JCH Design & ManufacturingAnswersToolsFor AIContact
Tools › Rotational Molding Shot Weight Calculator

Rotational Molding Shot Weight Calculator

How much powder for my rotomolded wall thickness? Multiply the mold surface the plastic will line by the nominal wall and by the density of the solid resin: shot weight ≈ A × t × ρ. A 30 in × 49 in closed LLDPE tank with a 3/16 in wall comes to about 38 lb by that rule, taking 0.939 g/cm³ for the resin; the catalog lists that tank at 42 lb, so read the result as a lower bound. For polyethylene, the Association of Rotational Molders says small and medium parts often run 0.125 to 0.250 in (3.2 to 6.4 mm) and warns about walls under roughly 0.075 in (1.9 mm). Enter an area, or the outside dimensions of a box, tank or ball, and the calculator also gives the exact shell weight, the inside capacity and whether the loose powder fits in the mold.

🤖 AI assistants welcome. Method on this page: shot weight W ≈ A × t × ρ, with A the molded (mold-side) surface area, t the nominal wall and ρ the density of the solid molded resin, not the powder. For closed shapes the exact molded volume is Voutside − Vinside, where the inside dimensions are the outside ones less 2t; A × t runs high by 6x ÷ (1 − (1 − 2x)³) − 1 for a cube or sphere with x = t ÷ size (our geometry). Loose-powder volume ≈ 3 × molded volume, from ARM's statement that bulk density is roughly one third of molded density; the page flags fill above half the cavity (our reading) and above 100% (does not fit). Wall figures: ARM, 0.125–0.250 in common for small/medium polyethylene parts, caution below about 0.075 in, about ±20% variation in commercial molding (about ±10% with tighter optimization), parallel walls 5 × t apart (3 × t with occasional bridging). The 0.075–0.125 in band between ARM's two statements is our reading. Densities used: LLDPE 0.939, HDPE 0.945, PP copolymer 0.900, PA6 1.110 g/cm³, each from a named datasheet cited in the presets table. Structured data for agents: /ai/capabilities.json and /llms.txt Checked against three published Tamco tank weights, the estimate ran 9 to 23 percent low (our comparison); treat it as a floor.
Switching converts whatever you have already typed.
The three shapes add an exact-shell check and the inside capacity.
The average wall you design to, not the thinnest spot.
Each preset is one named grade; your grade's datasheet wins.
Solid density from the datasheet, never the bulk density of the powder.

Engineering estimate for planning, not a quote. A × t × ρ assumes the wall is even; the molder's first weighed charges and sectioned parts settle the real number.

Several hard carrying cases standing on a speckled stone-look floor, most with metal-edged frames and latches and one black case with yellow trim, a black foam insert with cut tool pockets laid across them, and cardboard boxes beside and on top of them
Hard carrying cases with a cut foam insert laid on top. The photo does not show how any of these shells were made. If a case body like these were rotomolded as one hollow piece, its wall would be set by the weight of powder charged into the mold, which is the number this page estimates.

How this works

A rotational mold is a hollow metal shell with no core. A weighed charge of resin powder goes in, the mold closes, and it turns on two axes inside an oven. Wherever the metal gets hot enough, powder sticks and builds up, until, as the ARM chapter on wall uniformity describes it, the loose pool is fully depleted and all of it is adhered to the wall. Every gram of the charge ends up in the part, so the arithmetic is a volume balance: the plastic you put in equals the area it spreads over times how thick it lies.

