Injection Pressure Converter: Hydraulic to Plastic Pressure
On a hydraulic press, the melt pressure in front of the screw equals, with losses neglected, the oil pressure in the injection cylinder multiplied by the press’s intensification ratio, which is the effective ram area divided by the screw tip area. At a ratio of 10:1, 800 psi of hydraulic pressure gives roughly 8,000 psi of plastic pressure, which is 55.16 MPa, 551.6 bar or 562.5 kgf/cm².
Type a gauge reading, or the melt pressure you are aiming for. Then supply the ratio directly, derive it from the two maximum pressures on a spec sheet, or compute it from screw diameter and cylinder area. You get the answer in MPa, psi, bar and kgf/cm², the ratio that produced it, a check against the press’s hydraulic ceiling, and the setpoint a second press would need to put the same pressure on the melt.
Ratio arithmetic on nominal figures, not a quote. Autodesk’s method multiplies by the ratio “neglecting losses,” and so does this page, so read every result as pressure at the screw tip rather than in the part.
How this works
A hydraulic injection unit is a force converter. Oil pushes on a large ram, the ram drives the screw forward, and the screw tip, with its check ring shut, behaves as a small plunger on the melt. Force is pressure times area, so one force spread over a smaller face shows up as a higher pressure. John Bozzelli’s 2016 column in Plastics Technology writes the law as “F = P × A” and illustrates it with a 150 cm² ram driving a 15 cm² check valve, which raises the hydraulic pressure “by a factor of 10.” He stresses that the ratio is built from “areas, not diameters,” so a screw diameter must be squared before it is compared with a ram.
Names shift from one document to the next, and that matters when you read a setup sheet. RJG’s explainer defines hydraulic pressure as “The pressure in the injection cylinder, generated by the resistance to the flow of oil delivered by a hydraulic pump,” and specific pressure as “Also known as injection or plastic pressure, this is the actual material pressure within the screw and barrel assembly generated by a resistance to the flow of plastic in front of the screw during injection.” It adds: “Typically, hydraulic injection molding machines display hydraulic oil pressure. Some will also display specific pressure.” Bozzelli notes that builders print the plastic figure under labels such as “injection pressure” or “specific pressure.” Autodesk’s help page places the hydraulic reading somewhere else, as “the pressure in the main supply line from the pump,” which is one reason the spec-sheet route below needs care. Everything this converter outputs on the plastic side is specific pressure in RJG’s sense.
Three ways to find the ratio
From the hardware. Divide the effective ram area by the screw tip area. Bozzelli calls this the best method and, in the same breath, “not practical,” because “you will spend hours looking for the hydraulic ram area and in some cases, it cannot be found in the machine manuals.” If you do have the bore, enter it with the cylinder count; for twin-cylinder units the converter adds the two piston faces. Whether the full face or a rod-side annulus pushes during injection depends on how the unit is plumbed, so check the drawing (our reading).
From the spec sheet and the controller. Bozzelli’s practical route takes the maximum plastic pressure for the installed screw from the builder’s table and the highest hydraulic injection pressure the controller lets you set, then divides: “Ri = Maximum injection (plastic) pressure ÷ maximum hydraulic pressure for the injection unit.” His example is 26,500 psi over 2,250 psi, giving 11.78:1. His warning about the second number is direct: “Do not take it from the machine specifications, as they may list pump pressure, which is different from the pressure in the hydraulic cylinder.”
From a graph in the manual. Autodesk’s Moldflow help describes picking a round hydraulic value, “for example 100 bar,” projecting up to the curve for the screw in use, reading across to injection pressure and dividing. Type the two numbers you read into the spec-sheet fields and the converter does the division.
What range to expect. Autodesk states: “A typical ratio is 10, and the typical range of the ratio is between 7 and 15.” Bozzelli writes that “most early machines were made with a 10:1 ratio” but that “Today you can buy machines with intensification ratios ranging from 6:1 to 43:1. Custom machines can go even higher.” The converter flags a ratio outside Autodesk’s 7 to 15 band or outside Bozzelli’s 6 to 43 span, and still computes it.
