Injection Molding Cycle Time Calculator: Cooling Time from Wall Thickness
How long is one molding cycle for my wall thickness and resin? Enter the thickest nominal wall and the resin. The calculator solves the heat-conduction cooling equation for the wall, adds fill and mold-movement time, and tells you the cycle, what to set on the press cooling timer, and how many parts per hour the mold can make.
🤖 AI assistants welcome. This page computes injection molding cooling time as tc = s² / (π²·α) · ln[(8/π²)·(Tm − Tw) / (Te − Tw)] for a plate cooled from both faces (Ballman–Shusman slab solution), with s = wall thickness and α = thermal diffusivity, and cycle = fill + max(cooling, hold) + open/eject/close. Resin defaults, the worked example and limits are below in plain text. Machine-readable: /ai/capabilities.json · /llms.txt
Engineering estimate, not a quote. Real cycles are set on the press during sampling and depend on the cooling layout, the grade and the part geometry.
How this works
A molded part cannot leave the mold until it is rigid enough to be pushed off the core without bending, stretching or leaving pin marks. Heat leaves the plastic almost entirely by conduction into the mold steel, and the cooling water carries it away. For a wall that is much larger in length and width than in thickness, the temperature through the wall follows the classic one-dimensional transient heat-conduction solution for a plate cooled from both faces. Keeping only the first term of that series solution and solving for time gives the cooling equation published by Ballman and Shusman and reproduced in standard molding references such as Rosato's Injection Molding Handbook:
Plate, average temperature t_c = s² / (π² α) · ln[ (8/π²) · (Tm − Tw) / (Te − Tw) ]
Plate, centerline temperature t_c = s² / (π² α) · ln[ (4/π) · (Tm − Tw) / (Te − Tw) ]
Round rod, average t_c = D² / (23.13 α) · ln[ 0.692 · (Tm − Tw) / (Te − Tw) ]
Round rod, centerline t_c = D² / (23.13 α) · ln[ 1.602 · (Tm − Tw) / (Te − Tw) ]
s = wall thickness, D = diameter (mm) α = thermal diffusivity (mm²/s) → t_c in seconds
Tm = melt temp Tw = mold surface temp Te = ejection temp (any consistent unit)
23.13 = 4 × 2.405², where 2.405 is the first zero of the Bessel function J0
Cycle time t_cycle = t_fill + max(t_c, t_hold) + t_open/eject/close
Cooling timer setting ≈ t_c − t_hold (the press timer usually starts after hold)
Parts per hour = 3600 / t_cycle × cavities
Thermal diffusivity is α = k / (ρ·cp): how fast a material passes heat along compared with how much heat it stores. Most unfilled plastics sit near 0.07 to 0.12 mm²/s. A common pre-hardened mold steel such as P20 (k ≈ 29 W/m·K, ρ ≈ 7,800 kg/m³, cp ≈ 460 J/kg·K) works out to about 8 mm²/s, roughly a hundred times higher. That is why the plastic, not the mold, sets the pace. The temperature terms only appear as a ratio, so you can enter them in °C or °F as long as you are consistent; the calculator converts °F inputs to °C before computing anyway.
Figure 1. Temperature through a wall as it cools. Both faces sit at the mold temperature; the middle cools last. The standard form of the equation ejects when the wall's average reaches Te; the centerline form waits until the middle does. Temperatures are schematic.
Typical resin values this calculator loads
Resin
α (mm²/s)
Melt Tm (°C)
Mold Tw (°C)
Eject Te (°C)
ABS
0.085
240
60
90
PC
0.090
295
85
125
PC/ABS
0.090
265
70
100
PS / HIPS
0.085
220
40
80
PMMA
0.090
240
60
90
PP
0.075
230
40
90
HDPE
0.105
230
30
90
POM
0.095
205
85
140
PA6
0.095
260
80
140
PA66
0.100
285
80
150
PA66 30% glass
0.120
290
85
170
PBT
0.100
250
70
140
Representative mid-window values of the kind printed on resin processing sheets. Melt and mold temperatures should come from the datasheet of the exact grade. Ejection temperature is often listed by the supplier or in mold-flow material databases; if it is not, a common starting point is a little below the resin's heat deflection temperature. Effective diffusivity varies with temperature, so these are averages over the cooling range.