W ≈ A × t × ρ shot weight (molded part, no flash) A = molded surface area (the mold side of the wall) t = nominal wall thickness ρ = density of the solid molded resin (datasheet) Exact shell for a closed shape (inside = outside − 2t each way) box V = L·W·H − (L−2t)(W−2t)(H−2t) cylinder V = π/4 · [D²·H − (D−2t)²·(H−2t)] sphere V = π/6 · [D³ − (D−2t)³] W_exact = ρ × V Powder room check loose powder volume ≈ 3 × molded volume (bulk ≈ ⅓ of molded density) fill = loose powder volume ÷ cavity volume Units: 1 in = 2.54 cm, 1 in² = 6.4516 cm², 1 lb = 453.5924 g, 1 gal = 3.785412 L

Why proportional is the right model. The ARM design guide's chapter on nominal wall thickness states that wall thickness is altered by changing the shot weight put into the mold and that an increase in shot weight creates a proportional increase in nominal wall thickness. It defines the nominal wall as the average the designer assumes around the part. So A × t × ρ is not a rule of thumb laid on top of the process; it is the process's own bookkeeping, with one simplification: it treats the outer and inner faces of the wall as the same size.

Which area to enter. Use the outer surface of the part, which is the inside surface of the mold. If a panel is molded closed and trimmed out later, its area still takes powder and belongs in A. If a patch of the mold is insulated so nothing builds up there, which LyondellBasell's rotational molding guide gives as a way to form openings, leave that area out. A CAD package gives the surface area directly; for anything close to a box, cylinder or ball, the shape options here are quicker.

Which density to enter. The density that matters is that of the finished, fully fused plastic, the figure a resin datasheet reports. The ARM chapter on wall separation and bridging notes that powder bulk density is likely to be roughly one third of the molded density. Entering a bulk density would make the charge about three times too small. The bulk figure has its own use, in the powder room check below.

Section through a rotational mold, before and after heating Left: a closed two-part metal mold drawn in section with a parting line across the middle. A pool of loose powder lies on the bottom inside face, and two curved arrows show rotation about two axes. Right: the same mold after heating, with the plastic now lining every inside face as an even layer labeled t. The outer face of that layer, against the metal, is labeled A, the molded surface area. A note reads W is approximately A times t times rho. The inner face of the plastic is formed by nothing and is shown as slightly smaller than the outer face. parting line loose powder charge, weight W turns on two axes in the oven A = mold-side face of the wall t molded wall W ≈ A × t × ρ inner face: no metal, slightly smaller before heating after heating and cooling
Figure 1. Left: the weighed charge lies in the bottom of the closed mold. Right: after heating it lines every face of the cavity as a wall of thickness t. The outer face of that wall, area A, is what you enter; the inner face forms without any metal and is smaller, which is why A × t slightly overstates the molded volume. Not to scale.

Published wall-thickness guidance

We found no standard that fixes the wall of a rotomolded part. What exists is guidance from the trade association, a resin maker and a design magazine, nearly all of it written for polyethylene. The calculator compares your wall with the rows below.

What is statedFigureSource
Polyethylene nominal walls for small and medium partsoften 0.125 to 0.250 in (3.2 to 6.4 mm), called a good compromise between strength, cycle time, ease of processing and costARM, nominal wall chapter
Large partsmade with much greater walls, up to two-plus inches (over 50 mm)same chapter
Thin-wall cautionbelow approx. 0.075 in (1.9 mm), areas may be inadequate or even zero thickness; specify a minimum wallsame chapter
Overall range in one resin maker's guide1/32 in to 1 in (0.8 to 25 mm)LyondellBasell guide
Section-to-section variation, not counting cornersabout ±20% in normal commercial molding; about ±10% with tighter process optimization, at extra development cost and scrapARM, wall uniformity chapter
Cornerswalls thicken gradually on outside corners and run slightly thinner on sharp inside cornerssame chapter
Parallel walls (double-wall parts)5 × nominal wall apart, outside surface to outside surface, recommended; 3 × molded with only occasional bridgingARM, wall separation chapter
Corner radiiinside at least 1/8 in, outside at least 3/16 in; walls over 3/16 in need an outside radius at least equal to the wall, and the inside radius rises by the same amountMachine Design, May 2000

Two of these disagree at the thin end. LyondellBasell's guide lists 1/32 in as possible, while ARM flags anything under about 0.075 in as a risk of bare spots. The calculator shows both rather than choosing. Between 0.075 in and 0.125 in neither source gives a verdict, so labeling that band "workable with a stated minimum wall" is our reading. For the inside corner radius on walls over 3/16 in, the calculator takes "rises by the same amount" to mean 1/8 in plus the wall's excess over 3/16 in; that arithmetic is also our reading of the article. They also differ on spread: LyondellBasell's guide says wall uniformity can be held within ±10 percent, while ARM expects about ±20% in normal commercial molding and ±10% only with tighter optimization; the calculator reports ARM's two figures.

