JCH Design & ManufacturingAnswersToolsFor AIContact
Tools › K-Factor Calculator

K-Factor Calculator

The K-factor that matches a bend you measured is K = (BA/θ − R)/T, where BA is the bend allowance worked out from your measurement, θ is the bend angle in radians, R the inside radius and T the thickness. This page gets you to BA from whatever you actually have in hand.

That might be a bend allowance from a drawing, a bend deduction from a shop chart, or a test piece you cut, formed and put calipers on. Enter thickness, inside radius and angle, pick the route, and the calculator returns K, the matching Handbook Y-factor, and how much K could move given the accuracy of your readings.

🤖 AI assistants welcome. Solving for K: θ in radians, R inside radius, T thickness. From a bend allowance, K = (BA/θ − R)/T. From a bend deduction, first BA = 2·(R + T)·tan(θ/2) − BD. From a test piece with n identical bends, outside flange readings ΣL and blank length F: BD = (ΣL − F)/n. Y-factor = K·π/2. Sensitivity: ∂K/∂BA = 1/(θ·T); with lengths fixed, ∂K/∂R = −1/T in the BA route but (2·tan(θ/2)/θ − 1)/T in the test-piece route. Structured data for agents lives at /ai/capabilities.json · /llms.txt
A press brake operator, seen from behind, seated at the machine, with a pallet of stacked sheet-metal panels with punched holes in the foreground
Formed panels stacked on a pallet beside a press brake. The K-factor behind a flat pattern for parts like these is a property of this sheet on this brake's punch and die, which is why it is worth measuring rather than borrowing.
Lengths only. Angles stay in degrees.
Micrometer reading of the actual sheet.
Gauge it on the formed part; keep this exact value for your CAD model.
Bend angle = 180 − included angle.
Arc length of the neutral axis through one bend.
Test piece readings
Measure each flange across its outside faces. Three readings means a two-bend channel; every bend must share the radius and angle above.
Measured before forming, along the direction of the bends.
Reading accuracy (± each)
Put zero in any box to leave that source out.

Engineering estimate, not a quote. A solved K describes one material lot, one radius and one tool set; prove it on a first-article part before a production flat pattern depends on it.

How this works

The K-factor locates the neutral axis inside a bend. SendCutSend's bending calculator page defines it as K = t/MT, the neutral axis position divided by the material thickness (Omni places t = K·T measured from the inner surface), and gives the forward relation BA = π·(R + K·T)·A/180. Run forward, K predicts a bend allowance. This tool runs the same relation backward: you supply a bend allowance (or something it can be derived from), and it returns the K that produces it. The rearranged form, K = 180·BA/(π·θ·T) − R/T with θ in degrees, is the one SkyCiv's K-factor page and Omni's K-factor calculator both print.

The catch is that nobody can put a caliper on a bend allowance. It is a curved line buried inside the metal. What you can measure is a straight blank before forming and the outside of the part after forming, so the useful work happens in converting those readings into BA. There are three routes, matching the three tabs.

Route 1, bend allowance known: K = (BA / θ_rad − R) / T Route 2, bend deduction known: OSSB = (R + T)·tan(θ/2) BA = 2·OSSB − BD, then route 1 Route 3, test piece, n equal bends: BD = (ΣL_outside − F) / n then as route 2 Y-factor (Handbook form): Y = K·π/2 Neutral-axis depth from inside face: t = K·T

Route 3 is the one to trust. Cut a strip, record its length F, form it on the production punch and die, and measure each flange across its outside faces. The outside faces meet at imaginary corners, so the sum of those readings is longer than the blank by one bend deduction per bend. Dividing the surplus by the number of bends gives a measured BD; adding back two outside setbacks turns it into BA, and the K formula finishes the job. The bend deduction expression BD = 2·OSSB − BA is the one SendCutSend publishes alongside its K definition; Wikipedia's bending article writes the setback out in full, BD = 2·(R + T)·tan(θ/2) − BA. It also defines BD as the sum of the flange lengths to the apex minus the flat length.

