Ultrasonic Weld Energy Director Calculator
For a butt, step or tongue-and-groove joint, make the energy director's base 20 to 25 percent of the wall thickness at the joint and its height half the base (90° apex, amorphous resins) or 0.866 times the base (60° apex, semi-crystalline resins, and per Dukane also polycarbonate and acrylic), then hold it at or above 0.010 in (polystyrene-type resins) or 0.015 in (polycarbonate and semi-crystalline resins). Those are the Dukane and Branson joint-design proportions. For a shear joint there is no director: the calculator looks up the interference per side from Branson's table by the largest part dimension. Enter your wall, resin and joint below to get height, base, melt volume and, where it applies, interference.
These dimensions come from the starting proportions that welder makers and a resin maker publish. They set up a first weld trial; the welder supplier's application lab, the resin grade and test welds settle the final joint, and these numbers commit no one to a design.

How this works
An energy director is a small triangular ridge molded along one of the two mating faces. When the horn starts vibrating, the only contact is the sharp peak, so heat builds there first and the ridge melts and spreads across the joint. The Branson bulletin Part Design for Ultrasonic Welding describes it as "a raised triangular bead of material molded on one of the joint surfaces" whose job is "to concentrate the energy to rapidly initiate the softening and melting of the joining surface." Sizing it comes down to three numbers: how wide the base is, how tall the peak stands, and the angle at the peak. All three follow from the wall thickness W and the resin family.
Base width. The DuKane Guide to Ultrasonic Plastics Assembly, excerpted in Plastics Decorating (April/May 2002), states: "The width of the energy directors base is between 20 percent and 25 percent of the thickness of the wall." A 2019 ASSEMBLY magazine article on joint design phrases the same band as a ceiling: "no more than 20 percent to 25 percent of the wall thickness." The calculator reports both ends and headlines the upper one, 0.25W. That choice is our reading; we picked it because at a 90° apex it lands exactly on Branson's height of W/8, so two independent guides agree at that point.
Apex angle and height. In the Dukane excerpt the basic director for an amorphous resin "is a right triangle with the 90-degree angle at the apex," which "makes the height one-half the base width." For "polycarbonate, acrylics, and semi-crystalline resins" the director becomes an equilateral triangle, which "makes the height 0.866 times the base width." Branson's figures carry the footnote "Included angle = 90º for amorphous resins and 60º for semi-crystalline resins," and its text adds that "the dimensions given utilize a 90o included angle. This angle may change as wall thickness varies." The ASSEMBLY article names ABS and polystyrene for the 90° form and nylon and polyethylene for the 60° form. So the angle selector defaults to 90° for the easy-welding amorphous family and 60° for the other two. The two guides part ways here. Branson's footnote puts amorphous resins at 90° and names polycarbonate as a high-temperature amorphous resin; it does not mention acrylic, so placing acrylic in that 90° group is our reading. Dukane moves both to 60°. We default to Dukane because it names those resins outright; switch the angle to 90° if your welder supplier follows the Branson figure.
Minimum height. Proportions alone fail on thin walls, because the bead shrinks with the wall. Branson sets floors: "a minimum height of 0.010 inch (0.25 mm) is suggested" for "a relatively easy-to-weld resin (e.g., polystyrene which has high modulus [stiffness] and low melt temperature)," whereas "a semi-crystalline or high-temperature amorphous resin (e.g., polycarbonate) would require a minimum height of 0.015 inch (0.4 mm)." The Solvay Specialty Polymers bulletin on ultrasonic welding, which uses its semi-crystalline Amodel polyphthalamide as the example, asks that "the height of the director should be at least 0.4 mm (15.7 mils)" and that the included angle not exceed 90° "for increased strength." The calculator uses 0.010 in for the easy-welding amorphous family and 0.015 in (0.381 mm) for the other two. Extending the polystyrene floor to ABS and the polycarbonate floor to acrylic is our reading; Branson names only polystyrene and polycarbonate. When the proportional height falls below the floor, the headline switches to the floor height and widens the base to keep the apex angle, then warns you if that base now exceeds a quarter of the wall.
Thin walls and the chisel director. Branson says a chisel director is “typically used when nominal wall thickness is 0.060 inch (1.524 mm) or less”: a standard director there "will be too small (less than 0.010 inch/0.254 mm tall), thus resulting in lower weld strengths." Its alternative is a chisel director whose knife edge "can be 0.015 inch to 0.020 inch (0.381 to 0.508 mm) tall and should utilize a 45o angle," with a textured mating surface, since "weld strength will be limited to weld width." The calculator flags every wall at or under 0.060 in so you can weigh that option.