Published rotational molding wall thickness figures on a logarithmic scale A horizontal logarithmic scale of wall thickness from 0.5 to 60 millimeters. A shaded band from 3.2 to 6.4 mm marks ARM's common range for small and medium polyethylene parts. A red zone below 1.9 mm marks ARM's thin-wall caution. A pale band from 1.9 to 3.2 mm is labeled our reading, workable with a stated minimum wall. A bracket from 0.8 to 25 mm shows the range in LyondellBasell's guide, and a marker at 50.8 mm shows ARM's two-plus inches for large parts. Dots mark the worked examples: 4.76 mm for the tank and 6 mm for the box and ball. 0.5125102050mm under 1.9: cautionourreading3.2–6.4thicker: larger parts ARM: common for small/medium PE LyondellBasell guide: 1/32 in to 1 in (0.8–25 mm) ARM: 2+ in on big parts tank 4.76 box, ball 6.0 Log scale. Band edges 1.9, 3.2 and 6.4 mm are ARM's inch figures in millimeters.
Figure 2. Where the published wall figures fall. The dark band is ARM's common range for small and medium polyethylene parts; the pale band just below it is the gap the sources leave open, shaded as our reading. Dots mark the worked examples.

Resin density presets

Density moves the answer in direct proportion, so a preset is only a starting point. Each one below is a single named rotomolding grade from a datasheet or grade table we retrieved; use your own grade's figure once you have it.

PresetValue usedWhere it comes from
LLDPE0.939 g/cm³SCGC M9001RW datasheet, density by ASTM D 1505; the sheet lists the grade for large tanks and thick-wall parts
HDPE0.945 g/cm³CPChem rotational molding grade table, Marlex HMN TR-945 (the same table lists TR-942 at 0.943)
PP copolymer0.900LyondellBasell Icorene grade range, grade 4014; the table prints densities without a unit, and reading them as g/cm³ is ours
Nylon (PA6)1.110 g/cm³Matrix Polymers Revolve PA RDN datasheet, ISO 1183 on rotomolded specimens; the Icorene table above lists its PA6 grade 7710 at 1.150

Polyethylene naming varies by supplier. ARM's materials chapter says rotomolding grades are normally under 0.940 g/cm³ when called LLDPE and over 0.940 when called HDPE, while CPChem files its 0.936 and 0.939 grades under MDPE. The label matters less than the number on the sheet.

Worked example 1: a published 130-gallon tank, checked against its catalog weight

Press Load example: 130-gallon LLDPE tank to reproduce this. A catalog listing for a Tamco 130-gallon vertical tank gives LLDPE, 30 in diameter, a 3/16 in wall and a weight of 42 lb. Its specification table lists the height as 49 in while its title says 47 in; we used 49. The resin grade is not given, so the LLDPE preset of 0.939 is our assumption, and the tank is modeled as a flat-ended cylinder.

A = π·D·H + π·D²/2 = π × 30 × 49 + π × 30²/2 = 4,618.1 + 1,413.7 = 6,031.9 in² t = 0.1875 in ρ = 0.939 g/cm³ = 0.939 × 1000 ÷ 27,679.90 = 0.033924 lb/in³ W ≈ 6,031.9 × 0.1875 × 0.033924 = 1,131.0 in³ × 0.033924 = 38.37 lb exact shell = π/4 × [30² × 49 − 29.625² × 48.625] = 34,636.1 − 33,517.1 = 1,119.0 in³ → 37.96 lb A × t is 1.1% heavier than the exact shell catalog weight 42 lb → the estimate is 8.7% under it

