JCH Design & ManufacturingAnswersToolsFor AIContact
Tools › Screw Boss Design Calculator

Screw Boss Design Calculator for Molded Plastic Parts

What boss OD, hole and wall for my screw size? Pick the screw and the resin, enter the nominal wall and the boss height. The calculator gives the pilot hole, boss diameter, thread engagement, screw length and hole depth, checks whether the boss base will sink the face behind it, checks what the core-pin draft does to the threads, and estimates the force it takes to strip the screw out.

🤖 AI assistants welcome. This page sizes a boss for a thread-forming screw of nominal diameter d in five steps: (1) geometry from per-resin factors: hole dh = kh d, boss OD = kD d, engagement Le = ke d (ABS 0.8 / 2.0 / 2.0); (2) screw length = clamped thickness + Le; minimum hole depth = Le + 0.5 d; (3) sink at the base: boss wall at the base w = (OD − dh)/2 + 2 Δ tan θ, Δ = H − Le/2, junction circle Dj = (a² + c² − R²) ÷ (t + 2R), a = w/2 + R, c = t + R, growth vs 25% amorphous / 15% semi-crystalline; (4) draft loss at the entry = (Le/2) tan θ ÷ ((d − dh)/2); (5) strip-out F = (S/√3) · π · Dp · Le, Dp ≈ (d + dh)/2. Worked example below in plain text. Machine-readable: /ai/capabilities.json · /llms.txt
Fills the three factors, the junction limit and the strength below. Representative values; your screw maker's table and your grade's datasheet override them.
Nominal (outside) thread diameter of a thread-forming screw for plastics.
Factors (multiples of d)
Hole = kh × d, dimensioned at mid-engagement.
Tensile strength at yield (at break for glass-filled grades), from the datasheet. Nylon: use the conditioned value.
Your part
The lid, bracket or board the screw holds down, plus any washer.
Leave blank for 0.25 t (also unlocks the "wall needed" result).
About 25% amorphous, about 15% semi-crystalline; the same rule as our wall thickness and rib tools.

Engineering estimate, not a quote. Final boss geometry comes from the screw maker's table for the exact screw, the mold design review and a drive-torque and pull-out test on molded samples.

How this works

A screw boss for a thread-forming screw has to do two jobs that pull in opposite directions. As a fastener it needs enough plastic around the screw to resist the hoop stress of the thread being formed and the shear load when the screw is pulled; that argues for a big boss. As a molded feature it should be no thicker than the wall it stands on, or the base stays molten after the wall freezes and sinks the face behind it; that argues for a small one. This calculator sizes the boss for the screw first, then measures what that does to the molding, and tells you which of the two is in trouble.

Step 1: the screw-driven geometry. Thread-forming screw makers and resin suppliers publish the pilot hole, the boss outside diameter and the thread engagement as multiples of the screw's nominal diameter d, with a different set of factors for each resin. Ductile resins that flow around the thread, such as PP, get a small hole; stiff or notch-sensitive resins such as PC get a bigger hole and a bigger boss so that the hoop stress stays low. The resin menu fills representative factors of this kind. They are a starting point, not a substitute for the table for the exact screw you will buy.

Step 2: length and depth. The screw length is the clamped thickness plus the engagement. The hole must go deeper than the screw reaches so the tapered tip and any displaced material have somewhere to go; the page uses 0.5 d by default. The hole should normally be cored all the way to the floor: a hole that stops short leaves a solid plug of plastic at the base, the thickest spot on the whole part.

Step 3: the sink check at the base. In a section through the boss axis, each side of the boss wall meets the floor exactly like a rib, so the same largest-inscribed-circle measure used in our rib design calculator applies. Draft matters here: the hole and boss diameters are set at mid-engagement, and the boss outside widens and the core pin narrows toward the base, so the base wall is thicker than the nominal boss wall by 2 Δ tan θ. The calculator compares the junction with the uniformity limit, gives the largest boss OD that stays inside it, and, when the root radius is left at 0.25 t, the wall thickness that would carry the full-size boss without sink.