Thick walls. The Dukane excerpt caps the size: for the 90° form, "the size of this energy director can range from 0.005 to 0.030 high and from 0.010 to 0.060 wide," and for the 60° form "the base width can range from 0.010 to 0.050." The excerpt prints those without a unit; reading them, and every other unitless Dukane figure on this page, as inches is our reading, since the same text gives wall minimums such as 0.080 to 0.090 that only make sense in inches. Past the cap, "two smaller parallel energy directors should be used." With a base of a quarter of the wall, the 0.060 in cap is reached at a 0.240 in (6.1 mm) wall for 90°, and the 0.050 in cap at a 0.200 in (5.08 mm) wall for 60°.
Melt volume. The triangle's cross-section, B × H ÷ 2, is the plastic available to melt per unit length of joint. Multiply by the weld-line length for the total. Dividing that area by the wall turns it into the thickness of the layer the director would make if it flowed evenly from edge to edge. These are geometry, not weld-strength predictions, and the layer figure is our reading: the guides do not print a volume rule. It is useful for comparing designs, checking that a flash trap has room, and seeing how much more plastic a shear joint melts.
Proportions by joint type, with their stated conditions
| Joint | Published figure | Condition as printed | Source |
|---|---|---|---|
| Butt, director | base 20–25% of W; H = ½B or 0.866B | 90° for amorphous; 60° for polycarbonate, acrylics and semi-crystalline | Dukane excerpt |
| Butt, director | H = W/8; “after” sketch labeled W/64 | drawn with a 90° included angle; 60° footnoted for semi-crystalline | Branson Figure 2 |
| Any director | H 0.25–0.75 mm | "a simple energy director is usually between 0.25-0.75mm tall"; strength-only bond | Dukane blog |
| Any director | H about 0.3–0.7 mm, 60–90° point | "scaled to the size of the part" (Michael Lindsay, Herrmann Ultrasonics) | ASSEMBLY 2019 |
| Step | tongue height and width W/3; groove 0.002–0.004 in wider, 0.005–0.010 in deeper than the tongue (Dukane prints no unit; inches is our reading) | minimum wall 0.080 to 0.090, no unit printed (Dukane); Branson draws W ≥ 0.080 in, a W/3 dimension with a 0.023 in (0.6 mm) minimum, and a W/8 + 0.010–0.025 in gap that leaves a shadow line | Dukane excerpt; Branson Figure 3 |
| Tongue and groove | tongue height and width W/3; groove 0.004–0.008 in wider and 0.005–0.010 in shallower than the tongue (Dukane prints no unit; inches is our reading) | minimum wall 0.120 to 0.125, no unit printed (Dukane); Branson draws W ≥ 0.125 in (3.2 mm), a W/2 label across the tongue, a W/3 dimension at the groove and 3–5° draft | Dukane excerpt; Branson Figure 4 |
| Shear | interference per side by largest dimension; depth 1.25W | "for joint strength meeting or exceeding that of the wall"; not for parts of 3.5 in or more | Branson; Solvay Table 1 |
Two of those rows disagree with each other and the page shows both rather than choosing silently. For the tongue, Dukane writes "the height and width of the tongue are both one-third the thickness of the wall," while Branson's Figure 4 marks W/2 across the tongue; the calculator prints the Dukane W/3 and mentions the Branson label. Minimum walls also differ by source: ASSEMBLY gives 0.062 in for a step joint and 0.09 in for tongue and groove, and Lindsay says the tongue-and-groove form "requires a minimum wall thickness of 3 millimeters." The calculator warns below 0.080 in for a step and 0.120 in for tongue and groove, the low ends of the Dukane ranges, read as inches (our reading).
The shear joint: interference instead of a bead
Branson explains why semi-crystalline resins can disappoint with a director: they "change rapidly from a solid to a molten state, and back again, over a relatively narrow temperature range," so melt from the bead "could re-solidify before fusing with the adjoining interface," and "the weld strength in a semi-crystalline resin could be limited to the base width of the energy director." Its remedy is "a shear joint configuration ... where geometry permits." The Dukane blog makes the same point, calling shear joints "particularly effective at welding semi-crystalline resins that struggle to bond with energy directors," and defines the joint as "an intentionally molded interference fit between your two plastic parts."