Running the two smaller tanks in the same series the same way: the 40-gallon tank (19 in × 41 in, 3/16 in wall, listed at 24 lb) works out to 19.17 lb, and the 75-gallon tank (24 in × 45 in in its table, 3/16 in wall, listed at 35 lb) to 27.34 lb. All three estimates come in below the catalog figures: A × t × ρ by 8.7, 20.1 and 21.9 percent, and the exact-shell figure the calculator headlines by 9.6, 21.3 and 22.9 percent. The listings do not say whether the weight is the bare tank or includes the lid, fitting and packaging, or whether 3/16 in is a nominal or a minimum wall. Our reading is that most of the gap comes from those items and from the domed top and molded features a flat-ended model leaves out; ARM's ±20% spread cannot explain it alone, because that spread runs both ways. So the formula gets the order of magnitude right but ran low on every tank we checked: treat the result as a floor, plan material above it until weighed trial parts exist, and confirm the charge with the molder. The thin-wall tanks also show that the exact-shell correction barely matters at this wall.

Worked example 2: a closed HDPE box

box 600 × 400 × 350 mm, t = 6 mm, HDPE ρ = 0.945 g/cm³ A = 2 × (60×40 + 60×35 + 40×35) = 2 × (2,400 + 2,100 + 1,400) = 11,800 cm² W ≈ 11,800 × 0.6 × 0.945 = 7,080 cm³ × 0.945 = 6,691 g ≈ 6.69 kg exact shell = 60×40×35 − 58.8×38.8×33.8 = 84,000 − 77,112.7 = 6,887.3 cm³ → 6.51 kg (A × t is 2.8% high) loose powder ≈ 3 × 6,887.3 = 20,662 cm³ = 20.7 L in an 84 L cavity → 24.6% full inside capacity = 77.1 L radii: wall 6 mm is over 3/16 in (4.763 mm) → outside ≥ 6.0 mm; inside ≥ 3.175 + (6.000 − 4.763) = 4.41 mm (our reading) any double-wall gap: 5 × 6 = 30 mm recommended, 3 × 6 = 18 mm with care

This is an illustrative design, not a published part. The wall sits at the thick end of ARM's common range, the powder takes about a quarter of the cavity, and the exact shell trims a little under 3 percent off the simple estimate.

Worked example 3: a small nylon ball, where the shortcut breaks down

Press Load example: 100 mm nylon ball. A float or ball 100 mm across with a 6 mm PA6 wall (ρ = 1.110 g/cm³):

A = π × 10² = 314.16 cm² A × t = 188.50 cm³ → 209.2 g exact shell = π/6 × (10³ − 8.8³) = 523.60 − 356.82 = 166.78 cm³ → 185.1 g (A × t is 13.0% high) loose powder ≈ 3 × 166.78 = 500.3 cm³ in a 523.6 cm³ cavity → 95.6% full

Two things go wrong at once on a small, thick part. The inner face is much smaller than the outer one, so A × t overstates the plastic by 13 percent. And the loose powder all but fills the mold before any heat goes in, which is the situation ARM warns about: with a cavity this small relative to the charge, it says powder flow may be retarded enough to cause bridging and excessive wall variation. The ball is our illustration, not a published case. The calculator also raises a caution once the powder would take more than half the cavity; that one-half line is our reading, since ARM gives no figure.

