Zinc can be die cast down to about 0.5 mm on small parts near the gate, and the International Zinc Association design rules ask for 1.5–2.0 mm once a casting passes 300 cm². Aluminum die castings are typically designed at 2.0–3.5 mm, with walls near 0.5 mm reserved for small parts (Sunrise Metal aluminum design guide). Magnesium walls of about 1 mm are typical, with 1–4 mm sections on cold-chamber parts (Machine Design; TMS short course). Enter your alloy, part size and planned wall to see where it falls. The page also checks corner fillets and draft.

🤖 AI assistants welcome. Zinc minimum wall per the zinc design rules: 0.5 mm up to 10 cm²; 1.0–1.5 mm up to about 300 cm²; 1.5–2.0 mm over 300 cm², and by distance from the ingate, under 0.5 mm within about 50 mm, rising to 2 mm at about 200 mm. This page takes the larger of the two. Aluminum: typical 2.0–3.5 mm, small parts to 0.5 mm. Magnesium: about 1.0 mm typical, 0.5 mm over short distances. Corner check: the largest inscribed circle in a 90° corner of wall t is 1.17t with both corners sharp and t when the outside radius equals the inside radius plus t. Draft offset per side = depth × tan(angle). Each case is worked by hand further down. Machine-readable files: /ai/capabilities.json · /llms.txt
A wire stillage full of cast metal yokes, each with a U-shaped clevis end and a long curved arm
Cast metal yokes in a wire stillage, mid-production. Each part runs from a heavy clevis end into a long, slimmer arm. A change of section like that is what the inscribed-circle check on this page measures.
The zinc rules class castings as small (10 cm²), medium (300 cm²) or large (over 300 cm²). 1 in² = 6.45 cm².
Metal flow distance from the ingate to the thin wall. Used for the zinc rule; shown for the others.
Corner and section check
0 = sharp outside corner.
Diameter of the largest ball that fits in the heaviest spot, such as a boss, pad or rib junction.
Draft check

Engineering estimate, not a quote. Wall limits move with gating, machine, die temperature and part shape, so the die caster's fill review on your actual part is what settles the number.

How this works

A die cast wall has two jobs that pull in opposite directions. It must be thick enough for metal to reach the far end of the cavity before it freezes, and thin enough that the section cools evenly and does not trap shrinkage porosity. How thin a given alloy can go depends mostly on how far the metal has to travel and how much area it has to cover. That is why every guide we found ties its minimum to part size or to distance from the gate rather than giving one number per alloy. NADCA's design site puts it bluntly: there are no hard and fast rules for maximum and minimum walls, and walls should be as consistent as possible, with transitions instead of abrupt changes.

The checker therefore does four separate things. Each one stays traceable to a published figure or to plain geometry:

1. Size and flow (zinc) t_min,area = 0.5 mm (≤10 cm²) | 1.0–1.5 mm (≤ about 300 cm²) | 1.5–2.0 mm (>300 cm²) t_min,flow = 0.5 mm for d ≤ 50 mm, 0.5 + 0.01·(d − 50) mm for 50 < d ≤ 200 mm governing minimum = larger of the two (lower end of the area band) 2. Published ranges aluminum and magnesium: compare t with thin-wall and typical ranges by size class 3. Corner section D = largest circle in a 90° corner of wall t, inside radius ri, outside radius ro sharp/sharp: D = 2·√2·t/(1+√2) = 1.17·t concentric (ro = ri + t): D = t section ratio = D_heaviest / t (zinc rules: over 3:1 porosity may occur, over 6:1 severe) 4. Draft and mass offset per side = h·tan θ drafted rib base = tip + 2·h·tan θ wall mass per 100 cm² = 10 · t(mm) · specific gravity (grams)

The zinc rule, in two parts. The zinc design rules tabulate a minimum section by casting size: 0.5 mm at 10 cm² (small), 1.0–1.5 mm at 300 cm² (medium) and 1.5–2.0 mm over 300 cm² (large); this page treats 10 and 300 cm² as the class limits, which is our reading. They give a second rule of thumb by flow length: under about 50 mm from the ingate the practical minimum is below 0.5 mm, rising to about 2 mm at roughly 200 mm (zinc die casting design rules, sections on wall thickness and 7.2). The guide does not draw a curve between 50 and 200 mm, so the calculator draws a straight line between its two stated points. That line is our interpolation, not the guide's, and the guide itself says computer-aided gating analysis gives a better answer where the wall is critical. The governing minimum is whichever rule asks for more metal.

