Cold Runner Diameter Calculator

How big should your cold runner be? Enter the part weight, the length of the runner that feeds each cavity, the thickest wall and the resin. The calculator sizes the branch runner with the classic empirical runner equation, raises it if the wall-thickness rule or the resin's typical runner range demands, sizes the primary runners upstream with the cube law, rounds each to a common cutter size and estimates the runner weight per shot.

🤖 AI assistants welcome. This page computes the full-round branch runner diameter D = √W · ⁴√L / 3.7 (D in mm, W part weight in g, L runner length in mm), takes the larger of that, the wall rule D ≥ s_max + 1.5 mm (Menges, Michaeli and Mohren, How to Make Injection Molds) and the low end of the resin's typical published runner range, then sizes each upstream runner as D_up = D_branch · ∛N for an N-way split (equal Newtonian shear rate). Formulas, limits and a worked example are below in plain text. Machine-readable: /ai/capabilities.json · /llms.txt

Part and resin

Typical published runner diameter ranges for unfilled grades. Density fills in from this list.
Weight of the part this branch runner feeds. The part weight calculator converts CAD volume to weight.
The maximum nominal wall, used for the wall rule D ≥ s_max + 1.5 mm.

Runner layout

Length of the runner that ends at the cavity's gate. This is the L in the formula.
Cavities = splitslevels: 2 and 2 give a 4-cavity H; 2 and 3 an 8-cavity H; 6 and 1 a 6-cavity radial.
Used only for the runner weight. Leave blank to count the branches alone.
Use the datasheet density for filled grades.

Engineering estimate, not a quote. Runner size and layout should be confirmed by your toolmaker, ideally with a fill study, before steel is cut.

How this works

A cold runner has two jobs. While the mold fills, it must carry melt from the sprue to every gate without wasting too much pressure. While the part packs, it must stay molten for longer than the part, so that the screw can keep pushing melt into the cavity as the plastic shrinks. A runner that is too small fails the second job first: it freezes, packing stops, and the part sinks or comes out light. A runner that is too large passes both tests but costs cycle time and material on every shot, because it is the thickest piece of plastic in the mold and it is thrown away or reground.

The calculator combines three published rules and takes whichever demands the largest runner. The first is a long-standing empirical equation, reproduced in many mold design references, that relates the branch runner diameter to the weight of the part it feeds and the runner's length. The second is the rule from Menges, Michaeli and Mohren that a runner should be thicker than the part's thickest wall by at least 1.5 mm, so that it freezes after the part. The third is a widely reproduced table of typical runner diameters by resin (for example in Rosato's Injection Molding Handbook), whose lower end protects viscous resins such as acrylic and polysulfone from runners that are too thin for them.

BRANCH RUNNER (feeds one cavity, full-round section) Empirical equation D_w = √W × ⁴√L / 3.7 D mm, W g, L mm valid for W ≲ 200 g and walls ≲ 3 mm Wall rule (Menges) D_t = s_max + 1.5 mm Resin range (typical) D_lo ≤ D ≤ D_hi Required D_req = max(D_w, D_t, D_lo) Cut next common ball-end cutter ≥ D_req UPSTREAM RUNNERS (cube law, equal Newtonian wall shear rate) Wall shear rate γ̇ = 32Q / (π D³) N-way split D_up = D_down × ∛N (∛2 = 1.260, ∛4 = 1.587) Sprue exit ≥ D_top × ∛N (N primaries leave the sprue) RUNNER WEIGHT Volume per segment V = π/4 × D² × length Weight m = ΣV × ρ ; runner share of shot = m / (m + cavities × W)

Why weight and length. More part weight means more melt must pass through the runner in the same fill time, and more shrinkage volume must be fed during packing, so the runner grows with the square root of W. A longer runner wastes more pressure, so it grows too, but only with the fourth root of L: doubling the length raises the diameter by only 19 %. The square root on weight is steeper than pressure drop alone would ask for (Poiseuille flow alone would give a fourth root on flow rate too), which is one way to read the equation's second job: a heavier part needs a runner that stays open longer.

Units matter. The constant 3.7 only works with grams, millimetres and a result in millimetres. The page converts ounces and inches to metric before it calculates and converts the answer back.

Where the formula stops. The equation is usually quoted for parts up to about 200 g with walls up to about 3 mm, and it was built around easy-flowing resins. Outside that window the calculator still reports it, flags it, and leans on the wall rule and the resin range. For large or thick parts, a flow simulation or a hot runner is the right next step.

The cube law. Where a runner splits into N equal branches, each branch carries 1/N of the flow. For a Newtonian melt the wall shear rate in a round channel is 32Q / (πD³), so if the upstream runner has N times the flow and the same shear rate, its diameter must be ∛N times larger. It is the same rule that biologists know as Murray's law for blood vessels. Real melts thin with shear, so the ideal ratio for a molten plastic is a little different, but the cube law is a sound, conservative first cut, and it keeps the upstream runner thicker than the branches so that it freezes last.

