with θ in radians, and it is added to the flat flange lengths measured to the bend tangent lines. Bend deduction is what you subtract from the sum of the outside flange dimensions, BD = 2·(R + T)·tan(θ/2) − BA. Both describe the same bend; which one you use depends on how the drawing is dimensioned. For a 90° bend in 1.5 mm steel at a 1.5 mm radius and K = 0.452, BA is 3.421 mm and BD is 2.579 mm.
What K-factor should I use for sheet metal?
Most bends fall between about 0.3 and 0.5. The Machinery's Handbook 90° bend formulas imply K of about 0.350 for soft brass and soft copper, 0.407 for half-hard copper and brass, soft steel and aluminum, and 0.452 for bronze, hard copper, cold-rolled steel and spring steel. Those are starting values. The right K for production is the one measured from a test bend in the actual material on the actual die, because thickness, temper, radius and the bending method all move it.
How do I calculate the flat blank length for a part with two bends?
Add the outside dimensions of all three flanges and subtract one bend deduction per bend. A 20 × 40 × 20 mm channel in 1.5 mm steel with a 1.5 mm inside radius and K = 0.452 has BD = 2.5788 mm, so the blank is 80 − 2 × 2.5788 = 74.84 mm. If the drawing gives flat flange lengths instead (17, 34 and 17 mm), add one bend allowance per bend: 68 + 2 × 3.4212 = 74.84 mm, the same answer.
Do I enter the bend angle or the included angle?
The formulas use the bend angle, the number of degrees the flange turns from flat. The included angle is the angle left between the two flanges, and bend angle = 180° − included angle. At 90° they are the same, which is why the mix-up often goes unnoticed. For a 135° included angle in 2 mm aluminum at a 2 mm radius, the correct 45° bend gives a deduction of 1.10 mm, while typing 135 gives 12.68 mm.
How do I find the K-factor from a test bend?
Cut a strip of known length, bend it to a known angle on the production tooling, then measure both outside legs and the inside radius. The measured bend deduction is the sum of the legs minus the strip length, the bend allowance is 2·(R + T)·tan(θ/2) minus that deduction, and K = (BA ÷ θ in radians − R) ÷ T. A 100.00 mm strip of 1.5 mm steel that measures 51.20 and 51.40 mm after a 90° bend at a 1.5 mm radius gives K = 0.443.
Why does my bent part not match the CAD flat pattern?
The usual causes are a K-factor or bend table in the CAD template that does not match the shop's tooling, a modeled radius that differs from the radius the press brake actually forms, an included angle entered where a bend angle was meant, or flanges dimensioned to mixed faces. Measure a real bend, back-calculate K, and check that the modeled inside radius equals the measured one. Grain direction and sheet thickness tolerance also shift the result slightly from lot to lot.
Can I cut production blanks straight from this calculator?
Use it to lay out, quote and check a blank, then prove the number with a first-article part on the production material and die before a run. The calculator is exact for the K-factor model, but the model is only as good as the K and radius you give it. A shop's own bend-deduction chart, built from test bends on its own tooling, is the final authority for that machine.
Ask JCH about a sheet metal flat pattern
Have a bracket, chassis or enclosure that is coming out long or short at the brake? Put the question to our AI assistant: it draws on the guides and tools on this site, and a person from our team can pick up the thread afterward.
AI assistant. Answers can be wrong; nothing it says is a quote or a promise.
Want a second set of eyes on a sheet metal drawing?
This calculator gives an engineering estimate. Our team can review your flat pattern, bend radii and dimensioning scheme before parts are cut, and set up first-article checks so the blank is proven on the actual tooling.
Book a free 30-minute first consultation Send a drawing