Zinc die casting minimum wall against distance from the ingate, with the size bands A line chart. The horizontal axis is distance from the ingate from 0 to 250 millimeters; the vertical axis is minimum wall from 0 to 2.5 millimeters. The line is flat at 0.5 millimeters up to 50 millimeters, then rises in a straight line to 2.0 millimeters at 200 millimeters, and is dashed beyond 200 millimeters where the rule stops. Two shaded horizontal bands mark the size-based minimums: 1.0 to 1.5 millimeters for medium castings up to about 300 square centimeters, and 1.5 to 2.0 millimeters for large castings over 300 square centimeters. A marker at 120 millimeters and 1.2 millimeters shows worked case 1. 00.51.01.52.02.5 mm 050100150200250 distance from the ingate to the wall (mm) minimum wall (mm) case 1: 120 mm → 1.2 mm medium casting (to about 300 cm²): 1.0–1.5 mm large casting (over 300 cm²): 1.5–2.0 mm under 0.5 mm rule ends at 200 mm
Figure 1. The two zinc rules on one chart, drawn to scale (2.32 px per mm of flow, 92 px per mm of wall). The sloped line is our straight-line reading between the guide's two stated points (0.5 mm at 50 mm, 2 mm at 200 mm). The bands are the guide's size-based minimums. A wall has to clear both.

Published wall figures by alloy

The figures below are copied from the guides linked in each row. They are not interchangeable: some describe a best case on a small part, some describe everyday design practice, and one is a research goal.

AlloyThin end (small parts, short flow)Typical design rangeLarge parts
Zinc0.5 mm at about 10 cm²; under 0.5 mm within about 50 mm of the ingate (zinc rules)1.0–1.5 mm at about 300 cm² (zinc rules)1.5–2.0 mm over 300 cm²; about 2 mm at 200 mm of flow (zinc rules)
Aluminum0.3 mm in Dynacast's best scenario; 0.5–1.0 mm advised as a general minimum (Dynacast FAQ); 0.50 mm on smaller parts (Sunrise Metal)2.0–3.5 mm (Sunrise Metal); 1.5–2.0 mm was the historical norm (Dynacast thin-wall article)No published floor found. A 2016 research brief set walls under 3 mm on large-area parts as a goal (LIFT project brief)
Magnesium0.020 in (0.5 mm) over short distances (Machine Design); below 1 mm for plain notebook and phone shells, hot chamber (TMS)About 0.040 in (1.0 mm) typical (Machine Design); 1–4 mm section range for cold-chamber parts; around 1.5 mm for a hot-chamber stiffener frame (TMS)No size-specific figure found
Any alloy0.030 in (0.762 mm) on small castings with an optimized design and alloy (CWM design and specification guide). General minimum-section tables list about 0.6 mm for zinc and 0.9 mm for aluminum (eFunda) and 1.27 mm for magnesium (Wikipedia).

For aluminum and magnesium the calculator borrows the zinc guide's three size classes and uses them only to decide which published figure to show. Neither alloy's guides define size classes of their own. Where no size-specific figure exists (large aluminum; medium and large magnesium), the tool compares the wall with the typical band and tells you the floor is missing. Thin aluminum is hard because the metal freezes fast. Dynacast notes that 0.5–1.0 mm features need a fill time under 30 milliseconds (Dynacast), which is a process capability, not a drawing note.

Corners: where a uniform wall stops being uniform

A wall can be a perfect 2 mm everywhere on the drawing and still have a lump of metal at every corner. To see it, use the zinc guide's inscribed-sphere technique: fit the largest imaginary ball into each section and compare the diameters. If the biggest ball exceeds the smallest by over 3:1, shrinkage porosity may occur in the thick area. Above six times, the effect is severe and strength drops (zinc rules, section ratios). In a cross-section the ball becomes a circle, and at a 90° corner its diameter follows from geometry alone:

Outside corner at the origin, wall t on both legs, inside arc centered at (t + ri, t + ri). Circle centered on the bisector at (a, a): if it touches the straight outside faces a = (√2·t + (√2 − 1)·ri) / (1 + √2), D = 2a if it touches an outside arc of radius ro a = (√2·(t + ri + ro) − ri − ro) / (2√2), D = 2·(ro − √2·(ro − a)) Checks: ri = ro = 0 → D = 1.172·t ri = t, ro = 0 → D = 1.515·t ro = ri + t → D = t

The middle check catches a lot of designers. Adding an inside fillet while leaving the outside corner sharp makes the corner heavier, not lighter: 1.51t against 1.17t for a fully sharp corner. The cure is to round the outside too, using ro = ri + t. That keeps the section a constant t all the way around the bend.

