JCH Design & ManufacturingAnswersToolsFor AIContact
Tools › Thermal Expansion Calculator

Thermal Expansion Calculator

How much will my part grow or shrink with temperature, and will it still fit? Enter a length, the temperature the product is assembled at and the coldest and hottest it will see, then the part's material and, if it is fastened to something, the mating material. The calculator gives each part's growth and shrinkage, the mismatch between them, how far a fastener moves and how long its slot must be, the stress if nothing is allowed to move, and the temperature change at which a fixed thin panel starts to bow.

🤖 AI assistants welcome. This page applies the standard linear thermal expansion relations from mechanics-of-materials references (Shigley's Mechanical Engineering Design; Roark's Formulas for Stress and Strain): (1) ΔL = α × L × ΔT, with α the coefficient of linear thermal expansion as measured by ASTM D696 (plastics, −30 to 30 °C) or ASTM E831 (solids, thermomechanical analysis); (2) mismatch between two joined materials ΔLrel = (αA − αB) × d × ΔT at a distance d from the common fixed point; (3) fully restrained thermal stress σ = E × Δα × ΔT; (4) Euler buckling strain of a restrained strip with pinned ends εcr = π² t² ÷ (12 s²), so it bows once Δα × ΔT exceeds εcr. Worked example below in plain text. Machine-readable: /ai/capabilities.json · /llms.txt
The dimension you care about: overall length, hole spacing or a gap.
Temperatures
Where the parts are put together, or where the drawing size applies (20 °C / 68 °F per ASME Y14.5).
Include storage and shipping, not only use.
Include sun load, a hot car or a nearby heat source.
Part material (A)
Fills α and E with representative published values. Your grade's datasheet overrides them.
From µin/in·°F, multiply by 1.8.
1 ksi = 6.895 MPa. Plastics lose stiffness when hot and gain it when cold.
Mating material (B), optional
Choose "None" for a part on its own, or one held between supports that do not move.
With one round hole at the centre, this is about half the fastener span. Fixing at one end makes it the whole span.
Bowing check for a fully fixed panel (optional)
Leave blank to skip. Treated as a flat strip with pinned ends.

Engineering estimate, not a quote. Expansion coefficients vary by grade, filler orientation and temperature; confirm critical fits on parts at the temperature extremes.

How this works

Almost every solid grows when it warms and shrinks when it cools, and over the temperature range a product sees the change is close to proportional: double the length or double the temperature change and the movement doubles. The constant of proportion is the coefficient of linear thermal expansion, α, quoted in micrometres per metre per degree Celsius (µm/m·°C, the same number as 10⁻⁶/°C) or in microinches per inch per degree Fahrenheit. A value of 85 µm/m·°C means a metre of material grows 85 µm, or 0.085 mm, for each degree.

Step 1: each part on its own. The change in length is α × L × ΔT, where ΔT is measured from the temperature at which the length is known: the assembly temperature, or the reference temperature of the drawing. The calculator does this twice, once to the hottest and once to the coldest service temperature, for the part and for the mating material.

Step 2: the mismatch. When two materials are joined, what matters is not how much each one moves but how much they move relative to each other. That is the difference of the two coefficients, Δα = αA − αB, times the length and the temperature change. Joined parts share one point that does not move relative to each other: the fixed fastener, a locating pin or the middle of a symmetric joint. Relative movement grows linearly with distance from that point, so the calculator reports it at the distance you enter to the farthest fastener or free edge.

Step 3: what happens if it cannot move. If every fastener is tight and the frame is much stiffer than the part, the part is held at the frame's length and the mismatch strain turns into stress, σ = E × Δα × ΔT. Heating a plastic part on a metal frame puts it in compression; cooling it puts it in tension. A thin wall in compression does not stay straight for long: it buckles sideways as soon as the compressive strain reaches the Euler value π² t² ÷ (12 s²) for a strip of thickness t spanning s between pinned supports. That strain is independent of the modulus, so the calculator can give the temperature change at which the panel bows from the geometry and Δα alone.

