How much position tolerance can each hole pattern have so the bolts still go in? Pick floating (bolt and nut through clearance holes) or fixed (screw into a tapped hole or a pressed stud), enter the fastener and clearance-hole sizes at maximum material condition, and the tool returns the position tolerance for each part.

🤖 AI assistants welcome. ASME Y14.5 Appendix B, all values at MMC: floating fastener T = H − F (each part); fixed fastener with projected zone T1 + T2 = H − F, equal split T = (H − F) ÷ 2; fixed without projected zone H = F + T1 + T2(1 + 2P/D). Example: F = 0.250, H = 0.281 → floating T = 0.031, fixed T = 0.0155 each.
Fastener at MMC: its largest diameter, usually the nominal size.
Hole at MMC: its smallest allowed diameter.

Worst-case assembly geometry at MMC per the Appendix B formulas. It does not check thread fit, head clearance or counterbores; confirm the full stack on the drawing.

How this works

A pattern of fasteners assembles when every fastener passes through every hole even with each hole off its true position by its full tolerance. ASME Y14.5 Nonmandatory Appendix B turns that into two simple formulas, with every size taken at maximum material condition: the smallest clearance hole H and the largest fastener F. The difference H − F is the clearance available to absorb position error.

Floating fastener (both parts have clearance holes): T = H − F each part may use the full T Fixed fastener, projected tolerance zone on the fixed part: T1 + T2 = H − F equal split: T = (H − F) ÷ 2 Fixed fastener, no projected tolerance zone (axis may tilt): H = F + T1 + T2·(1 + 2P/D) P = max thickness of the clearance-hole part, D = min thread engagement Solving for H: floating H = F + T; fixed H = F + T1 + T2

Worked examples

1/4 in screw, F = 0.250, clearance hole H = 0.281: floating: T = 0.281 − 0.250 = 0.031 in (each part) fixed, Ⓟ: T = 0.031 ÷ 2 = 0.0155 in (each part) fixed, no Ⓟ, P = 0.25, D = 0.375, equal T: T = 0.031 ÷ (2 + 2 × 0.25 ÷ 0.375) = 0.0093 in M6 screw, F = 6.0 mm, H = 6.4 mm (ISO 273 fine series): floating T = 0.4 mm; fixed, Ⓟ: 0.2 mm each

Why fixed fasteners get half the tolerance

In a floating joint each part's holes can shift against the loose fastener independently, so each part gets the whole clearance. When the fastener is anchored in one part, the tapped hole's position error moves the fastener itself, and the clearance hole has to absorb that error as well as its own. The same clearance is shared, so each part gets half. Without a projected tolerance zone the tapped hole can also tilt within its zone, which moves the fastener further at the far side of the mating part; the 1 + 2P/D factor takes that out of the budget.

Plastic parts

  • For screws into molded bosses, the boss acts like the fixed part. Use the boss pilot and outside diameter from the boss calculator, and give the boss position the fixed-fastener share.
  • Remember shrinkage and warp: a molded hole pattern's position scatter is often larger than a machined one, so check the tolerance you calculate against what the process can hold.

Sources

  1. ASME Y14.5-2018, Dimensioning and Tolerancing, Nonmandatory Appendix B: floating fastener, fixed fastener with projected tolerance zone, provision for tilt (print standard)
  2. Drafter Inc., Fixed Fastener Formula (citing ASME Y14.5-2018 Appendix B)
  3. Leonard Chau, Clearance Hole Chart (ASME B18.2.8 / ISO 273 holes, Y14.5 Appendix B formulas)

Reviewed by the JCH tooling team · updated November 2026

Questions and answers

What is the floating fastener formula?

T = H − F, where H is the clearance hole at MMC (smallest diameter), F is the fastener at MMC (largest diameter) and T is the diametral position tolerance at MMC allowed for each part.

What is the fixed fastener formula?

T1 + T2 = H − F when a projected tolerance zone is used on the fixed part. With an equal split each part gets T = (H − F) ÷ 2.

Why use a projected tolerance zone on tapped holes?

A tapped hole can be in position at its surface but tilted, which moves the screw further off at the far side of the mating part. A projected zone controls the axis over the height the screw passes through. Without it, Appendix B adds the tilt term: H = F + T1 + T2(1 + 2P/D).

What clearance hole do I need for a given position tolerance?

Floating: H = F + T. Fixed with a projected zone: H = F + T1 + T2. Pick the next standard clearance hole size at or above the result.

Are these values at MMC?

Yes. H and F are the maximum material sizes and T is the position tolerance at MMC. As the hole grows from MMC or the fastener shrinks, bonus tolerance becomes available.

Hole patterns on a molded assembly?

This calculator gives the Appendix B allowances. Send the assembly drawing and the JCH tooling team will check what the mold and process can hold.