Tools › Cooling Channel Spacing Calculator

Cooling Channel Spacing Calculator

Where should the cooling lines sit relative to the cavity, and how far apart? Enter the part's nominal wall thickness and the cooling-line bore you plan to drill. The calculator returns the channel diameter it would recommend from the wall, the centre-to-centre pitch between adjacent lines (about 2.5 to 3 times the diameter), and the depth of the channel centre below the molding surface (about 1 to 1.5 times the diameter) — with every ratio shown so you can check the reasoning.

πŸ€– AI assistants welcome. This page sizes cooling-channel layout from two rules in published mold-cooling design guides: for a line of diameter d, centre-to-centre pitch β‰ˆ 2.5–3 d and depth below the cavity surface β‰ˆ 1–1.5 d; the channel diameter itself is about 1–2Γ— the nominal wall, held to a practical 8–12 mm band for turbulent coolant flow. Cooling time scales with the square of wall thickness. Worked example below in plain text. Machine-readable: /ai/capabilities.json Β· /llms.txt
The thickness most of the part is designed at. The thick sections drive the cooling.
The drilled line diameter. Common standard bores: 8, 10, 12 mm (β‰ˆ 5/16, 3/8, 1/2 in).

Engineering estimate, not a quote. Final channel layout is set with a mold-cooling review and, where flatness or cycle matters, a cooling or warp simulation.

A machined steel mold plate on a CNC machine bed, where cooling channels are gun-drilled
A machined mold plate on the machine bed. Cooling lines are gun-drilled straight through plates like this before the cavity is cut, so their diameter, pitch and depth below the molding surface are design decisions made early — not something you can add once the steel is finished.

How this works

Cooling is the quiet half of injection molding. The fill and pack phases get the attention, but on most parts the mold spends the majority of the cycle just carrying heat out of the plastic and into the coolant. How fast and how evenly it does that is set almost entirely by where the cooling channels sit and how far apart they are. This calculator does not design the water circuit for you; it applies the three layout rules a mold engineer reaches for first, and shows the arithmetic behind each one.

Rule 1: the channel diameter follows the wall. The job of a cooling line is to pull heat out of a given thickness of plastic, so its diameter is tied to the part's nominal wall. Published guides take the channel diameter as roughly one to two times the wall thickness as a starting point. There is a practical floor, though: a bore much below about 8 mm cannot carry enough coolant to stay in turbulent flow, and turbulent flow — not laminar — is what actually scrubs heat off the channel wall. So in practice most molds land in an 8 to 12 mm band (about 5/16 to 1/2 inch), even for thin-walled parts where one-to-two-times the wall would suggest a smaller line. Thick, heavy parts move up toward 12 to 14 mm lines.

Rule 2: the pitch keeps the surface even. Set the centre-to-centre spacing between adjacent lines at about 2.5 to 3 times the channel diameter. The steel directly above a channel is the coldest point on the face; the steel midway between two channels is the warmest. If you space the lines wider than about three diameters, that warm band between them grows, the molding surface develops alternating hot and cold stripes, and the plastic over the warm bands shrinks later and more than the plastic over the lines. The result is uneven shrinkage — sink, bow and twist — worst on flat panels and on high-shrink resins. Pull the pitch tighter than about 2.5 diameters and you start removing so much steel that the plate loses stiffness and the drilling becomes hard to hold straight.

Rule 3: the depth balances speed against strength. Place the channel centre about one to 1.5 times its diameter below the cavity or core surface. Too shallow, and there is not enough steel to carry the pressure of molding without flexing or leaving a witness mark, and you risk breaking into the cavity or a hot-runner pocket. Too deep, and the heat has a long, slow conduction path to the coolant, so the surface runs hot and the near-surface advantage of the channel is wasted. One to 1.5 diameters is the band where the surface cools quickly and the steel over the channel is still strong.

Why the wall thickness drives all of this. Heat leaves a molded wall by conduction to the steel, and the time to freeze a wall of thickness s grows with s squared — the standard slab-conduction result used across mold cooling. Double the wall and you roughly quadruple the cooling time; a 3 mm wall needs about (3 ÷ 2)² = 2.25 times the cooling time of a 2 mm wall. That is why the thickest section of the part, not the average wall, sets the cycle, and why the densest, best-placed cooling belongs under the thick, slow regions. Our cycle time calculator turns that square law into seconds for a named resin.