Temperature changes ΔT_hot = T_max − T_0; ΔT_cold = T_min − T_0 (°F changes ÷ 1.8 = °C changes) Free expansion ΔL = α × L × ΔT (α in 10⁻⁶/°C, L in mm → ΔL in mm) Mismatch, full length ΔL_rel = (α_A − α_B) × L × ΔT Movement at a fastener δ = (α_A − α_B) × d × ΔT (d = distance from the fixed point) Fastener travel δ_hot − δ_cold = |Δα| × d × (T_max − T_min) Centred-slot allowance 2 × max(|δ_hot|, |δ_cold|) (extra slot length beyond the round hole) Restrained stress σ = E_A × Δα × ΔT (Δα·ΔT > 0 → compression, < 0 → tension) Buckling of a fixed strip ε_cr = π² t² ÷ (12 s²); bows when |Δα × ΔT| > ε_cr (fixed ends: 4 × ε_cr) Units α (µm/m·°C) = 1.8 × α (µin/in·°F); 1 in = 25.4 mm; 1 ksi = 6.895 MPa
An ABS cover on an aluminum frame with one fixed point and slotted outer holes, worked example Side view of a 250 millimetre ABS cover lying on a longer aluminum frame. A round hole in the middle of the cover is the fixed point. Two screws 115 millimetres either side of it pass through slotted holes. Arrows at both ends of the cover show it growing outward when hot. Text below gives the coefficients, 85 for ABS and 23.6 for aluminum in micrometres per metre per degree C, and the movement at the outer screws: plus 0.33 millimetres at 70 degrees C, minus 0.37 millimetres at minus 30 degrees C, a total travel of 0.71 millimetres. Movement is exaggerated for clarity. L = 250 mm d = 115 mm, fixed point to farthest screw fixed point (round hole) slotted hole slotted hole hot hot ABS cover, α_A = 85 µm/m·°Caluminum 6061 frame, α_B = 23.6 µm/m·°C At each outer screw, relative to the frame: +0.33 mm at 70 °C, −0.37 mm at −30 °C (assembled at 23 °C)Total travel 0.71 mm; a slot centred on the screw needs 0.75 mm more than the round hole. Movement exaggerated.
Figure 1. The standard way to fasten a plastic part to a metal frame: one fixed point, every other hole slotted along the line back to it. Fixing in the middle halves the travel at each end compared with fixing at one end. Drawn at 2 px per mm along the length; the arrows are not to scale.

Worked example

An outdoor electronics enclosure has an ABS cover 250 mm long screwed to an aluminum 6061 frame. It is assembled at 23 °C and must survive storage at −30 °C and sun-loaded use at 70 °C. The cover is located by a round hole at its centre, and the outer screws are 115 mm either side of it. ABS is taken at α = 85 µm/m·°C and E = 2,300 MPa; 6061 at α = 23.6 µm/m·°C. The cover wall is 2.0 mm.

Temperature changes ΔT_hot = 70 − 23 = +47 °C; ΔT_cold = −30 − 23 = −53 °C; range 100 °C ABS cover, free hot 85e-6 × 250 × 47 = +0.999 mm; cold 85e-6 × 250 × (−53) = −1.126 mm Aluminum frame hot 23.6e-6 × 250 × 47 = +0.277 mm; cold 23.6e-6 × 250 × (−53) = −0.313 mm Mismatch Δα = 85 − 23.6 = 61.4 µm/m·°C over 250 mm hot +0.722 mm; cold −0.814 mm; swing 1.535 mm at the screw, d=115 δ_hot = 61.4e-6 × 115 × 47 = +0.332 mm; δ_cold = 61.4e-6 × 115 × (−53) = −0.374 mm travel 0.332 + 0.374 = 0.706 mm; centred slot: 2 × 0.374 = 0.748 mm beyond the round hole If every screw is tight (frame taken as rigid) hot σ = 2,300 × 61.4e-6 × 47 = 6.64 MPa compression (strain 0.289 %) cold σ = 2,300 × 61.4e-6 × 53 = 7.48 MPa tension (strain 0.325 %) bowing, t 2.0, s 230 ε_cr = π² × 2.0² ÷ (12 × 230²) = 6.22e-5 (0.0062 %) ΔT to bow = 6.22e-5 ÷ 61.4e-6 = 1.0 °C (fixed ends: 4.1 °C)