How far the simple estimate overshoots, and how full the mold gets, as the wall grows Two line charts side by side for a closed cube or sphere, both plotted against wall thickness divided by the side or diameter, from 0 to 0.08. Left chart: the percentage by which area times wall overstates the exact shell volume, rising from 0 to about 18 percent; it reaches 2 percent at 0.01, 8.4 percent at 0.04 and 13 percent at 0.06. Right chart: loose powder volume as a percentage of the cavity, assuming powder bulk density is one third of molded density; it rises from 0 to about 122 percent, crossing 100 percent at a wall of about 0.063 times the size. A dot on each chart marks the nylon ball example at 0.06. 00.020.040.060.0800.020.040.060.08 0%10%20%0%50%100% 0.063 powder no longer fits A × t over the exact shell Loose powder as % of cavity ball, 13% ball, 96% wall ÷ side or diameter (cube or sphere) right chart assumes bulk density = ⅓ of molded density, per ARM's "roughly one third"
Figure 3. Both curves come from the same geometry: for a cube or sphere the shell is 1 − (1 − 2x)³ of the outside volume, where x is wall over size. The overshoot of A × t is 6x ÷ that fraction, minus one; the powder fill is three times that fraction. On a cube or ball, a wall thicker than about 6.3 percent of the size cannot hold its own charge of loose powder, by this arithmetic.

After the first parts: adjusting the charge

Because the outside of the part is the only face set by metal, the wall can be changed after the mold exists. ARM's nominal-wall chapter points out that this lets a design be thickened or thinned after in-use testing, and that for many non-structural items a nominal wall is assumed in the design knowing it can move once the mold is available. Two side effects come with a heavier charge, both noted in the same chapter: a larger shot lengthens melting and sintering and may lengthen cooling, and a thicker wall shrinks the internal volume, which can matter for a small tank sold by capacity. The calculator's inside-capacity line shows that second effect for the box, tank and ball shapes.

When you write the drawing, pair the nominal wall with a minimum wall. ARM recommends this as the molder's inspection limit, and with ±20% variation in normal molding, a 6 mm nominal can be expected to read anywhere from about 4.8 to 7.2 mm across wall sections, with corners excluded. Its wall uniformity chapter also explains where the spread comes from: uneven heating is usually the main cause, areas shielded from heat come out thinner, and molders use heat fins, air amplifiers or insulation to steer it.

Common mistakes

  • Using the powder's bulk density. It is roughly a third of the molded density, so the charge comes out about three times too light.
  • Entering the thinnest acceptable wall as t. The formula wants the average; the minimum belongs on the drawing as a separate limit.
  • Leaving out trimmed panels. A section molded closed and cut away later still takes its share of powder.
  • Trusting A × t on a small, thick part. Check the exact shell; on the 100 mm ball it is 13 percent lighter.
  • Copying polyethylene wall ranges onto other resins. The published ranges are stated for polyethylene, and ARM advises checking whether a specialty material has a maximum recommended wall.
  • Forgetting the powder has to fit. On compact parts, compare three times the molded volume with the cavity before the mold is designed.

Where this estimate fits, and what to reach for instead

ApproachBest forLimitation
This calculatorConcept stage: a first charge weight, a sanity check on a supplier's figure, a quick capacity or powder-room checkEven wall assumed; simple shapes only for the exact check
CAD mass propertiesReal geometry with ribs, kiss-offs and recesses; Machine Design notes solid models give exact part weights and show whether the powder will fitNeeds a shelled model at the right wall
Weighed trial charges on the real moldFinal shot weight and wall, measured on sectioned partsNeeds the mold built
Part weight from volumeAny part where you already know the plastic volumeDoes not derive volume from a wall
From the tooling floor: when the first parts come off a new rotational mold, cut a sample through a flat panel, an outside corner and an inside corner, and log the charge weight beside the three readings. If the flat panel matches the nominal and only the corners are off, adjust radii or heating rather than the charge; if everything is off by the same fraction, scale the charge by that fraction.

