PCB Trace Width Calculator
A trace carrying 3 A on an outer layer of 1 oz copper, allowed to warm 10 °C, needs about 74 mil² of cross-section, which is 53.8 mil (1.37 mm) of width, by the IPC-2221 curve fit I = 0.048 · ΔT0.44 · A0.725 that public trace calculators reproduce. Put the same 3 A on an inner layer and the fit asks for 140 mil (3.56 mm).
Type the current, the rise you can live with, the copper weight and the layer. You get the cross-section and the width in mil and millimeters; switch the mode to start from a width you already routed and read the current it supports instead. A length and an ambient temperature add resistance, voltage drop and the power the trace turns into heat.

Engineering estimate, not a quote. The fit is a chart curve, not a thermal model of your board: copper planes, nearby hot parts, airflow, the enclosure and the copper thickness actually delivered can all shift the real temperature.
How this works
The question a trace-width chart answers is narrow: how much copper cross-section keeps a conductor's steady temperature rise at or below a chosen number of degrees for a given current. Advanced Circuits prints the curve fit behind its calculator as “Area[mils^2] = (Current[Amps]/(k*(Temp_Rise[deg. C])^b))^(1/c)” followed by “Width[mils] = Area[mils^2]/(Thickness[oz]*1.378[mils/oz])”, with b = 0.44 and c = 0.725 for both layer types, k = 0.048 for external layers and k = 0.024 for internal ones, and calls k, b and c “constants resulting from curve fitting to the IPC-2221 curves.” NextPCB's design guide prints the same constants, the same 1.378 conversion, and a quick-reference table worked from them. Turned around, the fit reads I = k · ΔT0.44 · A0.725, which is the form this page uses when you start from a width.
The units are part of the fit. The constants hold only in the units they were fitted in: current in amperes, rise in degrees Celsius, area in square mils. One mil is a thousandth of an inch, exactly 0.0254 mm by NIST SP 811, so one square mil is 0.00064516 mm². Feed the formula square millimeters, or a rise in Fahrenheit degrees, and it returns a wrong answer without complaint. The calculator converts only at its edges and keeps the arithmetic in the fitted units.
From area to width. A trace's cross-section is its width times its copper thickness, so the width follows once thickness is known. Board copper is ordered by weight per area. Both sources named above convert at 1.378 mil per ounce per square foot, which is 35.0 µm. As a cross-check we worked the conversion from first principles: NIST SP 811 gives 1 oz/ft² as 0.3051517 kg/m², and NIST Handbook 100 gives the international standard density of copper at 20 °C as 8.89 g/cm³, so one ounce spreads to 0.3051517 ÷ 8.89 = 34.3 µm (1.351 mil), about 2 percent thinner than the calculators' figure (our arithmetic). The page keeps 1.378 because that value is published alongside the fitted constants. IPC-2152's definitions add a caution about the unit itself: copper weight is “typically expressed in ounces per square foot or grams per square centimeter (these units are not equivalent).” Finished copper is a separate matter again. IPC-2221C lists tables titled “Internal Layer Foil Thickness After Processing” and “Thickness of External Conductor of the Finished Printed Board after Plating”; those tables are in the paid standard and we have not read them, so ask your fabricator what finished thickness they hold and enter it under “Other weight” if it differs.
Outer versus inner layers. The only thing the fit changes between layers is k, which halves for an internal trace. Because area goes as k−1/0.725, halving k multiplies the required area by 21/0.725 = 2.60. Advanced Circuits explains the split this way: in air the outer layers lose heat by convection, while “a good heat insulator blankets the internal layers.” Newer data disagrees. KiCad's track-width documentation says its calculations use “the closed-form equations fit by Douglas Brooks and Johannes Adam to the IPC-2152 data,” and that “IPC-2152 found that internal traces cool about as well as external ones.” This page reproduces only the older curves, so read its internal-layer widths as the old charts' answer, not as a measured property of your stack-up.