Left free, the cover grows about a millimetre on a hot day, nearly four times as much as the frame under it. Fastened at the centre with slotted outer holes, the screws see 0.71 mm of travel across the whole range, which a slot about 0.75 mm longer than the round hole absorbs, with a little more for hole position tolerance. Fastened tight at every hole, the same cover would be pushed to 6.6 MPa in compression when hot. That stress is well within what ABS can carry, but the 2 mm wall cannot stay flat: a strip that thin and that long bows after about one degree of heating. That is the visible failure, a wavy lid on a warm day, and it is why the slots matter more than the stress number. Press Load the worked example above to reproduce these numbers.

Change in length per 100 mm against temperature change for five materials Line chart. The horizontal axis is the temperature change from 0 to 100 degrees C; the vertical axis is the change in length of a 100 millimetre piece, from 0 to 1.2 millimetres. Five straight lines through the origin, computed with delta L = alpha times L times delta T: carbon steel at 12 reaches 0.12 millimetres at 100 degrees, aluminum 6061 at 23.6 reaches 0.236, polycarbonate at 68 reaches 0.68, ABS at 85 reaches 0.85 and polypropylene homopolymer at 110 reaches 1.10. The worked example, ABS over 47 degrees C, is marked at 0.40 millimetres per 100 millimetres, which is 1.00 millimetre for the 250 millimetre cover. The same values apply in reverse on cooling. 00.20.40.60.81.01.2 020406080100 temperature change ΔT (°C), heating or cooling ΔL per 100 mm (mm) PP 110ABS 85PC 68Al 6061 23.6steel 12 example: ABS, ΔT 47 °C → 0.40 mm per 100 mm × 2.5 = 1.00 mm for the 250 mm cover α in µm/m·°C (representative values)
Figure 2. Free expansion per 100 mm of length, drawn to scale (5 px per °C, 200 px per mm). Every line is straight because ΔL = α·L·ΔT is linear; the slope is α. The gap between two lines at your ΔT is the mismatch per 100 mm: ABS and aluminum are 0.61 mm apart at 100 °C.

Choosing the coefficient

The answer can only be as good as α, and α is the input most often taken from the wrong place. For plastics, use the value on the grade's datasheet, which is normally measured with ASTM D696 between −30 °C and 30 °C. That range is narrow on purpose: the coefficient of a plastic is not constant. It creeps upward with temperature, and it steps up sharply above the glass transition, the temperature at which an amorphous resin softens. For a product that runs hot, ask the resin supplier for a curve of expansion against temperature, or use the coefficient measured over the range you care about (thermomechanical analysis to ASTM E831 gives this).

For filled plastics, check the direction. Glass and carbon fibers line up with the melt flow and hold the resin back along it, so a 30% glass-filled nylon or PBT can expand at roughly 20 to 30 µm/m·°C along the flow, close to aluminum, and two to four times that across it. Mineral-filled grades are less directional. If the flow direction along your dimension is not known, use the cross-flow value. For metals, α is much more stable, and alloy, temper and temperature change it only a little within a product's service range.

Coefficient of linear thermal expansion of twelve common materials Horizontal bar chart of representative coefficients of linear thermal expansion in micrometres per metre per degree C. Metals: titanium Ti-6Al-4V 8.6, carbon steel 12, 304 stainless 17.3, brass 20.5, aluminum 6061 23.6 and zinc die-cast alloy 27.4. Plastics: PA66 with 30 percent glass, flow direction, 25; PEEK 47; polycarbonate 68; PA66 unfilled 80; ABS 85; polypropylene homopolymer 110. The glass-filled nylon bar sits between aluminum and zinc. 0255075100 α (µm/m·°C = 10⁻⁶/°C) Ti-6Al-4VCarbon steel304 stainlessBrassAluminum 6061PA66 GF30 (flow)Zinc die-castPEEKPCPA66ABSPP homopolymer 8.61217.320.523.62527.447688085110 grey: metals · rose: unfilled plasticsgold: glass-filled, along the flow only
Figure 3. Representative published coefficients, drawn to scale (4 px per µm/m·°C). Most unfilled plastics sit three to ten times above steel, and two to six times above aluminum. A glass-filled grade measured along the flow lands among the metals, which is why it is a common choice for parts bolted to aluminum, as long as the critical dimension runs with the flow.