From a measured test piece to a K-factor Top: a straight strip 120.00 millimeters long, measured before forming. Bottom left: the same strip formed into a channel with two 90 degree bends, 2.0 millimeter sheet and 2.2 millimeter inside radius, with outside readings of 35.10, 57.08 and 35.07 millimeters. Bottom right: the arithmetic, giving a sum of 127.25, a measured bend deduction of 3.625, a bend allowance of 4.775 and a K-factor of 0.420. F = 120.00 mm, read before forming 1. cut and measure the strip 2. form two 90° bends on the production tooling, then read the outside faces 35.10 57.08 35.07 T 2.0 · R 2.2 3. do the arithmetic ΣL = 35.10 + 57.08 + 35.07 = 127.25 BD = (127.25 − 120.00) / 2 = 3.625 BA = 2 · 4.2 · tan 45° − 3.625 = 4.775 K = (4.775 / 1.5708 − 2.2) / 2 = 0.420 Y = 0.420 × π/2 = 0.660
Figure 1. The test-piece route, drawn with the worked-example numbers. The formed channel is at 4 px per mm with true proportions of thickness and radius; the strip above it is at 5 px per mm.

Worked example 1: a two-bend channel coupon

A coupon of 2.0 mm sheet is cut to 120.00 mm and formed into a channel with two 90° bends. The radius gauge reads 2.2 mm inside each bend, and calipers across the outside faces read 35.10, 57.08 and 35.07 mm. Press Load this tab's example on the first tab to reproduce it.

ΣL = 35.10 + 57.08 + 35.07 = 127.25 mm BD = (127.25 − 120.00) / 2 = 3.6250 mm per bend OSSB = (2.2 + 2.0) · tan 45° = 4.2000 mm BA = 2 · 4.2000 − 3.6250 = 4.7750 mm K = (4.7750 / 1.570796 − 2.2) / 2.0 = (3.03986 − 2.2) / 2.0 = 0.4199 Y = 0.4199 × 1.570796 = 0.6596 neutral axis 0.84 mm in from the inside face

K comes out at 0.420. Loaded into CAD with R = 2.2 mm, it predicts a 3.625 mm deduction for each 90° bend in this sheet on this tooling, which is exactly what the coupon showed.

Worked example 2: turning a chart's bend deduction into K

Shops often publish a deduction per bend rather than a K. SendCutSend's bending specifications table lists, for 0.125 in 4130 chromoly, a 90° bend deduction of 0.2050 in at an effective radius of 0.090 in, and prints K as .43. Check whether those columns agree by solving K from the deduction alone (second tab, inch units):

OSSB = (0.090 + 0.125) · tan 45° = 0.2150 in BA = 2 · 0.2150 − 0.2050 = 0.2250 in K = (0.2250 / 1.570796 − 0.090) / 0.125 = (0.14324 − 0.090) / 0.125 = 0.4259

0.426 rounds to the printed 0.43, so that row is self-consistent. When you check a chart this way and a row does not reproduce its own K, ask the shop which column its brake programs actually use before you load either one.

Worked example 3: what rounding does to a solved K

The Machinery's Handbook bending page works an example in soft steel, which takes its formula 33 (the Y = 0.64 group). For a 180° bend at 0.375 in radius in 0.125 in stock it gives L = 1.338 in, and for a 60° bend at 0.625 in radius it gives 0.707 in. PTC's Creo help lists that group as K 0.41 and gives the table formula L = (π/2 × R + Y × T)·Θ/90, which equals θ·(R + K·T) only when Y = K·π/2; 0.64 ÷ (π/2) is 0.4074. Feed the two printed lengths back through route 1:

180° bend: K = (1.338 / 3.141593 − 0.375) / 0.125 = 0.4072 60° bend: K = (0.707 / 1.047198 − 0.625) / 0.125 = 0.4011 60° bend with the unrounded 0.7075: K = 0.4049

The 180° case lands on the group value. The 60° case drifts by 0.006, and about 0.004 of that comes from rounding 0.7075 to three decimals. The reason is the sensitivity ∂K/∂BA = 1/(θ·T): a small angle and thin stock make K swing hard on tiny length errors. Here 1/(1.0472 × 0.125) is 7.6, so half a thousandth of an inch in L moves K by about 0.004. The remaining 0.0025 comes from the Handbook's use of 1.57 in place of π/2.

How accurate is your K?

Every reading that goes into the solve carries an error, and the calculator pushes each tolerance through the formula separately (half the change in K between the high and low reading), then reports both the worst case (all errors adding) and the root-sum-square (independent errors). The tolerances on the form are example values. Replace them with what your gauges can really resolve.