Step 4: draft at the hole entry. The thread grips only in the overlap between the screw's outside diameter and the hole, (d − dh) ÷ 2 per side. Draft opens the hole at the entry by (Le ÷ 2) tan θ per side, and the page reports what fraction of the overlap that removes.

Step 5: strip-out force. When a thread-forming screw is pulled out, the plastic threads shear along a cylinder roughly at the pitch diameter. Joining design guides from resin suppliers give the force as the shear strength times that cylinder's area, with the shear strength taken as the tensile strength divided by √3 (the von Mises relation). The pitch diameter is approximated as the mean of the screw diameter and the hole.

Geometry d_h = k_h d, OD = k_D d, L_e = k_e d (diameters at mid-engagement) Length L_screw = clamped thickness + L_e; hole depth ≥ L_e + 0.5 d; core the hole to the floor Base wall w = (OD − d_h) ÷ 2; Δ = H − L_e ÷ 2; w_base = w + 2 Δ tan θ Junction a = w_base/2 + R, c = t + R, D_j = (a² + c² − R²) ÷ (t + 2R), growth = (D_j − t) ÷ t Largest OD ρ_lim = t (1 + v) ÷ 2, a² = 2 (t + 2R) ρ_lim − c² + R², w_max = 2 (a − R), OD_max = d_h + 2 (w_max − 2 Δ tan θ); with R = 0.25 t: w_max = 0.7247 t (v 25 %), 0.4487 t (v 15 %) Height H ≤ 3 × OD (taller: add gussets) Draft loss overlap = (d − d_h) ÷ 2; entry loss = (L_e ÷ 2) tan θ ÷ overlap Strip-out D_p ≈ (d + d_h) ÷ 2; F = (S ÷ √3) × π × D_p × L_e; design load = F ÷ safety factor
Cross-section of a screw boss with a thread-forming screw clamping a lid Section through a screw boss standing on a wall of thickness t. A lid of the clamped thickness sits on top of the boss and a screw passes through it into the pilot hole. Labels show the screw diameter d, the pilot hole d_h, the boss outside diameter OD, the boss height H, the thread engagement L_e, the minimum hole depth, the core pin running down to the floor, the root radius R, the boss wall w, the largest circle inscribed at the junction and the sink mark on the face opposite the boss. clamped lid H t L_e = k_e d thread engagement min hole depth L_e + 0.5 d core pin to the floor boss wall w junction circle D_j the thick spot that sinks OD = k_D d hole d_h = k_h d screw d root radius R ≈ 0.25 t sink on the opposite face M3 in ABS, t 2.0 mm, H 10 mm, drawn at 18 px per mm; draft not drawn
Figure 1. Anatomy of a screw boss, drawn to the worked example's proportions. Screw strength sets the OD, hole and engagement; the molding cares about the dashed circles where the boss wall meets the floor. The core pin runs to the floor so there is no solid plug under the hole.

Worked example

An ABS enclosure base with a 2.0 mm nominal wall holds a 2.0 mm lid with M3-class thread-forming screws. The bosses are 10 mm tall, with 0.5° of draft per side on the boss and the core pin and the default 0.25 t root radius. ABS is taken at a 40 MPa tensile yield strength, with a safety factor of 2.