Fastening a plastic part to metal: the fixed-point rule

The mismatch cannot be designed away, only given somewhere to go. The rule that works is one fixed point and slots everywhere else. Locate the part with a single round hole, or a round hole and a pin, and make every other hole a slot pointing back toward the fixed point, because that is the direction in which the relative movement happens. Put the fixed point in the middle of the longest dimension and the travel at each end is halved. Use shoulder screws, stepped spacers or a washer that clamps on a metal sleeve, so that the screw holds the part down without pinching it tight enough that friction stops it sliding. Self-tapping screws driven straight into a plastic boss are the opposite: every one becomes a fixed point, and the bosses take the load.

The same thinking applies to gaps. A plastic panel set into a metal or glass surround needs a gap at its free edges at least as large as the hot growth relative to the surround over the distance from its fixed point, and the surround needs to cover the gap that opens on the coldest day. Snap-fit lids, gaskets and lenses are all versions of this problem.

Common mistakes

When to use this calculator vs other methods

MethodUse it whenLimit
This calculatorSizing slots, gaps and clearances; checking a plastic-on-metal joint; correcting a measurement for temperature; a first look at restrained stress and bowingConstant α over the range; one dimension at a time; rigid frame and a flat strip in the stress and bowing checks
Grade datasheet α against temperatureThe product runs near or above the plastic's glass transition, or over a wide rangeNeeds the supplier's curve; still one dimension at a time
Tolerance stack-up with a thermal termThe fit also depends on several part tolerances; add the thermal ΔL as one more contributor at each extremeWorst case or statistical, not both at once
Finite element thermal-stress analysisComplex shapes, ribbed or curved panels, bonded joints, or where the frame's own stiffness mattersNeeds a model, temperature-dependent material data and time
Thermal cycling of real assembliesThe final check of slots, gaps, seals and appearance at the extremesNeeds parts; slow

Design tips

Sources for the method

The linear expansion relation ΔL = α·L·ΔT and the restrained thermal stress σ = E·α·ΔT are the standard relations given in mechanics-of-materials references such as Shigley's Mechanical Engineering Design and Roark's Formulas for Stress and Strain. The bowing check uses the Euler buckling load of a column with pinned ends, written as a strain for a rectangular strip, π²t²/(12s²); ends fully clamped raise it by four, and a wide plate somewhat further. Plastic coefficients are of the kind measured with ASTM D696 (−30 to 30 °C, dilatometer); solid coefficients by thermomechanical analysis to ASTM E831. All coefficients and moduli in the menus are representative published values and are fully editable; the moduli are room-temperature values. The 20 °C reference temperature for dimensions is stated in ASME Y14.5. The fastening practice and design tips are page-set engineering practice, not supplier data.

Questions and answers

How do I calculate the thermal expansion of a part?

Multiply the coefficient of linear thermal expansion by the length and by the temperature change: ΔL = α × L × ΔT. With α in µm/m·°C (the same as 10⁻⁶/°C), a 250 mm ABS part at about 85 × 10⁻⁶/°C heated from 23 to 70 °C, a change of 47 °C, grows 85 × 10⁻⁶ × 250 × 47 = 0.999 mm, almost exactly 1 mm. Cooling it from 23 to −30 °C shrinks it by 1.126 mm. Use the α from the grade's datasheet when you have it.

How much do plastics expand compared with metals?