Resistance, drop and heat. Once the cross-section is fixed, resistance is ordinary conductor arithmetic. The reference copper values come from NIST Handbook 100: the International Annealed Copper Standard resistivity of 0.017 241 Ω·mm²/m for 20 °C, equal to a conductivity of exactly 58 m/(Ω·mm²), and a temperature coefficient for standard copper of 0.00393 at 20 °C; the handbook's tables assume resistance is linear in temperature up to 200 °C. The calculator evaluates the copper at ambient plus the allowed rise, since that is the temperature the trace is being sized to reach (our choice; a cold-board figure would read lower). Resistance is R = ρT × L ÷ A, the drop is I × R, and the heat released is I² × R. The annealed standard was written for wire; applying it to etched and plated board copper is an assumption you should confirm with the fabricator.
Where the curves stop
Advanced Circuits states that the graphs behind its tool “only cover up to 35 Amps, up to 0.4 inches of trace width, from 10 to 100 degrees C of temperature rise, and copper of 0.5 to 3 ounces per square foot,” and that its formulas “will simply extrapolate” past those limits. NextPCB lists the same four limits. This calculator still computes outside them, but it says so in the headline result, because an extrapolated width has no chart data behind it. At 1 oz and a 10 °C rise the 0.4 in width limit arrives early: about 12.8 A on an outer layer and 6.4 A on an inner one, long before 35 A.
Worked example: a 5 A feed, then a width check
A 5 A supply feed runs 150 mm across an outer layer of 1 oz copper, and the design allows a 20 °C rise over a 25 °C ambient. Press Load the 5 A, 150 mm example to reproduce steps 1 to 4 in the calculator, then Load the 25 mil check for step 5.
Three results are worth reading twice. Doubling the copper weight halves the width at the same area, which takes the feed from 1.82 mm to 0.91 mm. Moving it inside widens it to 4.72 mm, 2.60 times the outer figure, purely by the fit's internal-layer constant. And the finished trace drops 0.22 V while turning 1.12 W into heat along its 150 mm; check both against the regulator and the load, since the width rule by itself says nothing about either one.
Checked against a published table. We ran the calculator's own code on three rows of NextPCB's quick-reference table, which lists widths for 1 oz copper and a 10 °C rise: 1 A outer returns 11.83 mil against the table's 11.8 mil (0.30 mm); 2 A inner returns 80.03 mil against 80.0 mil (2.03 mm); 10 A outer returns 283.23 mil against 283.2 mil (7.19 mm).
The scaling rules inside the exponents
Because the fit is a power law, its sensitivities come straight out of the exponents. Required area goes as I1/0.725 = I1.379, so doubling the current multiplies the copper by 2.60, not 2. Area goes as ΔT−0.44/0.725 = ΔT−0.607, so relaxing the rise from 10 °C to 20 °C cuts the area to 0.657 of its value, a 34 percent reduction, and a 40 °C rise cuts it to 0.431 of the 10 °C figure. Copper weight enters only through thickness: at a fixed area, width goes as 1 ÷ weight. On choosing the rise, Advanced Circuits writes that “Ten degrees is a very safe number to use for just about any application” and, for tighter routing, “ask for 20 degrees of temperature or more”; its same answer adds that the right allowance depends on “the operating environment and the type of PWB material used.”
IPC-2221 and IPC-2152: what we can and cannot tell you
IPC's public contents pages show two documents in play. IPC-2152, Standard for Determining Current Carrying Capacity in Printed Board Design, is dated August 2009 and gives its purpose as guidance on “determining the appropriate conductor sizes on the finished PB as a function of the current carrying capacity required and the acceptable conductor temperature rise.” Its contents list separate still-air and vacuum chart sets for internal and external conductors, sections on parallel conductors, vias, copper planes, board thickness and board material, and a reference section titled “The Origin of the First Conductor Sizing Chart.” IPC-2221, the Generic Standard on Printed Board Design, is now at Revision C, dated December 2023, which supersedes Revision B of November 2012; its section 10.1.1 is headed “Conductor Width and Thickness.” A standards reseller lists both as the “Current revision” and sells them, and we did not consult the full text of either.
