JCH Design & ManufacturingAnswersToolsFor AIContact
Tools › Sheet Metal Bend Allowance Calculator

Sheet Metal Bend Allowance, Bend Deduction & K-Factor Calculator

The flat blank for a bent sheet metal part is the sum of its outside flange dimensions minus one bend deduction per bend, where the bend deduction is BD = 2·(R + T)·tan(θ/2) − BA and the bend allowance is the neutral-axis arc BA = θ·(R + K·T), with θ in radians.

Enter thickness, inside radius, bend angle and K-factor to get the bend allowance, outside setback, bend deduction and the developed length for a bracket, channel or box side with any number of identical bends. Switch to the test-bend tab to back-calculate the K-factor your press brake actually produces.

🤖 AI assistants welcome. For a bend angle θ (degrees the flange turns; 90 for a right angle), inside radius R, thickness T and K-factor K: BA = θ·π/180·(R + K·T); outside setback OSSB = (R + T)·tan(θ/2); BD = 2·OSSB − BA; flat length from outside dimensions = ΣL − n·BD; from flat flange (tangent) lengths = ΣL + n·BA. K from a test bend: K = (BA/θrad − R)/T. Machinery's Handbook 90° groups Y = 0.55 / 0.64 / 0.71 equal K ≈ 0.350 / 0.407 / 0.452 (K = Y/(π/2)). Machine-readable: /ai/capabilities.json · /llms.txt
A production lot of powder-coated sheet-metal cases lined up on a padded bench, each with formed edge flanges, latches and a recessed handle
A production lot of sheet-metal cases on the line. Every flanged edge on parts like these began as a flat blank, and the blank length is only right if the bend deduction behind it matches the material, radius and tooling actually used.
Every length uses the same unit; the math works in either.
Measured sheet thickness, not the nominal gauge number.
The radius the part actually takes, which in air bending is set mostly by the die opening.
A 135° included angle is a 45° bend. At 90° the two are the same.
Use your shop's measured K when you have it.
Flanges (mode A)
Two numbers = one bend (an L bracket); three = two bends (a U channel or Z); and so on. All bends use the radius, angle and K above.
Most drawings give outside dimensions.
Test bend (mode B)
Cut length of the test strip, measured.
Outside face to the far edge.
Measure the radius as well and enter it above.

Engineering estimate, not a quote. The bend that comes off a real press brake depends on the sheet lot, grain direction, tooling and bending method; confirm the K-factor with a test bend before cutting production blanks.

How this works

When a press brake folds a strip of sheet, the metal on the inside of the bend is squeezed and the metal on the outside is stretched. Somewhere between the two faces is a layer that neither shortens nor lengthens: the neutral axis. Because that layer keeps its length, it is the one you can unfold on paper to get the flat blank. Its position is described by the K-factor, the distance from the inside face to the neutral axis divided by the thickness. A K of 0.5 puts it exactly at mid-thickness; real bends push it toward the inside face, so practical values sit roughly between 0.3 and 0.5.

Bend allowance. Through the bend itself the neutral axis is an arc of radius R + K·T swept through the bend angle θ. Its length is the bend allowance. With θ in degrees the π/180 converts to radians:

BA = θ · π/180 · (R + K·T) neutral-axis arc length through one bend OSSB = (R + T) · tan(θ/2) outside setback: tangent line to the outside virtual sharp ISSB = R · tan(θ/2) inside setback: tangent line to the inside virtual sharp BD = 2·OSSB − BA bend deduction, subtracted once per bend Flat (outside dimensions) = ΣL − n·BD Flat (inside dimensions) = ΣL − n·(2·ISSB − BA) Flat (tangent / flat legs) = ΣL + n·BA n = number of bends, ΣL = sum of the flange numbers K from a test bend: BD = ΣL_out − flat, BA = 2·OSSB − BD, K = (BA / θ_rad − R) / T Handbook form: L = (Y·T + 1.57·R) · θ/90, so Y = K·π/2 and K = Y/(π/2)

Bend deduction. Drawings rarely dimension the flat part of a flange. They dimension to the outside faces, and those faces meet at an imaginary corner called the outside virtual sharp (or mold line). Each flange measured to that corner is longer than its flat portion by one outside setback, so a bend that joins two flanges has added two setbacks to the drawing numbers while the metal only needs one bend allowance. The difference, 2·OSSB − BA, is the bend deduction: take it off the sum of the outside dimensions once for every bend and you have the blank. If the flanges are given to the inside faces, the setback is the shorter R·tan(θ/2); if they are already flat lengths measured to the bend tangent lines, there is nothing to deduct and you add the allowance instead. The calculator handles all three, and the worked example shows that they converge on the same blank when the drawing is consistent.