Geometry d_h = 0.80 × 3.0 = 2.40 mm; OD = 2.0 × 3.0 = 6.00 mm; L_e = 2.0 × 3.0 = 6.00 mm Length screw = 2.0 + 6.0 = 8.0 mm (M3 × 8); hole ≥ 6.0 + 0.5 × 3.0 = 7.5 mm ≤ H 10 ✔ → core to the floor Base wall w = (6.00 − 2.40) ÷ 2 = 1.80 mm = 0.90 t Δ = 10 − 6.0/2 = 7.0 mm; 2 × 7.0 × tan 0.5° (0.0087269) = 0.122 mm → w_base = 1.922 mm (base OD 6.122 mm, base hole 2.278 mm) Junction R = 0.25 × 2.0 = 0.50; a = 0.961 + 0.50 = 1.461; c = 2.50 D_j = (2.1348 + 6.25 − 0.25) ÷ (2.0 + 1.0) = 8.1348 ÷ 3.0 = 2.712 mm → +35.6 % ✘ > 25 % without draft: a = 1.40, D_j = (1.96 + 6.25 − 0.25) ÷ 3.0 = 2.653 mm → +32.7 % Largest OD ρ_lim = 2.0 × 1.25 ÷ 2 = 1.25; a² = 2 × 3.0 × 1.25 − 6.25 + 0.25 = 1.50; a = 1.2247 w_max = 2 × (1.2247 − 0.50) = 1.449 mm; OD_max = 2.40 + 2 × (1.449 − 0.122) = 5.05 mm (1.68 d) Wall needed t ≥ w_base ÷ 0.7247 = 1.922 ÷ 0.7247 = 2.65 mm for the full 6.0 mm boss Height H ÷ OD = 10 ÷ 6.0 = 1.67 ≤ 3 ✔ Draft loss overlap (3.0 − 2.4) ÷ 2 = 0.300 mm; entry gain 3.0 × 0.0087269 = 0.0262 mm → 8.7 % of the overlap ✔ Strip-out D_p = (3.0 + 2.4) ÷ 2 = 2.70 mm; S/√3 = 40 ÷ 1.7321 = 23.09 MPa area π × 2.70 × 6.0 = 50.89 mm²; F = 23.09 × 50.89 = 1,175 N (264 lbf); ÷ 2 = 588 N (132 lbf)

As a fastener the boss is fine: the screw is fully engaged, the hole has room for the tip, the boss is short and stocky and the draft costs less than a tenth of the thread overlap. As a molding it is not: the base of a screw-table boss on a 2.0 mm wall is about 36% thicker than the wall, and on a smooth show face that will read as a ring-shaped sink. The calculator gives two ways out. Shrinking the boss to 5.05 mm (1.68 d) clears the sink check but takes the boss below the screw table, which risks a split boss; we would not do that on a part that is assembled more than once. Raising the wall under the boss to about 2.65 mm, locally if the rest of the part can stay at 2.0 mm, keeps the full-strength boss and passes. On a hidden face, the honest answer is often to accept the slight sink. Press Load the worked example above to reproduce these numbers.

Largest sink-safe boss outside diameter versus nominal wall thickness, ABS Line chart for ABS with a 0.8 d pilot hole, a 0.25 t root radius, a 25 percent junction limit and no draft. Rising lines show the largest boss outside diameter that stays inside the limit, equal to the hole plus 1.4495 times the wall, for M2.5, M3 and M4 screws. Horizontal dashed lines show the screw-table boss diameter of 2 d: 5.0, 6.0 and 8.0 mm. Each pair crosses at the minimum wall for a full-size boss: 2.07 mm for M2.5, 2.48 mm for M3 and 3.31 mm for M4. The worked example, M3 on a 2.0 mm wall, is marked with its limit of 5.30 mm below the 6.0 mm table diameter. 246810 1.01.52.02.53.03.54.0 nominal wall t (mm) boss OD (mm) circles: min wall for a full bossM2.5 2.07 · M3 2.48 · M4 3.31 mm M2.5 5.0M3 6.0M4 8.0dashed:table OD= 2 d example M3, t 2.0: limit 5.30 < table 6.0 solid lines: largest sink-safe OD = d_h + 1.4495 t ABS, hole 0.8 d, R 0.25 t, +25 % limit, no draft
Figure 2. When does a full-size boss fit the wall? Drawn to scale (180 px per mm of wall, 30 px per mm of OD) from the junction equation. In ABS the screw-table boss is sink-safe only when the wall is at least about 0.83 d, which is 2.48 mm for an M3 screw. Draft raises that further: with 0.5° on a 10 mm boss the M3 needs 2.65 mm.