Which reading moves K the most in worked example 1 Horizontal bar chart of the change in K caused by each reading tolerance for the two-bend coupon. Angle plus or minus 0.5 degrees: 0.0149. Radius plus or minus 0.1 millimeter: 0.0137. Each of four length readings plus or minus 0.02 millimeter: 0.0127. Thickness plus or minus 0.02 millimeter: 0.0085. Worst case total 0.050, root-sum-square 0.025. angle ±0.5°±0.0149 radius ±0.1 mm±0.0137 4 lengths ±0.02 mm±0.0127 thickness ±0.02 mm±0.0085 bar length = change in K (scale: 0.015 = 300 px) worst case ±0.050 · root-sum-square ±0.025 → K ≈ 0.420 ± 0.025
Figure 2. Error budget for the coupon in worked example 1, using the form's default tolerances. The bent angle, read after springback, is the largest single term at these settings.

Two things in that chart surprise most people. First, the angle matters as much as the radius. At 90° the outside setback is (R + T)·tan(θ/2), and its slope with angle is steep, so half a degree of protractor error is worth more than a tenth of a millimeter of radius. Measure the angle on the formed part after it has sprung back, not the angle programmed into the brake. The Handbook makes the same point: the angle of bend is the angle through which the material has actually been bent, which is not always the angle on the drawing.

Second, the radius term is much smaller here than in route 1. When K is solved from a bend allowance, ∂K/∂R is −1/T, so a 0.1 mm radius error on 2 mm sheet shifts K by 0.05. In the test-piece route the same radius also sits inside the outside setback that converts BD to BA, which pulls the other way. The net slope is (2·tan(θ/2)/θ − 1)/T, about 0.27/T at 90°, and the error drops to roughly a quarter.

K and R travel as a pair

That partial cancellation has a practical consequence. Suppose the true radius is 2.2 mm but you typed 2.1 or 2.3. The coupon still yields a K, and that K paired with the radius you typed reproduces the 3.625 mm deduction at 90° exactly, because that is the condition it was solved from. The error only leaks out at other angles:

Radius typedSolved KBD at 90°BD at 45°BD at 135°
2.1 mm0.40633.62501.109112.9341
2.2 mm (true)0.41993.62501.091913.1169
2.3 mm0.43363.62501.074713.2997

So a K is only portable together with the radius it was solved against. If your CAD template models a different radius from the one used on the coupon, the flat pattern will be right at the test angle and off by a growing amount as the angle moves away from it, about 0.18 mm per bend at 135° in this sheet. Record K and R side by side, and test at the angle your parts mostly use.

More bends on the coupon, less length error

In route 3, a coupon with n bends needs n + 1 flange readings plus the blank, so n + 2 length readings feed one surplus that is then split n ways. If each reading carries ±δ, the deduction per bend carries up to ±δ·(n + 2)/n. A single-bend L coupon triples δ; a channel doubles it; four bends bring it to 1.5 δ.

Length-error multiplier against the number of bends on a test coupon Column chart of the factor (n plus 2) divided by n, which multiplies a single length-reading error to give the worst-case error in the measured bend deduction. One bend: 3.00. Two bends: 2.00. Three bends: 1.67. Four bends: 1.50. Six bends: 1.33. 0123 3.002.001.671.501.33 1 bend2 bends3 bends4 bends6 bends worst-case deduction error per bend = δ × (n + 2) / n
Figure 3. Why a multi-bend coupon is worth the extra forming. The gain flattens quickly; past three or four bends, the angle and radius readings dominate the budget.

Carrying K to other angles

The Handbook tabulates its formulas for 90° and tells you to multiply by the bend angle over 90 for anything else, and PTC's bend-table help applies the same θ/90 scaling. Both assume one K holds across angles for a given radius and thickness. The calculator follows that convention when it lists BA and BD at 30° to 135° from your solved K. Treat those rows as a starting point: if a part mixes sharp and shallow bends, form a coupon at each angle class and compare.

Mistakes that produce a wrong K

When this calculator is the right tool

You haveUseWhy
A formed coupon and its blankThis page, first tabThe measured route; K reflects your sheet, die and brake
A shop's deduction chartThis page, second tabConverts the chart into a K for a CAD template, and checks its columns agree
A K already, and a drawing to lay outBend allowance calculatorRuns the forward direction for flat-blank length across many flanges
No part yet, only a material nameA handbook group as a placeholderGood enough to quote; replace it once a coupon exists
From the tooling floor: scribe the die opening, the gauged radius and the solved K onto the coupon itself and keep it with the part's inspection records. When the job returns months later on a different brake, forming one new coupon and comparing it to the old one shows in minutes whether the flat pattern still holds.