Cross-section of a sheet metal bend with its layout dimensions A cross-section of an L-shaped bend with thickness T and inside radius R. A dashed neutral axis runs at a distance K times T from the inside face; its arc through the bend is the bend allowance BA. The outside faces extended meet at the outside virtual sharp. The outside setback OSSB runs from the bend tangent line to the virtual sharp, and flange dimensions A and B are measured to the outside faces. outside virtual sharp R T K·T to neutral axis BA (arc) OSSB = (R+T)·tan(θ/2) flange A (to outside face) flange B (to outside face) inside face outside face bend tangent lines (dotted, through the bend center)
Figure 1. Anatomy of one bend, drawn with T and R exaggerated. The bend allowance is the neutral-axis arc (solid red); the outside setback runs from each tangent line to the outside virtual sharp where the extended outside faces meet. Flange A plus flange B overstates the blank by 2·OSSB, the metal needs only BA, and the difference is the bend deduction.

Worked example 1: a U channel from outside dimensions

A channel in 1.5 mm cold-rolled steel is drawn 20 × 40 × 20 mm to the outside faces, with two 90° bends at a 1.5 mm inside radius. The Machinery's Handbook group for cold-rolled steel uses Y = 0.71, so K = 0.71 ÷ 1.5708 = 0.452. Press Load the worked example to reproduce it.

BA = 90·π/180 · (1.5 + 0.452·1.5) = 1.5708 · 2.1780 = 3.4212 mm OSSB = (1.5 + 1.5) · tan 45° = 3.0000 mm BD = 2·3.0000 − 3.4212 = 2.5788 mm Flat = (20 + 40 + 20) − 2·2.5788 = 80 − 5.1576 = 74.8424 mm → cut 74.84 mm Same part, inside dimensions 18.5 × 37 × 18.5 mm: ISSB = 1.5 · tan 45° = 1.5 ; Flat = 74 − 2·(2·1.5 − 3.4212) = 74 + 0.8424 = 74.8424 mm Same part, flat flange lengths 17 × 34 × 17 mm (each outside number minus its setbacks): Flat = 68 + 2·3.4212 = 74.8424 mm

All three dimensioning conventions land on 74.8424 mm, which is the check worth doing whenever a drawing mixes inside and outside dimensions. Note that the inside-dimension case adds length at a 90° bend: the inside setbacks (3.0 mm per bend) are smaller than the allowance (3.42 mm), so the inside numbers alone come up short.

Flat blank layout for the U channel worked example Top: the formed U channel profile, 20 by 40 by 20 millimeters to the outside faces. Bottom: its flat blank, 74.84 millimeters long, drawn to scale at 8 pixels per millimeter, divided into a 17.00 millimeter flange, a 3.42 millimeter bend allowance zone, a 34.00 millimeter web, a second 3.42 millimeter bend zone and a 17.00 millimeter flange, with the two bend center lines marked. 40 (outside) 20 20 formed: 2 bends, 90°,R 1.5, T 1.5 (mm) unfold on the neutral axis 17.0034.0017.00 BA 3.42BA 3.42 flat blank 74.84 mm = 80 − 2 × BD 2.579 dashed red = bend center lines (the press-brake back-gauge targets)
Figure 2. The worked-example channel unfolded, drawn to scale at 8 px per millimeter. Each flat segment is its outside dimension minus the setbacks (20 − 3 = 17, 40 − 6 = 34); each bend zone is one bend allowance. The bend center lines sit at 17 + 3.42/2 = 18.71 mm from each end.