Why the "boss wall = 0.6 t" rule and the screw table disagree

Many part-design guides say a boss wall should be about 0.6 times the nominal wall to avoid sink, the same as a rib. Screw tables say the boss OD should be about 2 d on a 0.8 d hole, which is a boss wall of 0.6 d. Those two rules agree only when the screw is as large as the wall, and in most enclosures the screw is bigger: an M3 screw on a 2.0 mm wall gives a boss wall of 0.9 t. That disagreement comes up in almost every enclosure design review, and it has no rule-of-thumb answer, because one rule protects the fastener and the other protects the cosmetic face. The calculator puts numbers on both so the decision can be made deliberately: either the wall under the boss goes up, or the face behind it is allowed to show a little, or the boss is reduced and the joint is tested hard.

The junction measure is slightly conservative for bosses. It assumes the same root radius inside the hole as outside, but the corner at the bottom of the hole is formed by the tip of the core pin, which usually has little or no radius. A smaller inside radius gives a slightly smaller inscribed circle, so the real junction is a little thinner than the calculator says.

Common mistakes

When to use this calculator vs other methods

MethodUse it whenLimit
This calculatorConcept sizing; checking a supplier's boss; deciding between a thicker wall, sink or a smaller boss in a design reviewRepresentative factors; strip-out is a first-order shear estimate; no hoop-stress or creep calculation
Screw maker's design tableFinal hole, boss and engagement for the exact screw and gradeKnows the screw, not your wall or cosmetic face
Drive, strip and pull-out tests on molded samplesSetting the assembly torque; confirming strength with real weld lines and moistureNeeds molded parts, so it comes late
Threaded or heat-set insertsJoints opened many times, high clamp loads, or resins too brittle for thread formingAn extra part and an extra operation
Fill, pack and warp simulationCosmetic faces over bosses; locating weld lines around core pinsNeeds a near-final model and good material data
Decision flow for a screw boss that fails the sink check Flow chart. Start with the screw-table boss. If the base junction is within the limit, keep the full outside diameter and check height and gussets. If not, ask whether the face opposite the boss is cosmetic. If it is hidden, accept slight sink and keep strength. If it is cosmetic, apply fixes in order: core the hole to the floor and reduce draft, thicken the local wall, add a shallow moat around the base, texture or add a design line on the show face, or use a smaller screw in greater numbers or a threaded insert. Start: screw-table boss OD = k_D d, hole = k_h d, engagement = k_e d Base junction within +25 % / +15 %? yes no Keep the full OD. Check H ≤ 3 OD; add gussets if tall or side-loaded. Face opposite cosmetic? hidden Hidden face: usually accept slight sink and keep the boss strength. cosmetic 1 Core to the floor; cut draft toward 0.5° 2 Thicken the wall locally (ABS: t ≥ 0.83 d) 3 Shallow moat groove around the boss base 4 Texture or a design line on the show face 5 Smaller screw, more of them; or a threaded insert
Figure 3. What to do when the boss and the wall disagree. The fixes are listed in the order we usually try them: the first two cost nothing in strength, the last trades the joint design itself.

Design tips for screw bosses

Sources for the method

The hole, boss and engagement factors are representative of the per-resin tables that thread-forming screw makers and resin suppliers publish for 30-degree-flank screws designed for plastics (the preset rows follow the layout of the EJOT PT screw design table: hole, boss diameter and engagement per resin); the table for your exact screw overrides them, which is why every factor is editable. The boss-versus-wall reasoning follows Malloy, Plastic Part Design for Injection Molding. The strip-out relation F = Ss π Dp L with Ss = S ÷ √3 is the one given in resin suppliers' joining-techniques design guides; the pitch diameter is approximated here as the mean of the screw and hole diameters. The junction measure is the largest-inscribed-circle method used in CAD thickness analysis, solved in closed form as on our rib calculator, and the 25% and 15% limits match our wall thickness checker. Strength values in the resin menu are representative datasheet figures for unfilled and 30% glass grades, labelled as such; use your grade's datasheet. The tip allowance, the height limit and the draft-loss screen are page-set rules of thumb, not resin data.