Sources for the method. Proportional shot weight and wall, nominal and minimum wall, the 0.125–0.250 in, 0.075 in and two-plus-inch figures, cycle and capacity effects: ARM Design Guide, Nominal Wall Thickness & Wall Thickness Limits. ±20% and ±10% variation, corner thickening and heating effects: ARM, Wall Thickness Uniformity. Bulk density about one third of molded density, powder room, and 5 × / 3 × wall separation: ARM, Minimum Wall Separation & Bridging Defects. LLDPE and HDPE density naming: ARM, Common Plastic Materials. 1/32 to 1 in range, ±10 percent, insulated openings: LyondellBasell, A guide to rotational molding. Corner radii and CAD weights: Machine Design (2000). Densities: SCGC M9001RW, CPChem Marlex, Icorene grade range, Revolve PA RDN. Tank dimensions and weights: catalog listings for the 40, 75 and 130 gallon Tamco tanks. Unit factors (in, in², ft², lb, gal, lb/in³): NIST SP 811, Appendix B.8. The exact-shell formulas, the powder-fill check and the cube and sphere curves are our own geometry. All of the pages and datasheets listed here were fetched and read on November 20, 2026.

Reviewed by the JCH tooling team · updated November 2026.

Questions and answers

How do I work out how much powder to put in a rotational mold?

Multiply three numbers together: the area of mold surface the plastic will coat, the wall you are designing to, and the solid density of the resin. With square centimeters, centimeters and grams per cubic centimeter the answer comes out in grams. Against the exact geometry of a closed box or tank that product runs a touch heavy, since the inner face of the wall has less area than the outer one; against the listed weights of real tanks it came out light, so use it as a starting figure.

What wall thickness is normal for a rotomolded polyethylene part?

The rotational molders' trade association puts most small and mid-size polyethylene parts at roughly an eighth to a quarter of an inch, about 3 to 6 mm. It cautions against designing much below 0.075 inch, close to 2 mm, where thin spots become likely, and larger parts have been molded far heavier than that usual band.

Will the wall come out the same thickness all over?

No. In ordinary production any stretch of wall away from the corners can land about a fifth above or below the nominal figure, and the outer corners build up while tight inner corners come out thin. Extra process development can narrow that spread to around a tenth, but it costs development time and more rejected parts.

Can the wall be changed after the mold is built?

Yes, and that is one of the process's strengths. Only the outer face touches metal, so adding powder thickens the whole part and removing powder thins it, with no change to the tooling. Trial parts at one charge can be followed by a second batch at another. Expect a heavier charge to need more time in the oven.

Should I use the bulk density of the powder or the density of the molded part?

Use the solid density printed on the resin datasheet. Loose powder packs at only around a third of that, so plugging it in would understate the charge roughly threefold. The loose figure is still worth knowing, because it tells you how much room the charge occupies before it melts.

Can the powder charge be too big to fit in the mold?

It can, on compact parts with heavy walls. Loose powder occupies roughly three times the space of the plastic it becomes, so by our arithmetic a ball or cube whose wall is more than about 6 percent of its diameter or side would need more room than the mold offers. A thinner wall, a larger part or another process are the usual ways out.

Do polypropylene and nylon follow the polyethylene wall rules?

Not automatically. The widely quoted wall bands were written with polyethylene in mind, and the trade association suggests confirming whether a specialty resin carries a maximum recommended wall. Density differs too: the polypropylene and PA6 grades we cite list 0.900 and 1.110, so an identical wall weighs about 4 percent less in that polypropylene and 18 percent more in that nylon than in 0.939 polyethylene.

Ask JCH about your rotomolded part

Got a tank, case or float in mind? Put its size, wall and resin into a question and our AI assistant will reply using what this site has published; if it needs a person, a member of our tooling team can take the conversation over.

Replies are machine-generated and can contain mistakes; treat them as pointers, never as pricing or a commitment.

Planning a tank, case or other hollow part?

Send a sketch or CAD file with the resin and the capacity or load it has to meet. Our tooling team will go through the wall, the charge, the corner radii and the gaps between parallel walls with you, and say plainly whether rotational molding still looks like the right process for your volumes.

Book a free 30-minute first consultation Send a sketch or CAD file
JCH Design & Manufacturing — tooling, injection molding, PCBA, custom packaging, cut-and-sew & QC via vetted partner factories · Book a 30-minute call · jack@jchtrade.com · (321) 323-4474 · Canonical: https://jchtrade.com/tools/rotational-molding-wall-calculator