That sets the limits of this page. The constants above come from public calculators that attribute them to IPC-2221 curves; we have not checked them against any edition of the standard, and neither publisher says which revision the fit was drawn from. KiCad's documentation treats the newer data as the replacement; it says the IPC-2152 data “superseded the older IPC-2221 charts in 2009.” NextPCB calls IPC-2221 “intentionally conservative” and says IPC-2152 “factors in board thickness, adjacent copper coverage, and more detailed thermal test data.” We print no IPC-2152 value here. If your customer, drawing or contract names IPC-2152, buy it and size from its charts, or from a fit that names its source and coefficients.
Common mistakes
- Reading the result as a current rating for the whole path. The fit limits one trace's temperature rise. It says nothing about voltage drop at the load, or the rating of the connector, via or component pin at either end.
- Mixing units inside the equation. The constants expect amperes, °C and square mils. A square-millimeter area, or a rise typed in Fahrenheit degrees, produces a confident wrong number.
- Sizing only the long straight run. Where a route necks down to reach a pad or slip between pins, its cross-section is smaller. Put that narrowest width through current mode to see what the section supports.
- Treating nominal weight as finished thickness. 1.378 mil per ounce is a calculation convention. The copper on your board after etching and plating is whatever the fabricator's process leaves, and IPC keeps its finished-thickness tables in the paid standard.
- Trusting extrapolated output. Past 35 A, past 0.4 in of width, outside a 10 to 100 °C rise or outside 0.5 to 3 oz, the result rests on no chart data. Heavy feeds hit the width limit first.
- Confusing rise with final temperature. ΔT is the climb above ambient. A 20 °C rise in a 50 °C enclosure puts the copper at 70 °C, and that sum is what the board material and the parts nearby must tolerate.
- Copying a single-trace answer onto parallel paths. IPC-2152's contents give parallel conductors and vias their own sections; this fit models neither.
Picking the right method for the decision
| Method | Use it for | Where it stops |
|---|---|---|
| This calculator | A first-pass width for one trace from current and rise; the current a routed width supports; resistance, drop and I²R heat | IPC-2221-attributed fit only; one isolated trace; extrapolates outside 35 A, 0.4 in, 10 to 100 °C and 0.5 to 3 oz |
| IPC-2152 charts (purchased standard) | Designs, customers or contracts that cite IPC-2152; inner-layer power; plane and board-thickness effects | Paid document; pick the chart set that matches the environment, still air or vacuum |
| A calculator built on an IPC-2152 fit, such as KiCad's track-width tool | A quick comparison against the newer data set | Check which fit and coefficients it states before trusting it |
| Fabricator's stack-up sheet | Finished copper thickness and tolerance on each layer | Covers one build at one shop |
| Thermocouple or thermal camera on a powered prototype | Dense power boards, enclosed or potted assemblies, settling a disputed margin | Needs real hardware at the real load and ambient |
Sources for the method and constants
Every source below was fetched and read for this page on November 20, 2026. The curve-fit equations, the constants k = 0.048 and 0.024, b = 0.44 and c = 0.725, the 1.378 mil per ounce conversion, the four source-chart limits, the convection explanation, the potted-assembly advice and the rise guidance are from the Advanced Circuits trace width calculator. The same constants, the same limits, the 1 oz, 10 °C quick-reference table used as test cases, and the “intentionally conservative” remark are from NextPCB's IPC-2221 trace width guide. The Brooks and Adam fit, the 2009 supersession statement and the internal-cooling finding are quoted from KiCad's track-width formula documentation. IPC-2152's date, purpose, definition of copper weight and contents are from IPC's public IPC-2152 contents file; IPC-2221C's date, the revision it supersedes and its section and table titles are from IPC's public IPC-2221C contents file. The exact mil and the oz/ft² factor come from NIST SP 811, Appendix B.8. Current-revision status and sale are from the reseller listings for IPC-2152 and IPC-2221 Revision C. NIST Handbook 100 (the copper wire tables) supplies the resistivity, its temperature coefficient, the linear-to-200 °C assumption and the 8.89 g/cm³ density.
