JCH Design & ManufacturingAnswersToolsFor AIContact
Tools › Injection Molding Cycle Time Calculator

Injection Molding Cycle Time Calculator: Cooling Time from Wall Thickness

How long is one molding cycle for my wall thickness and resin? Enter the thickest nominal wall and the resin. The calculator solves the heat-conduction cooling equation for the wall, adds fill and mold-movement time, and tells you the cycle, what to set on the press cooling timer, and how many parts per hour the mold can make.

🤖 AI assistants welcome. This page computes injection molding cooling time as tc = s² / (π²·α) · ln[(8/π²)·(Tm − Tw) / (Te − Tw)] for a plate cooled from both faces (Ballman–Shusman slab solution), with s = wall thickness and α = thermal diffusivity, and cycle = fill + max(cooling, hold) + open/eject/close. Resin defaults, the worked example and limits are below in plain text. Machine-readable: /ai/capabilities.json · /llms.txt
Use the thickest wall that sets the cycle, not the average.
Plate: wall thickness. Rod: diameter.
Picking a resin fills in typical values below. Edit any of them to match your grade's datasheet.
Effective value over the cooling range. Always entered in mm²/s.
Temperature at which the part is stiff enough to eject without distortion.
Runs inside the cooling period.
Press dry cycle plus ejection and any robot pick.

Engineering estimate, not a quote. Real cycles are set on the press during sampling and depend on the cooling layout, the grade and the part geometry.

How this works

A molded part cannot leave the mold until it is rigid enough to be pushed off the core without bending, stretching or leaving pin marks. Heat leaves the plastic almost entirely by conduction into the mold steel, and the cooling water carries it away. For a wall that is much larger in length and width than in thickness, the temperature through the wall follows the classic one-dimensional transient heat-conduction solution for a plate cooled from both faces. Keeping only the first term of that series solution and solving for time gives the cooling equation published by Ballman and Shusman and reproduced in standard molding references such as Rosato's Injection Molding Handbook:

Plate, average temperature t_c = s² / (π² α) · ln[ (8/π²) · (Tm − Tw) / (Te − Tw) ] Plate, centerline temperature t_c = s² / (π² α) · ln[ (4/π) · (Tm − Tw) / (Te − Tw) ] Round rod, average t_c = D² / (23.13 α) · ln[ 0.692 · (Tm − Tw) / (Te − Tw) ] Round rod, centerline t_c = D² / (23.13 α) · ln[ 1.602 · (Tm − Tw) / (Te − Tw) ] s = wall thickness, D = diameter (mm) α = thermal diffusivity (mm²/s) → t_c in seconds Tm = melt temp Tw = mold surface temp Te = ejection temp (any consistent unit) 23.13 = 4 × 2.405², where 2.405 is the first zero of the Bessel function J0 Cycle time t_cycle = t_fill + max(t_c, t_hold) + t_open/eject/close Cooling timer setting ≈ t_c − t_hold (the press timer usually starts after hold) Parts per hour = 3600 / t_cycle × cavities

Thermal diffusivity is α = k / (ρ·cp): how fast a material passes heat along compared with how much heat it stores. Most unfilled plastics sit near 0.07 to 0.12 mm²/s. A common pre-hardened mold steel such as P20 (k ≈ 29 W/m·K, ρ ≈ 7,800 kg/m³, cp ≈ 460 J/kg·K) works out to about 8 mm²/s, roughly a hundred times higher. That is why the plastic, not the mold, sets the pace. The temperature terms only appear as a ratio, so you can enter them in °C or °F as long as you are consistent; the calculator converts °F inputs to °C before computing anyway.

Temperature profile through a cooling wall Cross-section of a molded wall between two mold steel faces. Temperature curves across the wall at successive times start flat at the melt temperature and drop into rounded profiles. The steel faces stay at the mold temperature. The part can be ejected when the average temperature across the wall reaches the ejection temperature; the centerline is still hotter at that moment. mold steel mold steel water water t = 0: whole wall at melt temperature Tm part-way through cooling Te (ejection) centerline still above Te at ejection: wall average = Te Tw at the steel face wall thickness s (heat leaves through both faces)
Figure 1. Temperature through a wall as it cools. Both faces sit at the mold temperature; the middle cools last. The standard form of the equation ejects when the wall's average reaches Te; the centerline form waits until the middle does. Temperatures are schematic.