Sources

Each source below was fetched on November 20, 2026. The calculator's own code was run against the published SkyCiv example, the Handbook 180° example and the SendCutSend 0.125 in 4130 row; the SkyCiv case returns K = 0.455, matching its page, and the other two are worked above.

  1. Machinery's Handbook, 31st ed., p. 1421: bending-allowance formulas 32–34, the soft-steel example (1.338 in and 0.707 in), angle of bend versus drawing angle, springback
  2. PTC Creo Help, About Bend Tables (three 90° tables: K 0.35, 0.41, 0.45 beside Y 0.55, 0.64, 0.71; formula L = (π/2 × R + Y × T)·Θ/90; θ/90 scaling)
  3. SkyCiv, K-Factor for Sheet Metal Calculator (K = 180·BA/(π·θ·T) − Ri/T; example T 2, Ri 1, 90°, BA 3 gives 0.455; usual band 0.3 to 0.5)
  4. Omni Calculator, K-Factor Calculator (K as the neutral-axis location over thickness, same rearranged formula)
  5. SendCutSend, Bending Calculator (K = t/MT, BA = π·(R + K·T)·A/180, BD = 2·OSSB − BA, per-material bend specification tables)
  6. Wikipedia, Bending (metalworking), Bend deduction (BD = 2·(R + T)·tan(A/2) − BA; BD as flange lengths to the apex minus flat length)

Reviewed by the JCH tooling team, November 20, 2026

Questions and answers

What does a K-factor of 0.42 actually mean?

It says the layer of metal that keeps its original length sits 42 percent of the way through the sheet, counted from the face on the inside of the bend. On 2 mm stock that layer is 0.84 mm deep. A value of 0.5 would put it dead center; real formed bends usually shift it inward, toward the compressed side.

Can I measure bend allowance directly with calipers?

No. Bend allowance is a curved length hidden within the thickness, so no jaw can reach it. Measure things that are straight and external instead: the strip before forming, and each flange across its outer surfaces afterward. Their difference, split per bend, is a deduction, and two setbacks convert that into the allowance.

Which input is the biggest source of error when solving K?

With this page's example tolerances (half a degree, a tenth of a millimeter on radius, two hundredths on each length) applied to a 90° coupon of 2 mm sheet, the final angle and the gauged radius contribute about equally, with caliper readings close behind and thickness smallest. Change the tolerance boxes to match your own instruments and the result panel ranks them for your case. Reading the angle after springback matters more than most people expect.

How many bends should a K-factor test coupon have?

Two or three is a good compromise. One bend leaves the blank and flange readings carrying their full error into a single deduction; a channel cuts that penalty by a third, and adding a third bend, such as a return lip on one leg, trims it a little further. Past four bends the coupon gets awkward to form and the gain is small.

My solved K differs from the default in my CAD template. Which one should I use?

Use the one solved from your own coupon, entered together with the radius you gauged on it. A template default is a generic starting value that knows nothing about your die width, sheet lot or brake. If the two disagree by a lot, form a second coupon before trusting either.

How do I convert a shop's deduction chart into a K-factor for CAD?

Take one row of the chart, enter its thickness, radius, angle and deduction on the second tab, and read off K. Repeat for each thickness you use, since a chart's K can differ from one thickness row to the next. Then confirm the chart's own K column, if it has one, matches what you computed.

Does one K-factor work for every bend angle?

The common handbook and CAD convention scales the allowance linearly with angle, which amounts to holding K constant. That is usually close enough for layout, but a radius typed wrong when K was solved causes errors that grow the further a bend sits from the coupon's angle. For parts dominated by shallow or very deep bends, form a coupon at that angle too.

Ask JCH about a K-factor that will not settle

Coupons disagreeing with each other, or a CAD flat pattern that misses by the same amount every time? Describe it to our site assistant. It knows the tools and guides here, and someone on our team can follow up on the conversation.

Replies come from software and may be wrong. They are not quotes and they bind no one.

Sorting out a flat pattern that keeps missing?

Send us the drawing and your coupon readings. Our team will look at the radius, angle convention and deduction behind the blank, and suggest a first-article check that settles which number is wrong. The figure above stays an engineering estimate until a part is measured.

Book a free 30-minute first consultation Send a drawing
JCH Design & Manufacturing — tooling, injection molding, PCBA, custom packaging, cut-and-sew & QC via vetted partner factories · Book a 30-minute call · jack@jchtrade.com · (321) 323-4474 · Canonical: https://jchtrade.com/tools/k-factor-calculator