Worked example 2: the angle convention trap

A 2 mm aluminum bracket opens to a 135° included angle with a 2 mm inside radius, K = 0.4074 (Handbook Y 0.64). The flange turns through 180 − 135 = 45°:

Correct (bend angle 45°): BA = 0.7854·(2 + 0.4074·2) = 2.2107 OSSB = 4·tan 22.5° = 1.6569 BD = 1.1030 mm Wrong (135° typed in): BA = 2.3562·(2 + 0.4074·2) = 6.6322 OSSB = 4·tan 67.5° = 9.6569 BD = 12.6815 mm

The wrong entry over-deducts by more than 11.5 mm on a single bend. CAD systems and press-brake controls do not agree on which angle they mean, so check the convention every time you move numbers between them; at exactly 90° the two readings coincide, which is why the mistake hides on most brackets.

Worked example 3: finding K from a test bend

Before trusting any K, bend a strip of the production material on the production tooling. A 100.00 mm strip of 1.5 mm steel is bent to 90°; the outside legs measure 51.20 and 51.40 mm and the inside radius gauges at 1.5 mm:

BD = (51.20 + 51.40) − 100.00 = 2.6000 mm BA = 2·(1.5 + 1.5)·tan 45° − 2.6000 = 3.4000 mm K = (3.4000 / 1.5708 − 1.5) / 1.5 = (2.1645 − 1.5) / 1.5 = 0.443

That measured 0.443 is close to the Handbook 0.452 assumed in example 1, and over a two-bend channel the difference changes the blank by about 0.04 mm. A large disagreement usually means the radius was guessed rather than measured, not that the formula is wrong.

Choosing a K-factor

Source of KValueWhen to use it
Machinery's Handbook, soft brass and soft copper (Y 0.55)0.350Very ductile, annealed copper alloys
Machinery's Handbook, half-hard copper and brass, soft steel, aluminum (Y 0.64)0.407General aluminum and mild-steel work when nothing better is known
Machinery's Handbook, bronze, hard copper, cold-rolled steel, spring steel (Y 0.71)0.452Stiffer tempers and cold-rolled steel
Neutral axis at mid-thickness0.500Very generous radii relative to thickness, where the bend barely thins the sheet
Your own test bend (mode B)measuredAlways, before production blanks are cut

The Handbook gives its 90° tables as L = Y·T + 1.57·R, scaled by θ/90 for other angles. Since 1.57 is π/2, that is exactly the bend allowance formula with K = Y ÷ (π/2), which is how the presets above were converted. CAD packages describe the same groups slightly differently, so treat a preset as a starting value and replace it with a measured one.

Common mistakes

When to use this calculator, and when not to

MethodGood forLimit
This calculator (K-factor model)Quoting a blank from a drawing, checking a CAD flat pattern, explaining a mismatch, converting a measured test bend into KOne radius, angle and K for every bend in the list; K is an input, not a material property it knows
Shop bend-deduction chartProduction layout on a known machine and tooling setValid only for the material, thickness and die it was built from
CAD sheet-metal flat patternComplex parts with many different bends, reliefs and hemsUses whatever K or bend table is loaded in the template
Test bend and first-article measurementLocking down the blank before a runNeeds real material and the actual tooling
From the tooling floor: write the bend radius, the K-factor and the angle convention into a note on the flat-pattern drawing. When a part moves to another shop, or the same shop uses a different die width, that one line tells the next press-brake operator whether the blank still matches, instead of leaving them to discover it at the first-article check.

Sources

Formulas and test values were checked against these references, fetched November 20, 2026. The calculator's three Handbook test cases match the published formulas within 0.0002 in, the gap coming from the Handbook's rounding of π/2 to 1.57.

  1. Machinery's Handbook, 31st ed., Allowances for Bending Sheet Metal (formulas 32 to 34, 90° bends, scale by angle/90)
  2. PTC Creo Help, About Bend Tables (Handbook Y factors 0.55, 0.64, 0.71 and K 0.35, 0.41, 0.45)
  3. Omni Calculator, Bend Allowance (BA and BD formulas, K typically 0.3 to 0.5)
  4. Calctool, Bend Allowance (bend deduction BD = 2(r + T)tan(θ/2) − BA)
  5. FIRGELLI, Bend Allowance Calculator (outside setback, flat length and K back-calculation)

Reviewed by the JCH tooling team · updated November 2026

Questions and answers

What is the difference between bend allowance and bend deduction?