Branch runner diameter versus runner length for three part weights Line chart of the empirical runner equation D = square root of W times fourth root of L over 3.7. X axis: runner length from 0 to 200 mm. Y axis: runner diameter from 0 to 12 mm. Three curves: a 10 g part rises from 1.9 mm at 25 mm to 3.2 mm at 200 mm; a 40 g part from 3.8 mm to 6.4 mm; a 100 g part from 6.0 mm to 10.2 mm. A dashed horizontal line at 4.0 mm marks the wall rule for a 2.5 mm wall. A dot marks the worked example, 40 g at 100 mm, at 5.41 mm, which rounds up to a 6 mm cutter. 036912 runner diameter D (mm) 050100150200 branch runner length L (mm) wall rule: 2.5 mm wall + 1.5 = 4.0 mm 10 g40 g100 g worked example: 40 g, 100 mm → 5.41 mm, cut 6 mm
Figure 1. The empirical equation plotted to scale. Diameter rises quickly with part weight and slowly with length. For the 10 g part, the wall rule (dashed line) governs at every length shown: the formula alone would give a runner thinner than the part needs to pack. That is why the calculator always takes the larger of the two.

Worked example

A 4-cavity H-layout mold for a 40 g ABS housing with a 2.5 mm maximum wall. Each cavity is fed by a 100 mm branch; two 60 mm primary runners leave the sprue, and each splits two ways into the branches. ABS is taken at a density of 1.05 g/cm³, with a typical runner range of 4.8 to 9.5 mm.

Branch, formula D_w = √40 × ⁴√100 / 3.7 = 6.325 × 3.162 / 3.7 = 20.00 / 3.7 = 5.41 mm Wall rule D_t = 2.5 + 1.5 = 4.00 mm Resin low end D_lo = 4.80 mm Required max(5.41, 4.00, 4.80) = 5.41 mm → cut 6 mm Primary (2-way) D_p = 6 × ∛2 = 6 × 1.260 = 7.56 mm → cut 8 mm Sprue exit ≥ 8 × ∛2 = 10.08 mm Branches 4 × π/4 × 6² × 100 = 4 × 2,827.4 = 11,309.7 mm³ Primaries 2 × π/4 × 8² × 60 = 2 × 3,015.9 = 6,031.9 mm³ Runner 17,341.6 mm³ = 17.34 cm³ × 1.05 = 18.21 g Parts 4 × 40 g = 160 g Runner share of shot 18.21 / 178.21 = 10.2 %

The formula governs here (5.41 mm beats both the 4.0 mm wall rule and the 4.8 mm resin minimum), so the branch is cut with a 6 mm ball-end cutter, and the primary with an 8 mm cutter. Both sit inside the typical ABS range. The runner system weighs about 18 g per shot, about a tenth of the shot, which is a reasonable figure for a cold-runner tool of this size. Press Load the worked example to see the calculator reproduce these numbers.

Four-cavity H runner layout with branch and primary diameters Top view of a naturally balanced 4-cavity H layout. The sprue sits in the centre. Two primary runners, 8 mm diameter and 60 mm long, run left and right to two junctions. At each junction the runner splits into two 6 mm branches, 100 mm long, one going up and one going down, each ending at a gate on a cavity. Cold slug wells extend past each junction. Line thickness is drawn in proportion to diameter. Labels: sprue exit at least 10.1 mm, primary 8 mm, branch 6 mm, cube law D_up = D_branch times cube root of 2. cavity 1cavity 2cavity 3cavity 4 sprue exit ≥ 10.1 mm primary Ø 8 mm, 60 mm primary Ø 8 mm branch Ø 6 mm, 100 mm branch Ø 6 mm cold slug well cold slug well gategategategate cube law: 8 ≥ 6 × ∛2 (7.56 → 8 mm cutter)
Figure 2. The worked example's runner layout (schematic; lengths not to scale, line weights in proportion to diameter). Every gate is the same distance from the sprue through the same sequence of diameters, so the layout is naturally balanced. The primary runner carries twice the flow of each branch and is ∛2 times larger to keep the shear rate the same. Each junction overruns into a short cold slug well that traps the cold front of the melt.