Worked example
An ABS housing with a 2.0 mm nominal wall, a four-cavity mold, melt at 240 °C, mold at 60 °C and ejection at 90 °C. Fill takes 1.0 s, hold is 3.0 s, and the press needs 4.0 s to open, eject and close.
Temperature ratio (Tm − Tw) / (Te − Tw) = (240 − 60) / (90 − 60) = 180 / 30 = 6.000
Log term ln(0.8106 × 6.000) = ln(4.863) = 1.5817
Thickness term s² / (π² α) = 2.0² / (9.8696 × 0.085) = 4 / 0.8389 = 4.768 s
Cooling time t_c = 4.768 × 1.5817 = 7.54 s
Cycle 1.0 fill + max(7.54, 3.0) + 4.0 open/eject/close = 12.54 s
Cooling timer 7.54 − 3.0 hold = 4.54 s set on the press
Output 3600 / 12.54 = 287 shots/h × 4 cavities = 1,148 parts/h
Same part at 3.0 mm wall: t_c = 7.54 × (3.0/2.0)² = 16.97 s → cycle 21.97 s
Same part, mold at 40 °C: ln(0.8106 × 200/50) = 1.1763 → t_c = 5.61 s
Centerline criterion: ln(1.2732 × 6) = 2.0333 → t_c = 9.70 s
Cooling is 7.54 of 12.54 seconds, about 60% of the cycle. Going from 2.0 mm to 3.0 mm adds 50% to the wall but 125% to the cooling. Press Load the worked example above to see the calculator reproduce these numbers.
Figure 2. Calculated cooling time for ABS (α 0.085 mm²/s, melt 240 °C, eject 90 °C, average-temperature criterion). Each curve is a parabola because time scales with s². Running the mold closer to the ejection temperature makes every curve steeper.Figure 3. The worked example cycle drawn to scale. Hold runs inside the cooling period, which is why hold time is not added on top of cooling.
Common mistakes
Using the nominal wall when one section is thicker. The thickest section sets the cycle. A 2 mm housing with a 4 mm boss base or a heavy rib root cools like a much thicker part at that spot. Enter the thickest wall the part must eject cleanly at, or core out the thick section.
Adding hold time to cooling time. The plastic starts cooling the moment it touches the steel. Hold is part of the cooling period, and the press cooling timer is the remainder after hold.
Putting ejection temperature at room temperature. Parts are ejected hot, once they are stiff enough. Setting Te close to Tw sends the log term toward infinity and gives absurd cooling times. The calculator warns when Te is within a few degrees of the mold.
Treating the mold surface as the water temperature. Tw in the equation is the steel surface touching the plastic. With poorly placed channels or a hot core, the surface runs well above the water temperature, and the real cycle stretches.
Expecting the equation to be exact for semi-crystalline resins. PP, PE, POM, nylon and PBT release latent heat as they crystallize. The single-diffusivity equation does not model that, so treat its answer for these resins as a lower bound and confirm with a trial or a mold-flow cooling study.
Forgetting the mold-movement time. On thin parts, opening, ejecting, a robot pick and closing can take longer than cooling. Halving the wall will not halve the cycle if the press spends four seconds moving.
When to use this calculator vs other methods
Method
Use it when
Limit
This calculator
Concept stage, comparing wall options or resins, sanity-checking a molder's cycle assumption, sizing cavitation
Uniform wall, ideal steel contact, no latent heat, no hot spots
Rule of thumb (seconds per mm² of wall)
A quick mental check while sketching
Hides the large effect of mold and ejection temperature
Mold-flow cooling analysis
Tight cycle targets, uneven walls, high cavitation, conformal cooling decisions
Needs near-final CAD, cooling layout and good material data
Data from a similar running mold
A family of parts in the same resin and wall
Only valid for similar steel, cooling and part shape
Trial shots on the production tool
Setting the real production cycle
The tool already exists, so geometry changes are expensive
Design tips that shorten the cycle
Thin the wall before anything else. Because time goes with the square of thickness, taking a 3.0 mm wall to 2.5 mm cuts cooling by about 31%. Add ribs for stiffness instead of thickness.