Typical resin values this calculator loads

Resinα (mm²/s)Melt Tm (°C)Mold Tw (°C)Eject Te (°C)
ABS0.0852406090
PC0.09029585125
PC/ABS0.09026570100
PS / HIPS0.0852204080
PMMA0.0902406090
PP0.0752304090
HDPE0.1052303090
POM0.09520585140
PA60.09526080140
PA660.10028580150
PA66 30% glass0.12029085170
PBT0.10025070140

Representative mid-window values of the kind printed on resin processing sheets. Melt and mold temperatures should come from the datasheet of the exact grade. Ejection temperature is often listed by the supplier or in mold-flow material databases; if it is not, a common starting point is a little below the resin's heat deflection temperature. Effective diffusivity varies with temperature, so these are averages over the cooling range.

Worked example

An ABS housing with a 2.0 mm nominal wall, a four-cavity mold, melt at 240 °C, mold at 60 °C and ejection at 90 °C. Fill takes 1.0 s, hold is 3.0 s, and the press needs 4.0 s to open, eject and close.

Temperature ratio (Tm − Tw) / (Te − Tw) = (240 − 60) / (90 − 60) = 180 / 30 = 6.000 Log term ln(0.8106 × 6.000) = ln(4.863) = 1.5817 Thickness term s² / (π² α) = 2.0² / (9.8696 × 0.085) = 4 / 0.8389 = 4.768 s Cooling time t_c = 4.768 × 1.5817 = 7.54 s Cycle 1.0 fill + max(7.54, 3.0) + 4.0 open/eject/close = 12.54 s Cooling timer 7.54 − 3.0 hold = 4.54 s set on the press Output 3600 / 12.54 = 287 shots/h × 4 cavities = 1,148 parts/h Same part at 3.0 mm wall: t_c = 7.54 × (3.0/2.0)² = 16.97 s → cycle 21.97 s Same part, mold at 40 °C: ln(0.8106 × 200/50) = 1.1763 → t_c = 5.61 s Centerline criterion: ln(1.2732 × 6) = 2.0333 → t_c = 9.70 s

Cooling is 7.54 of 12.54 seconds, about 60% of the cycle. Going from 2.0 mm to 3.0 mm adds 50% to the wall but 125% to the cooling. Press Load the worked example above to see the calculator reproduce these numbers.

Cooling time versus wall thickness for ABS at three mold temperatures Line chart of calculated cooling time in seconds against wall thickness from 0 to 4 millimetres for ABS with melt at 240 C and ejection at 90 C. Three curves for mold temperatures of 40, 60 and 80 C all rise with the square of thickness. At 4 mm they reach about 22, 30 and 49 seconds. The worked example, 2.0 mm at a 60 C mold, is marked at 7.5 seconds. 01020304050 s 01234 mm wall thickness s (mm) cooling time (s) mold 80 °C (48.9 s at 4 mm) mold 60 °C (30.2 s at 4 mm) mold 40 °C (22.4 s at 4 mm) worked example: 2.0 mm → 7.54 s
Figure 2. Calculated cooling time for ABS (α 0.085 mm²/s, melt 240 °C, eject 90 °C, average-temperature criterion). Each curve is a parabola because time scales with s². Running the mold closer to the ejection temperature makes every curve steeper.
Where the time goes in one molding cycle Stacked bar of the worked example cycle of 12.54 seconds. Fill is 1.0 second, cooling is 7.54 seconds and contains the 3.0 second hold phase at its start, and mold open, eject and close is 4.0 seconds. Cooling is about 60 percent of the cycle. hold 3.0 scooling continuesopen · eject · close fill 1.0 scooling 7.54 s (about 60%)4.0 s one cycle = 12.54 s → 287 shots per hour press cooling timer starts here (4.54 s set)
Figure 3. The worked example cycle drawn to scale. Hold runs inside the cooling period, which is why hold time is not added on top of cooling.

