They describe how a plastic behaves in small lab flame tests. HB burns slowly when horizontal. V-2, V-1 and V-0 self-extinguish when vertical, with V-0 the fastest and no flaming drips. 5VB and 5VA survive a much larger flame. Each rating applies only to the tested grade, color and thickness, not automatically to your finished part.
UL 94 is a set of small-scale lab tests on molded specimens of a plastic. It tells you how a material behaves once it has caught a small flame: does it keep burning, how fast, does it go out on its own, and does it drip burning plastic. UL lists twelve classifications. Six apply to the solid plastics used for enclosures, structural parts and insulators: 5VA, 5VB, V-0, V-1, V-2 and HB. Three apply to low-density foams (HF-1, HF-2, HBF) and three to thin films that can't hold themselves up (VTM-0, VTM-1, VTM-2).
The rating belongs to a material at a stated thickness and color, not to your part. A V-0 resin doesn't make a V-0 product. Whether a finished product meets its fire requirements is decided under the end-product safety standard that applies to it, and that standard usually specifies the minimum material flame class, often at the thinnest wall in the relevant area. UL 94 is the input; the product evaluation is a separate step.
A bar is held horizontally and a 20 mm flame is applied for 30 s. The rating is a burn rate: at most 40 mm/min for specimens 3 to 13 mm thick, at most 75 mm/min for specimens under 3 mm, or the flame goes out before the first mark. HB is the lowest rung. It says the material burns slowly, not that it stops burning.
Five bars are conditioned (48 h at 23 °C and 50% relative humidity, and another set 168 h at 70 °C in a hot-air oven), then hung vertically. A 20 mm flame is applied to the bottom end for 10 s, removed, and applied again for 10 s as soon as the first burn stops. The lab times the afterflame and afterglow and watches whether drips ignite a cotton pad underneath.
V-0 is the tightest: each burn goes out within 10 s, the ten burns total 50 s or less, and nothing that drips lights the cotton. V-1 allows 30 s per burn and 250 s total, still with no cotton ignition. V-2 has the same times as V-1 but allows flaming drips that light the cotton. That last difference is easy to overlook and often matters most, because a burning drip can carry fire to whatever is below the part.
The 5V tests use a 500 W, 125 mm flame, roughly five times more severe than the V test flame, applied up to five times. To pass, burning and glowing must stop within 60 s after the fifth application, and no burning drips are allowed. The test also checks flat sheet specimens for holes: 5VB allows the flame to burn a hole through the sheet; 5VA does not. 5VA is the highest UL 94 classification; some end-product standards call for a 5V rating on larger enclosures, so check yours.
One trap: VTM ratings come from a different, gentler test for thin films (3 s flame applications), and UL says plainly that VTM-0 is not equivalent to V-0.
A resin's flame rating is only valid at the thickness it was tested at, and thinner sections usually perform worse. One prototyping house gives the example of a resin that passes at 1.5 mm and fails at 0.74 mm. You can see thickness-specific listings on any datasheet. Covestro's data for a general-purpose clear polycarbonate, Makrolon 2407, lists UL 94 V-2 at 0.75 mm and HB at 2.7 mm. INEOS Styrolution lists its general-purpose ABS, Terluran GP-22, as HB at both 1.5 mm and 3.0 mm. Neither is a flame-retardant grade, and neither would satisfy a V-0 requirement; flame-retardant versions of the same resin families exist for that.
The practical rule is to compare the rating thickness against the thinnest wall in the area that matters, not the nominal wall. Vent louvers, snap arms and the floor of a deep pocket are where parts go thin; the wall thickness checker and our page on wall thickness help find those spots before the material is locked in.

When a material passes UL's testing and earns a UL Recognized Component Mark, UL issues a "Yellow Card" that lists its tested properties, and the record can be looked up in UL's online plastics database. For flammability, read four things on each line:
Get the actual card, not a line on a sales sheet. And keep in mind that a resin supplier's word that a grade "is V-0" means nothing without the thickness and color; the material compliance documentation page covers what paperwork to request with each lot.
A hypothetical housing has a 2.0 mm main wall, vent slots whose ribs are 1.2 mm thick, and snap arms at 1.0 mm. The test lab says the end-product standard needs V-1 or better for the enclosure material at its thinnest section. The brand color is a light gray. Three candidate flame-retardant grades come back from the resin supplier:
| Candidate | Yellow card line | Verdict |
|---|---|---|
| Grade A | V-0 at 1.5 mm, color NC | Fails twice: 1.5 mm is thicker than the 1.0 mm snap arms, and NC doesn't cover gray |
| Grade B | V-0 at 1.5 mm, V-2 at 0.8 mm, color ALL | Fails: at the 1.0 mm snap arm, the only rating that covers it is the 0.8 mm V-2 line, which is below the V-1 target |
| Grade C | V-0 at 0.75 mm, color ALL | Passes at every section from 1.0 mm up, in any color |
Grade C it is, or the snap arms get thickened to suit Grade B's numbers and the lab confirms that's acceptable. Then lock it down: the drawing names Grade C, the color is made with a colorant the resin supplier confirms doesn't affect the rating, and the material certificate for each lot shows the grade. Our color matching and coloring methods pages cover the color side.
If the part isn't an enclosure or support for live electrical parts, and no product standard calls for a flame class, a rating may not be needed at all, and paying for an FR grade buys nothing. If the part is a large enclosure, the standard may call for 5VA or 5VB rather than V-0. And if the product mixes plastic and electronics in one housing, the material decision belongs alongside the electrical design; see plastic and electronics enclosures.
For flame behavior, yes. In the vertical test, V-0 bars stop burning within 10 s per application and do not drip burning plastic onto the cotton. V-2 bars may burn up to 30 s and may drip flaming particles that ignite the cotton. Which one you need depends on the end-product standard, not on preference.
No. UL 94 rates a material at a tested thickness and color. The finished product is judged under its own end-product safety standard, which looks at the actual design, wall thicknesses, openings and what sits around the part. A V-0 material is usually a requirement within that evaluation, not a substitute for it.
Both survive five applications of a flame about five times more severe than the V test, stop burning and glowing within 60 s after the last one, and drop no burning particles. In 5VB the flame may burn a hole through the flat sheet specimen; in 5VA it may not. 5VA is the highest UL 94 classification.
It can. Recognition is formulation-specific, and pigments and carriers change the formulation. That is why yellow card lines carry a color code such as ALL, BK or NC. If your color is not covered, ask the resin supplier whether the rating extends to it, and get that in writing.
Not really. HB only shows that a horizontal bar burns slower than a set rate, 75 mm/min for specimens under 3 mm thick or 40 mm/min for 3 to 13 mm. Many ordinary, non-flame-retardant resins rate HB. If a requirement calls for self-extinguishing behavior, it means a V or 5V rating.
Send the part file and the quantity you expect to run, and we'll review it before you commit to tooling. NDA first if you want one.
Send a part for reviewBook a 30-minute call