The weld forms along the overlap as the top part telescopes down. Branson's table sizes the overlap from the largest part dimension:
| Maximum part dimension | Interference per side | Part dimension tolerance |
|---|---|---|
| less than 0.75 in | 0.008 to 0.012 in (0.2 to 0.3 mm) | ±0.001 in (±0.025 mm) |
| 0.75 to 1.50 in | 0.012 to 0.016 in (0.3 to 0.4 mm) | ±0.002 in (±0.050 mm) |
| 1.50 to 3.50 in | 0.016 to 0.020 in (0.4 to 0.5 mm) | ±0.003 in (±0.075 mm) |
| 3.5 in or greater | shear joint not recommended; Branson suggests an energy director joint instead | |
Branson's own millimeter labels on the row limits (18, 35, 38 and 90 mm) do not convert exactly from the inch limits; Solvay's Table 1 prints the same interference bands with limits of 19 and 38 mm. The calculator selects rows in inches. Sending a part that measures exactly 1.50 in to the middle row is our reading, since both rows print that value. Branson rules the joint out at "a maximum dimension of 3.5 inch or greater, sharp corners, or irregular shapes," citing "difficulty in holding the molding tolerances necessary to obtain consistent results." Which dimension counts as "maximum" is not defined; we use the longest overall size of the joint outline, our reading.
Depth sets strength. Branson: "For joint strength meeting or exceeding that of the wall, a depth of 1.25X the wall thickness is recommended." Solvay's Figure 4 labels the depth 1.25W to 1.50W, and ASSEMBLY says "a weld depth of 1.25 to 1.5 times the wall thickness of the part will create a weld that is nearly as strong as the surrounding wall." Branson also draws a minimum lead-in of 0.040 in (1.016 mm), and stresses that "the shear joint requires rigid side wall support to prevent deflection during welding." For the melt figure, the calculator multiplies interference by the 1.25W depth: the band of plastic one side must give up. That product is our reading of the geometry, not a printed rule.
Worked example: one 80 × 40 mm housing, three ways
A rectangular housing 80 mm by 40 mm with a 2.5 mm wall at the joint has a weld line of 2 × (80 + 40) = 240 mm. Example 1 and Example 2 above load the first and third cases; Example 3 loads Branson's thin-wall case.
Case 1 shows why the low end of the Dukane band needs a second look on a 2.5 mm wall: half of a fifth of the wall is 0.250 mm, a hair under Branson's polystyrene-type floor. Case 2 shows that the two guides disagree for the 60° form: keeping Branson's W/8 height and narrowing the apex gives a smaller bead than Dukane's base rule and misses the floor. Case 3's melt band (our reading) is about 7.5 to 9.4 times the plastic of Case 2 along the same 240 mm, because the overlap runs the full weld depth instead of a sub-millimeter triangle; leave room in the part for that displaced plastic. Change the outline to 100 mm long and it reaches 3.94 in, past Branson's 3.5 in limit, so the shear option drops out.
Common mistakes
- Scaling the bead off the part size instead of the wall. Every proportion here is a fraction of the wall at the joint. A large housing with a thin wall still gets a small director.
- Ignoring the floor on thin walls. On anything near 1.5 mm, the proportional height drops under 0.010 in. Check the floor and the chisel option before cutting steel.
- Rounding the peak. Branson: "The peak of the energy director should be as sharp as possible; energy directors that are round or flat at their peak will not flow as efficiently." Lindsay adds that a sharp point "usually means that’s an EDM feature in your mold."
- Leaving the parts to find each other. A plain butt joint has no alignment. Branson asks for "pins and sockets, aligning ribs, tongue and groove designs, or fixturing," and adds "knockout pins should not be placed in the weld area."
- Choosing a shear joint for a big or angular outline. The table stops at 3.5 in, and sharp corners or irregular shapes are excluded by the same sentence.
- Fixturing a shear joint loosely. Without a nest that conforms closely to the lower wall, the wall bows out and the interference is lost.
Where this calculator fits
| Option | Good for | Gaps |
|---|---|---|
| This calculator | First-pass director, tongue and interference sizes from a wall and a resin family; comparing melt between joint types | Weld strength, amplitude, horn design, near-field or far-field effects, grade-specific behavior |
| Welder maker's application lab | Feasibility, horn and fixture design, test welds on real parts | Needs molded samples or prototypes |
| Resin supplier bulletin | Grade-specific minimum heights and joint advice, as in the Solvay sheet | Covers that supplier's grades only |
| Snap fits or another joining method | Parts that must come apart, or resin pairs that will not weld; see the snap-fit cantilever calculator | No hermetic seal from the latch itself |
The wall the director rides on comes first: if the joint wall is thinner or thicker than the rest of the part, check it with the wall thickness checker before sizing the bead, since every figure here scales from it.