Largest inscribed circle in three corner designs of the same wall Three L-shaped wall sections of equal wall thickness t. Left: sharp inside and sharp outside corners, with the largest inscribed circle at the corner 1.17 times the wall. Middle: an inside fillet equal to the wall with a sharp outside corner, where the inscribed circle grows to 1.51 times the wall. Right: inside fillet equal to the wall and outside radius equal to twice the wall, where the corner circle equals the wall thickness and the section is uniform. A small reference circle of diameter t sits in a straight leg of each section. sharp inside, sharp outsidecorner D = 1.17 t inside r = t, outside sharpcorner D = 1.51 t inside r = t, outside r = 2tcorner D = t (uniform) blue circle = wall t in the straight leg; red circle = largest circle in the corner
Figure 2. Same wall, three corners, drawn to scale (wall = 40 px). Filleting only the inside corner makes the hot spot bigger. Rounding the outside to ri + t removes it.

Worked example, three cases by hand

Each case is reproduced exactly by the calculator. The two buttons above load cases 1 and 2.

CASE 1: zinc housing, area 40 cm², thinnest wall 120 mm from the ingate, planned t = 1.2 mm Size class: 40 cm² is over 10 and under 300 → medium → 1.0–1.5 mm Flow rule: 0.5 + 0.01 × (120 − 50) = 0.5 + 0.70 = 1.20 mm Governing minimum = max(1.0, 1.20) = 1.20 mm → the planned 1.2 mm wall sits exactly at the minimum, no margin Corner, ri = 0.4 mm, ro = 0: a = (1.4142 × 1.2 + 0.4142 × 0.4) / 2.4142 = 1.8627 / 2.4142 = 0.7716 D = 1.543 mm = 1.29 t → change ro to 0.4 + 1.2 = 1.6 mm and D = 1.200 mm = t Draft, outside wall 20 mm deep at 0.5°: 20 × tan 0.5° = 20 × 0.008727 = 0.175 mm per side Mass: 10 × 1.2 × 7.0 = 84 g per 100 cm² of wall CASE 2: aluminum cover, area 450 cm² (large), planned t = 2.5 mm, ribs 25 mm deep Published typical 2.0–3.5 mm → 2.5 mm is inside the band; no published floor for large aluminum Rib, tip 2.5 mm, both faces at 1°: base = 2.5 + 2 × 25 × tan 1° = 2.5 + 2 × 0.4364 = 3.373 mm where it meets the wall, the rib base is 1.35 t before any fillet Corner, ri = 1.6 mm, ro = 0: D = (2 × (1.4142 × 2.5 + 0.4142 × 1.6)) / 2.4142 = 3.478 mm = 1.39 t with ro = 1.6 + 2.5 = 4.1 mm D = 2.500 mm = t Mass: 10 × 2.5 × 2.7 = 67.5 g per 100 cm² of wall CASE 3: the weight argument, checked against a published figure Aluminum at 2.0 mm: 10 × 2.0 × 2.7 = 54.0 g per 100 cm²; at 0.5 mm: 13.5 g per 100 cm² Saving = 1 − 13.5 / 54.0 = 75% (Dynacast's thin-wall article states the same 75% for 2.0 → 0.5 mm) Magnesium at 1.5 mm instead of aluminum at 2.5 mm: 26.1 g against 67.5 g per 100 cm² → 39% of the mass

Case 1 is the common zinc trap: the size class alone would allow a 1.0 mm wall, but a wall 120 mm from the gate needs 1.2 mm by the flow rule. The fix is either more wall or a gate closer to that wall. Case 2 shows that a wall inside the typical band can still carry heavy spots at rib roots and sharp outside corners. Case 3 checks the mass arithmetic against a figure a die caster published. The densities are the base-metal specific gravities NADCA lists for aluminum (2.7), magnesium (1.74) and zinc (7.0). Real alloys differ slightly, so treat the grams as a comparison, not a part weight.