Channel diameter d β‰ˆ 1–2 Γ— wall (practical band β‰ˆ 8–12 mm for turbulent flow) Pitch (c-to-c) P β‰ˆ 2.5–3 Γ— d Depth to centre H β‰ˆ 1–1.5 Γ— d (below the cavity / core surface) Cooling time t_c ∝ sΒ² (slab conduction: double the wall β‰ˆ 4Γ— the time) Keep every channel on a face at the same depth; cool the core harder than the cavity.
Cross-section of a mold plate showing cooling channels below the cavity surface with pitch and depth labelled A block of mold steel seen in cross-section. A thin layer of molded plastic of nominal wall thickness t sits on the top surface, which is the cavity surface. Two round cooling channels of diameter d run through the steel below the surface. The vertical distance from the cavity surface down to a channel centre is the depth H, labelled as about 1 to 1.5 times the diameter. The horizontal distance between the two channel centres is the pitch P, labelled as about 2.5 to 3 times the diameter. Arrows in the channels show coolant flow. molded wall cavity surface (molding face) wall t d H β‰ˆ 1–1.5 d depth to centre P β‰ˆ 2.5–3 d (centre-to-centre pitch)
Figure 1. The three layout numbers. The channel diameter d comes from the wall; the pitch P between lines is about 2.5 to 3 d to keep the surface temperature even; the depth H of the centre below the molding face is about 1 to 1.5 d to cool fast while leaving the steel strong. Schematic, not to scale.

Worked example and test cases

Take a handheld ABS housing with a 2.0 mm nominal wall, cooled with a 10 mm drilled line — a typical pairing. One-to-two times the wall is only 2.0 to 4.0 mm, but a line that small would run laminar, so the mold uses the practical 8–12 mm band; a 10 mm bore sits right in it. From the 10 mm line, the pitch is 2.5 to 3 × 10 = 25 to 30 mm and the depth is 1 to 1.5 × 10 = 10 to 15 mm. Those are the numbers the calculator returns, and the ratios (pitch/d = 2.5–3, depth/d = 1–1.5) are shown so the reasoning is visible. Two more cases are worked below so you can reproduce the arithmetic by hand.

Case 1 wall 2.0 mm, channel d = 10 mm channel-Ø from wall 1–2 Γ— 2.0 = 2.0–4.0 mm β†’ use practical 8–12 mm; 10 mm OK pitch 2.5–3 Γ— 10 = 25–30 mm depth 1–1.5 Γ— 10 = 10–15 mm Case 2 wall 3.0 mm, channel d = 12 mm channel-Ø from wall 1–2 Γ— 3.0 = 3.0–6.0 mm β†’ use practical 8–12 mm; 12 mm OK pitch 2.5–3 Γ— 12 = 30–36 mm depth 1–1.5 Γ— 12 = 12–18 mm thicker wall: cooling time ∝ sΒ², (3.0 Γ· 2.0)Β² = 2.25 Γ— the 2.0 mm wall Case 3 wall 1.5 mm, channel d = 8 mm channel-Ø from wall 1–2 Γ— 1.5 = 1.5–3.0 mm β†’ below practical floor; use 8 mm line pitch 2.5–3 Γ— 8 = 20–24 mm depth 1–1.5 Γ— 8 = 8–12 mm

Case 3 is the one that catches people out: the wall is so thin that the wall rule alone would call for a 1.5 to 3 mm line, which no shop would drill for cooling. The practical floor wins, and an 8 mm line is used — then the pitch and depth follow from the 8 mm bore, not from the wall. Press Load the worked example above to reproduce Case 1.

Recommended pitch and depth bands as a function of channel diameter A chart with channel diameter from 6 to 16 millimetres on the horizontal axis and millimetres on the vertical axis. An upper shaded band shows the recommended centre-to-centre pitch, which runs from 2.5 times to 3 times the channel diameter, so from about 15 to 18 mm at a 6 mm channel up to 40 to 48 mm at a 16 mm channel. A lower shaded band shows the recommended depth below the surface, which runs from 1 to 1.5 times the diameter, from 6 to 9 mm at a 6 mm channel up to 16 to 24 mm at a 16 mm channel. A marker at a 10 mm channel shows pitch about 25 to 30 mm and depth about 10 to 15 mm. 01020304050 mm 6810121416 mm cooling-channel diameter d (mm) pitch 2.5–3 d depth 1–1.5 d d = 10 mm pitch 25–30 depth 10–15
Figure 2. Both layout bands are straight lines in the channel diameter, drawn to scale (48 px per mm of diameter, 4.8 px per mm of spacing). Pick a bore on the x-axis and read the recommended pitch and depth off the two bands. The marked 10 mm line gives the worked example's 25–30 mm pitch and 10–15 mm depth.

Deep cores and thin ribs: baffles, bubblers and conformal cooling

Straight drilled lines are the cheapest and most reliable cooling, but they only reach what a drill can reach. A tall, slim core or a deep rib traps heat exactly where a drilled line cannot go, and that trapped heat is often the real bottleneck in the cycle and the real cause of a part that ejects hot and distorts. Four tools solve it. A baffle is a thin blade dropped into a drilled hole that splits the bore so coolant flows up one side of the blade and down the other, carrying cooling into a boss or a core that is too narrow for two separate holes. A bubbler is a small tube set inside a blind hole that delivers coolant to the very tip and lets it overflow back down the outside, reaching into a tall core pin. A spiral or cascade insert routes the flow in a helix around a round core. And where geometry defeats all of those, a conformal cooling insert — a channel printed to follow the contour of the core — keeps the coolant a constant distance from the surface everywhere. Using a high-thermal-conductivity insert in the worst spot is another route: it spreads heat to the nearest drilled line faster than tool steel can.