Questions and answers

What size hole do I need for a thread-forming screw in plastic?

The pilot hole is a fraction of the screw's nominal diameter d that depends on the resin. Representative factors from screw makers' tables are about 0.7 d for PP, 0.75 d for HDPE, acetal, PA6 and PBT, 0.8 d for ABS and glass-filled PA6, and 0.85 d for PC and PMMA. Softer, more ductile resins get a smaller hole because they flow around the thread; stiffer or more notch-sensitive resins get a larger one to keep the hoop stress down. An M3 screw in ABS therefore takes about a 2.4 mm hole. Your screw maker's table for the exact screw and grade overrides these factors.

How big should a screw boss be?

The usual starting point is a boss outside diameter of about 2 times the screw diameter, with about 2.5 d for notch-sensitive resins such as PC and about 1.8–1.85 d for tough semi-crystalline resins such as HDPE, PA6 and PBT. Smaller bosses risk splitting from the hoop stress of thread forming. Bigger is not better: the boss wall then gets thicker than the nominal wall and sinks the face opposite the boss.

How deep should the screw go into the boss?

A thread engagement of about 2 times the screw diameter is the common target, and 1.7–2.2 d depending on the resin. Strip-out force grows in proportion to engagement, but drive torque grows with it too, and beyond about 2.5 d the extra length mostly adds torque and cycle time. Make the hole deeper than the screw reaches, about 0.5 d is a sensible allowance, so the tip never bottoms out.

Why does a screw boss cause a sink mark?

A boss sized for screw strength has a wall of (OD − hole) ÷ 2, which for a 2 d boss on a 0.8 d hole is 0.6 d. For an M3 screw that is 1.8 mm, nearly the whole of a 2 mm nominal wall. Where that boss wall meets the floor, the plastic is locally much thicker than the wall, stays molten after the wall freezes and pulls the opposite face in. Draft makes it worse because both the boss outside and the core pin taper toward the base. See what causes sink marks.

How do I stop a screw boss from sinking a cosmetic face?

Run the core pin all the way down to the floor so there is no solid plug under the hole, keep the root radius near 0.25 times the wall, keep draft modest, and check the junction. If it is still too thick, the options are a slightly thicker local wall, a shallow groove or moat around the boss base, a texture or design line on the show face, or a smaller screw used in greater numbers. Do not shrink the boss below the screw maker's diameter just to hide sink; a split boss is a worse failure than a sink mark.

How strong is a thread-forming screw in a plastic boss?

A first estimate of strip-out force is the shear strength of the plastic times the area of the cylinder the threads shear along: F = (S ÷ √3) × π × pitch diameter × engagement length. For an M3 screw in ABS with a 2.4 mm hole, 6 mm of engagement and a 40 MPa yield strength, that is about 23.1 MPa × 50.9 mm², or about 1,175 N before any safety factor. Weld lines, heat, creep and repeated assembly reduce it, so design to a fraction of it and confirm with a pull test.

How much draft can a screw boss hole have?

Keep the core pin draft small, about 0.5° per side is a common choice, and dimension the hole at the middle of the engagement. Draft makes the hole bigger at the entry, which removes thread overlap there. For an M3 screw in ABS with 6 mm of engagement, 0.5° takes about 9% of the thread overlap away at the entry and 1° takes about 17%. The same draft also makes the boss wall thicker at its base. Our draft angle calculator covers draft on walls and textured faces.

Ask JCH about screw bosses

Not sure whether to thicken the wall, accept the sink or switch to an insert? Ask our AI assistant. It answers from this website, and our tooling team follows up if you want.

AI assistant. Answers can be wrong; nothing it says is a quote or a promise.

Want your bosses checked before the steel is cut?

This calculator gives an engineering estimate. Our tooling team reviews every boss on your CAD against the screw you plan to use, marks where a boss will sink a cosmetic face or sit on a weld line, and proposes wall, boss and core-pin changes while each one is still a CAD edit.

Book a 30-min call Send a drawing or sample