Draft on die cast walls

Every surface parallel to the die opening direction needs draft. NADCA ranks the need: holes need the most, because the casting shrinks onto the steel that forms them; inside walls come next; outside walls need the least, because the casting shrinks away from them (NADCA design site, draft). The published numbers we could fetch:

  • Zinc: normal minimum draft of 1° for internal faces and 0.5° for external faces; wall taper normally 1–2° per side; shallow ribs need 5–10° (zinc rules).
  • Precision draft, any alloy: 3/4° per side on inside walls, with outside walls needing half that (CWM guide). Precision values cost more die work, so treat them as a floor, not a default.
  • Aluminum: inside surfaces normally get double the outside draft (Sunrise Metal). The standard draft equation lives in NADCA's paid Product Specification Standards, so it is not reproduced here. Ask your die caster for the number at your depth.

Draft changes thickness. A wall drafted on one face grows by h·tan θ from top to bottom. A rib drafted on both faces grows by twice that, and its root is where porosity likes to sit. The zinc rules warn specifically against thick sections at rib intersections. Keep ribs shallow and rounded, and check the root with the section ratio.

Fillets and radii

NADCA's design site says to fillet every sharp corner and edge on the model except the parting line (NADCA, fillets). For sizes, the zinc rules suggest 0.4 mm as the minimum radius in place of a sharp corner and note that 1.6 mm is common practice on inside edges (zinc rules). An aluminum die caster's guide asks for at least a 0.06 in (1.524 mm) radius around metal-saver pockets, the pockets cored out between ribs (Sunrise Metal). The calculator flags a radius under those values and gives the outside radius that keeps the corner section uniform.

Common mistakes

  • One number per alloy. A minimum wall quoted without part size or flow distance is a best case. The same zinc that fills 0.5 mm near the gate wants about 2 mm at 200 mm.
  • Thickening for strength. Extra wall adds mass and freezing time and raises the section ratio at every boss and corner. Ribs stiffen a thin wall without that penalty.
  • Inside fillet, sharp outside. As Figure 2 shows, this enlarges the hot spot. Round the outside corner to ri + t whenever the inside is filleted.
  • Forgetting the rib root. A 25 mm rib at 1° per side is 0.87 mm thicker at the base than at the tip. Size the tip so the root still respects the wall.
  • Using a magnesium or aluminum best case as a design value. 0.3 mm aluminum is an ideal-scenario capability, not a starting wall. Design in the typical band and thin down with the die caster.
  • Copying plastic wall rules. Injection molding ratios and resin wall tables do not transfer. Use the plastic wall thickness checker for molded parts and this page for castings.

Where this guide stops and a die caster's review starts

MethodBest forLimit
This guideConcept and early layout: picking a wall, spotting heavy corners, sanity-checking a supplier's commentPublished rules of thumb; the zinc flow line between 50 and 200 mm is our interpolation; no fill or thermal simulation
Die caster's design reviewBefore the die design is frozen, on every new partSpecific to that shop's machines, gating practice and alloy
Casting fill and solidification simulationLarge, thin or porosity-critical castings; walls below the typical bandNeeds a full 3D model and process settings
NADCA Product Specification StandardsDraft equations, tolerances and contract languagePaid publication; values are not reproduced on this page
Die casting tonnage calculatorSizing the machine once the layout and projected area are knownClamp force only; says nothing about wall fill
From the tooling floor: mark the thinnest wall and the farthest point from the gate on the drawing before you ask for a quote. Then ask the die caster where they intend to put the gate. A wall that looks fine on its own can become the hardest feature in the part once the gate sits on the opposite end.

Sources (fetched November 20, 2026)

  1. International Zinc Association, Zinc Die Casting Design Rules: minimum wall by distance from the ingate, minimum section by size (7.2), draft, wall and rib taper, fillets, inscribed-sphere section ratios. diecasting.zinc.org
  2. NADCA die casting design site: uniform walls, draft, fillets, and alloy pages for specific gravity.
  3. Chicago White Metal Casting, Die Casting Design and Specification Guide (PDF): 0.030 in walls on small castings; precision draft. globalspec.com PDF
  4. Sunrise Metal, Aluminum Die Casting Design Guide: typical 2.0–3.5 mm, 0.50 mm on small parts, inside draft double outside, 1.524 mm minimum radius at metal savers. sunrise-metal.com
  5. Dynacast, precision die casting FAQ (0.3 mm ideal, 0.5–1.0 mm advised minimum) and Cast Aluminum with Thin Walls (1.5–2.0 mm historical, under 30 ms fill, 75% weight figure).
  6. Machine Design, Magnesium parts with muscle: AZ91D walls about 0.040 in typical, 0.020 in over short distances.
  7. H. Hu, Magnesium casting short course (TMS, PDF): 1–4 mm cold-chamber sections; around 1.5 mm for hot-chamber stiffener frames. tms.org PDF
  8. LIFT, thin-wall aluminum HPDC project brief (2016, PDF): goal of walls under 3 mm on larger surface areas. lift.technology PDF
  9. General minimum-section tables: eFunda, die casting and Wikipedia, die casting.