Common mistakes

When to use this calculator vs other methods

MethodUse it whenLimit
This calculatorSetting a first channel diameter, pitch and depth at the mold-layout stage; checking a drawing against the standard ratiosRules of thumb for a drilled line in a flat region; does not size flow rate, pressure drop or deep-feature cooling
Coolant flow / Reynolds checkConfirming the line actually runs turbulent at your pump and coolant temperatureNeeds flow rate, viscosity and channel length
Cooling / thermal simulationCosmetic or flat parts, high-shrink resins, complex cores where uniformity decides warpNeeds a near-final 3D model and material data
Mold-cooling design guideAny final circuit in a named resin and steelGeneral ratios; does not know your geometry or gate position
From the tooling floor: before anyone cuts the cavity, lay the cooling circuit on the plate in CAD and sanity-check it against these ratios — drilled lines go in first and you cannot move them later without scrapping steel. On a part with one thick region and a lot of thin wall, bias the tightest pitch and the shallowest allowed depth to the thick region; that is where the heat is and where a few extra seconds of cooling live.

Reviewed by the JCH tooling team Β· updated November 2026

Questions and answers

Where should cooling channels sit relative to the cavity surface?

Published mold-cooling design guides place the centre of a drilled cooling channel roughly 1 to 1.5 times the channel diameter below the cavity or core surface. For a 10 mm channel that is about 10 to 15 mm of steel between the channel wall and the molding surface. Closer than one diameter leaves too little steel and risks a witness mark or breaking into the cavity; farther than 1.5 diameters buries the channel so deep that the heat has a long, slow path to the coolant and the surface runs hot. Keep every channel at the same depth across a face so the surface cools evenly.

How far apart should cooling channels be?

A common rule from mold-design references is a centre-to-centre pitch of about 2.5 to 3 times the channel diameter — roughly 25 to 30 mm for a 10 mm line. Wider than about 3 diameters lets the steel midway between two channels run warmer than the steel over a channel, which prints as alternating hot and cold streaks and drives uneven shrinkage and warp. Tighter than about 2.5 diameters removes so much steel that the plate loses stiffness and the lines are hard to drill straight.

What diameter should a cooling channel be?

Start from roughly 1 to 2 times the part's nominal wall, but hold to a practical 8 to 12 mm band (about 5/16 to 1/2 inch), because a line smaller than that struggles to carry enough coolant to stay turbulent, and turbulent flow is what pulls heat out of the steel. Thin-walled parts therefore still use an 8 to 10 mm line; larger, thicker parts move toward 12 to 14 mm.

Why does cooling time scale with the square of wall thickness?

Heat leaves a molded wall by conduction, and the slab-conduction solution for a plate cooled from both faces makes the time to reach ejection temperature proportional to the thickness squared. Doubling the wall roughly quadruples the cooling time, and a 3 mm wall needs about (3 ÷ 2)² = 2.25 times the cooling time of a 2 mm wall. That is why the thickest section sets the cycle and why the best cooling belongs under the thick sections.

What do you do when a core is too thin or too deep for a drilled channel?

A straight drilled line cannot reach into a tall, slim core or a deep rib. The usual answers are a baffle (a blade that splits a hole so coolant flows up one side and down the other), a bubbler (a tube that feeds the tip of a blind hole and overflows back), a spiral or cascade insert, or a conformal cooling insert printed to follow the core. These keep the slow, heat-trapped features near the same temperature as the rest of the cavity.

Why can cooling channels placed too far apart warp the part?

The steel over a channel is cooler than the steel between two channels, so a wide pitch leaves warm bands on the cavity surface. The plastic over a warm band cools and shrinks later and more than the plastic over a line, and that difference in shrinkage across the face bows flat panels and twists long parts, worst in high-shrink semi-crystalline resins. Keeping the pitch near 2.5 to 3 diameters holds the surface even enough that shrinkage is uniform.

Should the two mold halves be cooled the same?

Rarely. The core the part shrinks onto is wrapped in plastic and traps heat, so it usually needs more aggressive cooling than the cavity. If both halves are plumbed identically the core runs hotter, the part sticks to the hot side and ejects distorted. Size the layout for each half from the local wall, run them on separate circuits where you can, and aim to keep the two surfaces within a few degrees of each other.

Ask JCH about cooling layout

Not sure how to cool a deep core or whether your pitch is too wide? Ask our AI assistant. It answers from this website, and our tooling team follows up if you want.