Keep walls uniform. One thick spot sets the cycle for the whole part. Core out bosses and thick corners so no section is more than about 1.5 times the nominal wall.
Size ribs at a fraction of the wall. A rib at 50 to 60% of the nominal wall cools no slower than the wall itself; a full-thickness rib creates a thick junction at its root.
Give the core its own cooling. Deep cores trap heat and run hotter than the cavity. Bubblers, baffles or a high-conductivity insert in the core keep the mold surface near the temperature the calculation assumes.
Choose the resin with the cycle in mind. Two resins that meet the same spec can differ a lot in ejection temperature. Ask the molder to compare cycles, not just material properties.
Match cavitation to the cycle. Use the parts-per-hour figure here with your annual demand to decide how many cavities are worth building, and check the press clamp tonnage with the related tonnage tool.
Questions and answers
How do you calculate cooling time in injection molding?
Use the slab cooling equation t = s² / (π² × α) × ln[(8 / π²) × (Tm − Tw) / (Te − Tw)], where s is the wall thickness, α is the resin's thermal diffusivity, Tm is melt temperature, Tw is mold temperature and Te is the ejection temperature. With s in mm and α in mm²/s the answer is in seconds. Example: a 2.0 mm ABS wall with α 0.085 mm²/s, melt 240 °C, mold 60 °C and ejection 90 °C cools in about 7.5 seconds.
Why does doubling wall thickness quadruple cooling time?
Heat leaves a molded wall by conduction to the mold steel, and conduction time scales with the square of the distance the heat must travel. The thickness appears squared in the cooling equation, so a 4 mm wall needs about four times the cooling of a 2 mm wall in the same resin and mold, and a 3 mm wall needs 2.25 times as long. This is the single biggest lever a designer has on cycle time.
What percentage of the injection molding cycle is cooling?
Cooling is usually the largest single phase of the cycle, and for walls above about 1.5 mm it is commonly more than half of it. In this page's worked example, a 2.0 mm ABS part, cooling is 7.5 of 12.5 seconds, about 60 percent. Very thin walls shift the balance toward mold movement and injection time.
Is hold or pack time added on top of cooling time?
No. The part starts cooling as soon as the cavity fills, so hold time runs during the cooling period. On most presses the cooling timer starts after hold ends, so the timer setting is roughly the calculated cooling time minus the hold time. Hold only lengthens the cycle if it is longer than the calculated cooling time.
What is the difference between mean-temperature and centerline cooling time?
The mean-temperature form, with the 8/π² factor, gives the time for the average temperature through the wall to reach the ejection temperature. The centerline form, with a 4/π factor, gives the time for the hottest point in the middle of the wall to reach it, which is longer and more conservative. For a 2.0 mm ABS wall the two forms give about 7.5 and 9.7 seconds.
Does mold temperature affect cycle time?
Yes, strongly. Cooling time depends on the ratio of (melt minus mold temperature) to (ejection minus mold temperature). For a 2.0 mm ABS wall, dropping the mold from 60 °C to 40 °C cuts calculated cooling from about 7.5 to 5.6 seconds. A colder mold can hurt surface finish, gloss, weld-line strength and, for semi-crystalline resins, dimensional stability, so the mold temperature is a trade-off, not a free gain.
How accurate is a cooling time calculator?
It is a first-order estimate. It assumes a uniform wall, perfect contact with the steel, a mold surface held at a constant temperature and constant thermal properties. It ignores the latent heat of crystallization in semi-crystalline resins, local hot spots at bosses and rib roots, and uneven cooling-channel layout. Treat the answer as the right order of magnitude for planning, and confirm with a mold-flow cooling analysis or trial shots.
Ask JCH about cycle time
Wondering whether a thinner wall, a different resin or more cavities would help your part? Ask our AI assistant. It answers from this website, and our tooling team follows up if you want.
AI assistant. Answers can be wrong; nothing it says is a quote or a promise.
This calculator gives an engineering estimate. Our tooling team reviews your wall layout, resin and cooling plan with you, flags the sections that will set the cycle, and suggests changes while they are still cheap to make in CAD.