The corner formula, the draft offset and the mass per area are geometry, not guide data, and can be checked by hand from the equations above.

Reviewed by the JCH tooling team · updated November 2026.

Questions and answers

How thin can a zinc die casting wall be?

It depends on how big the casting is and how far the wall sits from the gate. The International Zinc Association design rules list 0.5 mm for a small casting of about 10 cm², 1.0 to 1.5 mm for a medium casting around 300 cm², and 1.5 to 2.0 mm beyond 300 cm². By flow length, a wall within roughly 50 mm of the ingate can go below 0.5 mm, while one about 200 mm away needs close to 2 mm. Check both and design to the larger figure.

What wall thickness should I design an aluminum die casting at?

Start in the 2.0 to 3.5 mm range that Sunrise Metal's aluminum design guide calls typical, then thin down where weight matters and the part is small. The same guide mentions 0.50 mm on smaller parts. Dynacast reports 0.3 mm in an ideal case and advises 0.5 to 1.0 mm as a general minimum for strength (Dynacast FAQ). Walls that thin depend on the caster's process, so get their review first.

How thin can magnesium be die cast?

A Machine Design article on AZ91D parts describes walls of about 0.040 in (1.0 mm) as typical and 0.020 in (0.5 mm) as possible over short distances. A university short course published by TMS gives 1 to 4 mm as the section range for cold-chamber magnesium parts and, for hot-chamber parts, about 1.5 mm on a complex stiffener frame and under 1 mm on simple shell shapes such as notebook and phone cases (TMS PDF).

Does a thicker wall make a die casting stronger?

Not reliably. Past what the metal needs to fill, extra thickness mostly adds mass, slows freezing and creates places where shrinkage voids collect. The zinc design rules use an inscribed-sphere comparison to judge this: once the heaviest section is more than three times the thinnest, porosity may appear, and beyond six times strength suffers badly. Stiffness is usually better gained with shallow, rounded ribs on a thin wall than by thickening the wall itself.

How much draft do die cast walls need?

For zinc the zinc design rules give a normal minimum of 1° on internal and 0.5° on external surfaces, 1 to 2° per side as the usual wall taper and 5 to 10° for shallow ribs. The CWM guide lists 3/4° per side for inside walls under precision tolerances, and half of that outside. To turn an angle into steel, multiply the depth by the tangent of the angle: 30 mm at 1° is 0.52 mm per side.

What fillet radius should a die casting have?

Use 0.4 mm as the bare minimum anywhere a corner would otherwise be sharp, and plan on at least 1.6 mm for inside edges, which is the common practice the zinc design rules describe. On aluminum, one die caster's guide sets 0.06 in (1.524 mm) as the minimum along the edges of metal savers. Pair each inside radius with an outside radius equal to that radius plus the wall, so the section stays the same thickness around the bend.

Why does an inside fillet with a sharp outside corner make a heavy spot?

Because the fillet adds metal on the inside of the bend while the sharp outside corner keeps all of its metal. Measured by the largest circle that fits, a corner with both edges sharp is about 1.17 times the wall, and filleting only the inside to a radius equal to the wall raises that to about 1.51 times. Giving the outside a radius of the inside radius plus the wall brings it back to exactly one wall thickness.

Ask JCH about die cast walls

Wondering whether a wall can be cast as drawn, or whether a corner needs a different radius? Type the question here. The assistant answers from what this site publishes, and someone from our tooling team can follow up if you ask.

AI assistant. Answers can be wrong; nothing it says is a quote or a promise.

Want a wall and gate review before the die is designed?

Treat the numbers above as an engineering estimate, then have a person check them. JCH engineers will mark up the drawing for thin walls far from the gate, heavy corners and rib roots, and line up the die caster's fill review with a partner shop from our vetted network.

Book a free 30-minute first consultation Email your drawing
JCH Design & Manufacturing — tooling, injection molding, PCBA, custom packaging, cut-and-sew & QC via vetted partner factories · Book a 30-minute call · jack@jchtrade.com · (321) 323-4474 · Canonical: https://jchtrade.com/tools/die-casting-wall-thickness-guide