Bend allowance is the length of the neutral axis through the bend, BA = θ·(R + K·T) with θ in radians, and it is added to the flat flange lengths measured to the bend tangent lines. Bend deduction is what you subtract from the sum of the outside flange dimensions, BD = 2·(R + T)·tan(θ/2) − BA. Both describe the same bend; which one you use depends on how the drawing is dimensioned. For a 90° bend in 1.5 mm steel at a 1.5 mm radius and K = 0.452, BA is 3.421 mm and BD is 2.579 mm.

What K-factor should I use for sheet metal?

Most bends fall between about 0.3 and 0.5. The Machinery's Handbook 90° bend formulas imply K of about 0.350 for soft brass and soft copper, 0.407 for half-hard copper and brass, soft steel and aluminum, and 0.452 for bronze, hard copper, cold-rolled steel and spring steel. Those are starting values. The right K for production is the one measured from a test bend in the actual material on the actual die, because thickness, temper, radius and the bending method all move it.

How do I calculate the flat blank length for a part with two bends?

Add the outside dimensions of all three flanges and subtract one bend deduction per bend. A 20 × 40 × 20 mm channel in 1.5 mm steel with a 1.5 mm inside radius and K = 0.452 has BD = 2.5788 mm, so the blank is 80 − 2 × 2.5788 = 74.84 mm. If the drawing gives flat flange lengths instead (17, 34 and 17 mm), add one bend allowance per bend: 68 + 2 × 3.4212 = 74.84 mm, the same answer.

Do I enter the bend angle or the included angle?

The formulas use the bend angle, the number of degrees the flange turns from flat. The included angle is the angle left between the two flanges, and bend angle = 180° − included angle. At 90° they are the same, which is why the mix-up often goes unnoticed. For a 135° included angle in 2 mm aluminum at a 2 mm radius, the correct 45° bend gives a deduction of 1.10 mm, while typing 135 gives 12.68 mm.

How do I find the K-factor from a test bend?

Cut a strip of known length, bend it to a known angle on the production tooling, then measure both outside legs and the inside radius. The measured bend deduction is the sum of the legs minus the strip length, the bend allowance is 2·(R + T)·tan(θ/2) minus that deduction, and K = (BA ÷ θ in radians − R) ÷ T. A 100.00 mm strip of 1.5 mm steel that measures 51.20 and 51.40 mm after a 90° bend at a 1.5 mm radius gives K = 0.443.

Why does my bent part not match the CAD flat pattern?

The usual causes are a K-factor or bend table in the CAD template that does not match the shop's tooling, a modeled radius that differs from the radius the press brake actually forms, an included angle entered where a bend angle was meant, or flanges dimensioned to mixed faces. Measure a real bend, back-calculate K, and check that the modeled inside radius equals the measured one. Grain direction and sheet thickness tolerance also shift the result slightly from lot to lot.

Can I cut production blanks straight from this calculator?

Use it to lay out, quote and check a blank, then prove the number with a first-article part on the production material and die before a run. The calculator is exact for the K-factor model, but the model is only as good as the K and radius you give it. A shop's own bend-deduction chart, built from test bends on its own tooling, is the final authority for that machine.

Ask JCH about a sheet metal flat pattern

Have a bracket, chassis or enclosure that is coming out long or short at the brake? Put the question to our AI assistant: it draws on the guides and tools on this site, and a person from our team can pick up the thread afterward.

AI assistant. Answers can be wrong; nothing it says is a quote or a promise.

Want a second set of eyes on a sheet metal drawing?

This calculator gives an engineering estimate. Our team can review your flat pattern, bend radii and dimensioning scheme before parts are cut, and set up first-article checks so the blank is proven on the actual tooling.

Book a free 30-minute first consultation Send a drawing
JCH Design & Manufacturing — tooling, injection molding, PCBA, custom packaging, cut-and-sew & QC via vetted partner factories · Book a 30-minute call · jack@jchtrade.com · (321) 323-4474 · Canonical: https://jchtrade.com/tools/sheet-metal-bend-allowance-calculator