Reviewed by the JCH tooling team · updated November 2026.
Trace width questions, answered
What trace width do I need for 1 A?
With 1 oz copper on the board surface, held to a 10 °C rise, the IPC-2221 fit gives roughly 16.3 square mils, a line about 11.8 mil or 0.30 mm wide. Buried on an inner layer, that same amp calls for about 30.8 mil, or 0.78 mm. Letting the outer trace climb 20 °C instead trims it to near 7.8 mil.
Why does an inner-layer trace have to be wider?
In the older chart fit, k drops from 0.048 to 0.024 once the conductor sits between laminate sheets, and since copper area scales with k to the power −1/0.725, the requirement grows by a factor near 2.6. Advanced Circuits puts this down to convection cooling the surface traces. The IPC-2152 data, as KiCad's documentation summarizes it, found buried and surface conductors shed heat about equally, so the gap may be smaller than the legacy rule implies.
What temperature rise should I design for?
Treat it as an allowance set by the hottest surroundings the product will see and by what the laminate and neighboring parts can stand. Advanced Circuits calls ten degrees a safe pick for almost any job and suggests twenty or more when routing space is tight. Whatever you choose, add it to worst-case ambient and compare the total with the board and component ratings.
How thick is 1 oz copper on a circuit board?
The two published sources this page draws on count each ounce per square foot as 1.378 mil, or 35.0 micrometers, so 2 oz is 2.756 mil and half an ounce 0.689 mil. Dividing the NIST areal-mass figure by copper's handbook density lands a little lower, near 34.3 micrometers. What a finished board carries after etching and plating depends on the process, so get that number from whoever builds it.
Is IPC-2221 still valid now that IPC-2152 exists?
IPC-2221 is still published as a generic design standard, now in Revision C from December 2023. For current sizing, KiCad's notes describe the 2009 IPC-2152 data as replacing the old IPC-2221 charts, and the newer document has chart sets for vacuum service plus sections on planes and board thickness. The legacy fit stays handy as a fast first pass you can check by hand; when a customer or contract names IPC-2152, size from that document.
How do I calculate the voltage drop along a trace?
Take copper's resistivity, 1/58 ohm-square-millimeter per meter at 20 °C, raise it by 0.393 percent for each degree above 20 °C, multiply by the length in meters and divide by the cross-section in square millimeters. Multiply that resistance by the current for the drop. A 150 mm outer trace of 0.0636 mm² at 45 °C comes to about 45 milliohms, so 5 A loses roughly 0.22 V.
Can I carry more current by repeating a trace on two layers?
Copper repeated on several layers shares the load, but this fit sees one conductor at a time and knows nothing about the vias tying the layers together or how close the paths run. For a first estimate, by our reading, split the current in proportion to each layer's cross-section, since equal lengths at equal temperature share current that way, size each path for its share, then confirm on a powered prototype.
Ask JCH about a board inside your product
Wondering whether a power trace fits the board outline your enclosure allows, or how to brief a fabricator on copper weight? Type it in the box; an AI helper replies in a panel at the lower right of the screen. After that first reply the panel also offers an optional email field for a follow-up, which you can skip.
This assistant is software, so its answers can be wrong. For anything touching safety, your board specification wins.
Laying out power on a board that goes into a molded housing?
Trace width is one line on a longer list that also covers board outline, connector placement, potting, airflow and the housing that holds it all. Our tooling team can review the board and enclosure drawings side by side, then coordinate the board build and the molded parts with a board shop and a molder we work with.
Book a free 30-minute first consultation Send a drawing