Sources for the method. Butt, step, tongue-and-groove, chisel and shear proportions, minimum heights, the interference table, depth of weld and the 3.5 in limit: Branson, Part Design for Ultrasonic Welding (bulletin, copy hosted by Sonic Power). Base 20–25% of the wall, the half-base and 0.866 heights, maximum sizes, tongue and groove sizes: DuKane Guide to Ultrasonic Plastics Assembly as excerpted in Plastics Decorating. The 0.25–0.75 mm height and the shear-joint definition: Dukane, Joint Design for Ultrasonic Plastic Bonding. Angle by resin, the 20–25% ceiling, 0.01–0.04 in heights, step and tongue minimum walls, 1.25–1.5W depth and the Herrmann Ultrasonics figures: ASSEMBLY, Joint Design for Ultrasonic Welding (September 6, 2019). The 0.4 mm floor, 1.25–1.50W depth and Table 1: Solvay Specialty Polymers, Ultrasonic Welding technical bulletin. Millimeters per inch, 25.4 and exact: NIST SP 811, Appendix B.9. Each source here was retrieved on November 20, 2026, and the quoted words match the retrieved text word for word.
Reviewed by the JCH tooling team · updated November 2026.
Energy director and weld joint questions
How tall should an energy director be?
Scale it from the wall where the two parts meet. With a 2 mm wall, a 90-degree bead works out to roughly 0.20 to 0.25 mm on the Dukane rule, which is right at or below the 0.25 mm floor Branson gives for easy resins, so the floor would set it. Welder makers' own rules of thumb for a simple bead land between about a quarter and three quarters of a millimeter.
Why do semi-crystalline plastics get a sharper 60-degree director?
Nylon, acetal and polypropylene go from solid to liquid over a narrow band of temperature, so plastic squeezed off a blunt bead can freeze before it wets the opposite face. Dukane's answer is a bigger bead with a steeper point, which partly sinks into the mating face early in the weld so less melt freezes too soon. Where the outline allows, the guides steer those resins toward a shear joint instead.
What if my wall is too thin for a standard director?
Below about 1.5 mm, the proportional bead comes out shorter than a quarter of a millimeter and gives a weak weld. Branson's fix is a knife-edge bead around 0.4 to 0.5 mm high with a 45-degree angle, paired with a textured face on the other part. Expect the joint to be only as strong as that narrow weld line.
How much interference does a shear joint need?
It grows with part size. Branson pairs parts under three quarters of an inch with about 0.2 to 0.3 mm on each side, mid-size parts up to an inch and a half with 0.3 to 0.4 mm, and parts up to three and a half inches with 0.4 to 0.5 mm. Larger outlines are outside that table and go back to a bead-type joint.
How do I work out the melt volume of a director?
Treat the bead as a triangle: half of base times height gives square millimeters, which equals cubic millimeters per millimeter of seam. Multiply by the seam length. A 0.625 by 0.3125 mm bead around a 240 mm seam holds about 23 cubic millimeters, a useful check on whether the flash trap has space.
Which part should carry the energy director?
Branson's rule is that either half will do. When the halves are different materials, its practice is to mold the bead on the half with the higher melt temperature and the stiffer plastic, and Solvay's bulletin gives the same advice.
When is a step or tongue-and-groove joint worth the extra wall?
Pick a step when the outside seam is cosmetic and flash must stay hidden; pick tongue and groove when flash has to be trapped on both faces or a low-pressure seal is needed. Both locate the halves. The trade-off is wall: about 2 mm for a step and about 3 mm for tongue and groove, plus a weld area smaller than a full butt joint.
Ask JCH about a weld joint
Have a lid, a housing wall and a resin in mind? Describe the joint in the box. An AI assistant replies, and after its first answer it offers an optional field for an email address if you want someone to follow up.
Answers are generated by AI, so check anything you build from them; none of them is an offer or a commitment.
Designing a housing that will be welded shut?
Send the joint section, the resin and the seal or strength target. We will go over the director, step and interference sizes with you against these published proportions, and point out which ones only a weld trial can confirm, before any mold steel gets machined.
Book a free 30-minute first consultation Send a joint section