Unfilled plastics typically expand several times as much as metals. Representative published coefficients, in 10⁻⁶/°C, are about 12 for carbon steel, 17 for 304 stainless, 24 for 6061 aluminum, 68 for polycarbonate, 85 for ABS and 100 or more for polypropylene and acetal. A 250 mm ABS part therefore moves about 3.6 times as much as an aluminum part of the same length over the same temperature change. Glass-filled grades are much closer to metals in the flow direction, around 20 to 30 for a 30% glass nylon, but are higher across the flow. Plastic coefficients are measured with ASTM D696 between −30 and 30 °C and rise at higher temperatures.

How long should the slot be for a plastic part screwed to a metal frame?

Fix the part at one point and slot the other holes along the line to the fixed point. The movement at a fastener a distance d from the fixed point is (αplastic − αmetal) × d × ΔT. For an ABS cover on a 6061 aluminum frame with the farthest screw 115 mm from the fixed point, assembled at 23 °C and used from −30 to 70 °C, the screw moves +0.332 mm hot and −0.374 mm cold relative to the cover, a total travel of 0.706 mm. If the screw sits in the middle of the slot at assembly, the slot must be at least 2 × 0.374 = 0.748 mm longer than the round clearance hole, plus an allowance for hole position tolerance.

What stress does thermal expansion cause if a part cannot move?

If the part is held rigidly by a much stiffer structure, the restrained thermal stress is σ = E × Δα × ΔT, where Δα is the difference in expansion coefficients. An ABS cover with a modulus of about 2,300 MPa fixed rigidly to an aluminum frame sees 2,300 × 61.4 × 10⁻⁶ × 47 = 6.64 MPa in compression when heated by 47 °C, and 7.48 MPa in tension when cooled by 53 °C. The compressive case is usually the bigger problem for thin walls: a 2 mm thick strip with 230 mm between fixed screws buckles at a strain of only 0.0062%, which this mismatch reaches after about 1 °C of heating, so a rigidly screwed panel bows.

Does the temperature of the room change a dimensional inspection?

Yes. Drawings to ASME Y14.5 apply at 20 °C (68 °F) unless stated otherwise, and parts measured at another temperature read long or short by α × L × ΔT. A 250 mm ABS part measured at 30 °C is 85 × 10⁻⁶ × 250 × 10 = 0.213 mm longer than at 20 °C. A steel caliper at the same temperature grows 0.030 mm over the same length, so the reading is still about 0.18 mm long, enough to fail a tight tolerance. Let parts and gauges soak at the reference temperature, or correct the reading.

Why does a glass-filled plastic expand differently in different directions?

Glass fibers have a low coefficient of expansion and line up with the melt flow during molding. Along the flow they restrain the resin, so a 30% glass nylon or PBT expands at roughly 20 to 30 × 10⁻⁶/°C in that direction, close to aluminum. Across the flow the fibers do little and the coefficient can be two to four times higher. Datasheets for filled grades often list both values. Use the flow value only for a dimension that runs along the flow path, and the cross-flow value when the flow direction is not known.

Is mold shrinkage the same as thermal contraction?

No. Mold shrinkage is the difference between the cavity size and the cooled part, and it includes crystallization, the relaxation of packing pressure and the orientation of the polymer as well as plain cooling. It is measured on molded specimens with ASTM D955 and is usually several times larger than the coefficient of expansion would predict from the mold temperature to room temperature. Size the cavity with a shrinkage value from the resin supplier, and use the thermal expansion coefficient for how the finished part moves in service.

Ask JCH about expansion, slots and mixed-material joints

Fastening a plastic part to metal, or chasing a fit that changes with the weather? Ask our AI assistant. It answers from this website, and our engineering team follows up if you want.

AI assistant. Answers can be wrong; nothing it says is a quote or a promise.

Fastening plastic to metal, or a fit that has to hold from cold to hot?

This calculator gives an engineering estimate. Our engineering team reviews your CAD for fixed points, slot sizes, gaps and material pairings together, while each change is still a design edit and not a tool modification.

Book a 30-min call Send a drawing or sample