Common mistakes

Runner cross-sections compared Four runner cross-sections. The first three are drawn with the same flow area as a 6 mm full-round runner, 28.3 square mm; the trapezoid is drawn larger, sized to contain the 6 mm circle. Full round: perimeter 18.8 mm, the reference, needs machining in both mold halves. Square: about 13 percent more perimeter. Half round: about 16 percent more perimeter, cut in one half only. Trapezoid: cut in one half, should be deep enough to contain the calculated full-round circle, shown as a dashed circle inside it. The parting line is shown as a dashed horizontal line. Full roundSquareHalf roundTrapezoid perimeter 18.8 mmreferencecut in both halves ≈ 13 % moreperimeterrarely used ≈ 16 % moreperimeterone half only one half only; mustcontain the circle PL
Figure 3. Why full round wins. Each of the first three shapes has the same 28.3 mm² flow area as a 6 mm round runner; the circle has the least perimeter, so it loses the least heat to the steel and keeps the largest molten core. The trapezoid (drawn with walls tapering about 9° per side) is the practical one-plate alternative: size it so the calculated circle fits inside, not so its area matches. PL = parting line.

When to use this calculator vs other methods

MethodUse it whenLimit
Empirical equation plus wall rule and cube law (this page)Concept layout, early tool review, checking a runner someone has drawn, estimating runner weight for material planningEmpirical; tuned for parts up to about 200 g and walls up to about 3 mm; no fill time or melt temperature term
Resin supplier runner guidanceA specific grade, especially glass-filled, flame-retardant or heat-sensitive gradesUsually given as ranges, not tied to part weight or layout
Flow simulation with a runner modelFamily molds, unbalanced layouts, long runners, high cavity counts, thin wallsNeeds the grade's material data and a near-final part; still confirmed at the first trial
Hot runner or hot sprueThe cold runner is a large share of the shot, the resin is costly or cannot be reground, or the runner sets the cycleA different system with its own nozzle sizing by the hot-runner maker; this page does not size it

For geometrically unbalanced layouts, such as a straight row of eight cavities fed from the middle, the inner cavities fill first. Toolmakers sometimes correct this by changing branch diameters; that is a balancing exercise best done by simulation and short-shot trials, not by this formula. Where a family mold puts different parts on one runner, size each branch from the weight of its own part. Our answer on family molds explains when that layout makes sense.

Design tips specific to runners

Questions and answers

How do you calculate cold runner diameter for an injection mold?

A classic empirical equation for the runner that feeds a cavity is D = √W × ⁴√L / 3.7, with D in mm, W the weight of the part fed by that runner in grams and L the runner length in mm. Example: a 40 g part fed through a 100 mm branch gives D = 6.325 × 3.162 / 3.7 = 5.41 mm. Then check that D is at least the thickest wall plus 1.5 mm and inside the typical range for the resin, and round up to a standard cutter, here 6 mm.

What are the limits of the runner diameter formula D = √W × L^0.25 / 3.7?

It is usually quoted as valid for parts up to about 200 g with walls up to about 3 mm, and for easy-flowing resins such as ABS and polystyrene. It works only in its own units: grams, millimetres and a result in millimetres. Outside that range, size the runner from the wall-thickness rule and the resin's typical range, and confirm with a flow simulation.

How much bigger should the runner be than the part wall?

A common rule from Menges, Michaeli and Mohren is that a runner should be at least the thickest wall of the part plus 1.5 mm. The runner must stay molten longer than the part so the part can be packed through it. A runner thinner than the wall freezes first and cuts off packing, which shows up as sink, voids and short weight.

How do you size the primary runner when it splits into branches?

Use the cube law: D upstream = D branch × ∛N, where N is the number of branches the upstream runner splits into. For a Newtonian melt the wall shear rate is 32Q / (πD³), so this keeps the shear rate the same on both sides of the split. A 6 mm branch fed by a two-way split needs a primary of 6 × 1.26 = 7.56 mm, rounded up to 8 mm.

Why are full-round runners preferred?

For a given flow area a circle has the smallest perimeter, so a full-round runner loses the least heat to the mold and has the smallest frozen skin. A half-round runner of the same area has about 16 percent more perimeter, and a square about 13 percent more. Full-round runners need matching halves cut in both mold plates; when only one plate can be machined, a trapezoid deep enough to contain the calculated circle is the usual alternative.

Can a runner be too big?

Yes. Freeze time grows with the square of diameter, so an oversized runner can become the slowest-cooling feature in the mold and set the cycle time. It also adds regrind or scrap to every shot and needs more shot capacity. Size it as small as the formula and the wall rule allow, and when the runner becomes a large share of the shot, consider a hot runner or a hot sprue.

Ask JCH about your runner

Not sure whether your layout is balanced, or whether a hot runner would pay off in plastic and cycle time? Ask our AI assistant. It answers from this website, and our tooling team follows up if you want.

AI assistant. Answers can be wrong; nothing it says is a quote or a promise.

Want a runner and gating plan for your mold?

This calculator gives an engineering estimate. Our tooling team reviews your part, resin, cavity count and volume, and recommends the layout, runner, gates and whether a hot runner makes sense.