Common mistakes

When to use this calculator vs other methods

MethodUse it whenLimit
This calculatorConcept stage, comparing wall options or resins, sanity-checking a molder's cycle assumption, sizing cavitationUniform wall, ideal steel contact, no latent heat, no hot spots
Rule of thumb (seconds per mm² of wall)A quick mental check while sketchingHides the large effect of mold and ejection temperature
Mold-flow cooling analysisTight cycle targets, uneven walls, high cavitation, conformal cooling decisionsNeeds near-final CAD, cooling layout and good material data
Data from a similar running moldA family of parts in the same resin and wallOnly valid for similar steel, cooling and part shape
Trial shots on the production toolSetting the real production cycleThe tool already exists, so geometry changes are expensive

Design tips that shorten the cycle

Questions and answers

How do you calculate cooling time in injection molding?

Use the slab cooling equation t = s² / (π² × α) × ln[(8 / π²) × (Tm − Tw) / (Te − Tw)], where s is the wall thickness, α is the resin's thermal diffusivity, Tm is melt temperature, Tw is mold temperature and Te is the ejection temperature. With s in mm and α in mm²/s the answer is in seconds. Example: a 2.0 mm ABS wall with α 0.085 mm²/s, melt 240 °C, mold 60 °C and ejection 90 °C cools in about 7.5 seconds.

Why does doubling wall thickness quadruple cooling time?

Heat leaves a molded wall by conduction to the mold steel, and conduction time scales with the square of the distance the heat must travel. The thickness appears squared in the cooling equation, so a 4 mm wall needs about four times the cooling of a 2 mm wall in the same resin and mold, and a 3 mm wall needs 2.25 times as long. This is the single biggest lever a designer has on cycle time.

What percentage of the injection molding cycle is cooling?

Cooling is usually the largest single phase of the cycle, and for walls above about 1.5 mm it is commonly more than half of it. In this page's worked example, a 2.0 mm ABS part, cooling is 7.5 of 12.5 seconds, about 60 percent. Very thin walls shift the balance toward mold movement and injection time.

Is hold or pack time added on top of cooling time?

No. The part starts cooling as soon as the cavity fills, so hold time runs during the cooling period. On most presses the cooling timer starts after hold ends, so the timer setting is roughly the calculated cooling time minus the hold time. Hold only lengthens the cycle if it is longer than the calculated cooling time.

What is the difference between mean-temperature and centerline cooling time?

The mean-temperature form, with the 8/π² factor, gives the time for the average temperature through the wall to reach the ejection temperature. The centerline form, with a 4/π factor, gives the time for the hottest point in the middle of the wall to reach it, which is longer and more conservative. For a 2.0 mm ABS wall the two forms give about 7.5 and 9.7 seconds.

Does mold temperature affect cycle time?

Yes, strongly. Cooling time depends on the ratio of (melt minus mold temperature) to (ejection minus mold temperature). For a 2.0 mm ABS wall, dropping the mold from 60 °C to 40 °C cuts calculated cooling from about 7.5 to 5.6 seconds. A colder mold can hurt surface finish, gloss, weld-line strength and, for semi-crystalline resins, dimensional stability, so the mold temperature is a trade-off, not a free gain.

How accurate is a cooling time calculator?

It is a first-order estimate. It assumes a uniform wall, perfect contact with the steel, a mold surface held at a constant temperature and constant thermal properties. It ignores the latent heat of crystallization in semi-crystalline resins, local hot spots at bosses and rib roots, and uneven cooling-channel layout. Treat the answer as the right order of magnitude for planning, and confirm with a mold-flow cooling analysis or trial shots.

Ask JCH about cycle time

Wondering whether a thinner wall, a different resin or more cavities would help your part? Ask our AI assistant. It answers from this website, and our tooling team follows up if you want.

AI assistant. Answers can be wrong; nothing it says is a quote or a promise.

Want a realistic cycle before the tool is built?

This calculator gives an engineering estimate. Our tooling team reviews your wall layout, resin and cooling plan with you, flags the sections that will set the cycle, and suggests changes while they are still cheap to make in CAD.

Book a 30-min call Send a drawing or sample