Converting MPa, psi, bar and kgf/cm²
All four are units of pressure, so each conversion is one multiplication through the pascal. NIST SP 811, Appendix B.9, under “Pressure or Stress (Force Divided by Area),” gives psi as 6.894 757 E+03 Pa, bar as 1.0 E+05 Pa and kilogram-force per square centimeter as 9.806 65 E+04 Pa. NIST prints exact factors in bold, and both the bar and the kgf/cm² rows are bold; the psi factor is not, and is given to seven significant digits. The same table lists the technical atmosphere (at) at 9.806 65 E+04 Pa, the identical value to kgf/cm².
The bar is not an SI unit. Chapter 5 of SP 811 puts it in Table 9, “Other non-SI units accepted for use with the SI,” with “1 bar = 0.1 MPa = 100 kPa = 1000 hPa = 105 Pa.” The guide adds that such units “must not be introduced in fields where they are not presently used” and that it “strongly discourages the continued use of these units by NIST authors except when absolutely necessary.” The kilogram-force sits further down, in Table 11, “Example of other unacceptable units.” Those are instructions for NIST’s own publications. The converter accepts both units so that a reading can be typed exactly as the gauge or sheet shows it, and it reports MPa alongside every result.
| 1 unit of | MPa | bar | psi | kgf/cm² |
|---|---|---|---|---|
| MPa | 1 | 10 | 145.0377 | 10.19716 |
| bar | 0.1 | 1 | 14.50377 | 1.019716 |
| psi | 0.006894757 | 0.06894757 | 1 | 0.07030696 |
| kgf/cm² | 0.0980665 | 0.980665 | 14.22334 | 1 |
One kgf/cm² is 1.93 percent smaller than one bar, close enough for the two to be swapped by mistake on a handwritten sheet. A melt pressure of 1,500 bar is 1,529.6 kgf/cm², so reading one unit as the other moves the number by about 30.
Worked example: the three cases, computed long-hand
The buttons above the form load each one. Case 1 uses Bozzelli’s numbers as printed. Case 2 reads one press’s spec sheet, with a 12 MPa gauge reading that we chose for illustration. Case 3 puts Bozzelli’s illustrative areas and his Machine A and B story through the geometry route.
Case 1 is the reason the ratio belongs on every setup sheet: an identical hydraulic number put 27.5 percent more pressure on the melt once the mold changed machines. Bozzelli’s rule for it is “Duplicate plastic variables, not machine variables, to get consistent parts.” Case 3 is the same lesson seen from the other side. A mold that needs 23,000 psi cannot run on a 10:1 press whose oil side stops at 2,000 psi (our reading of his figures), however the process is tuned, while the 14.6:1 press clears the requirement at 79 percent of its hydraulic range.
One press, four screws: what a spec sheet shows
The Absolute Haitian JU16000III-22300W sheet (Rev 2, January 13, 2022) lists four screws, A to D, of 140, 150, 160 and 170 mm, with “Injection Pressure (max)” of 211, 184, 162 and 143 MPa, and a “Max Pump Pressure” of 25 MPa. Multiply each pressure by its diameter squared and the products land between 4.133 and 4.147 million, a spread of 0.35 percent. In our reading, that is one injection cylinder delivering one force to four tip areas, which is the area law in Figure 1 showing up in a builder’s table. Divided by the pump figure, the four ratios come to 8.44, 7.36, 6.48 and 5.72. Those are quotients against pump pressure, the number Bozzelli warns against; if the controller caps injection below 25 MPa, each true ratio is higher. The sheet’s psi column (30,603, 26,687, 23,496 and 20,740) matches the NIST factor to the last printed digit.
What the number does not tell you
Cavity pressure. RJG is plain that “cavity pressure is significantly lower than specific pressure,” because “We lose pressure through the orifice of the nozzle tip, the sprue, the runner system, and the gate.” Bozzelli’s 2011 column on pressure loss gives an extreme case: a PC insulator filled 96 percent, a transfer reading of 2,040 psi hydraulic on a 14.7:1 press, “So the pressure in the nozzle is 29,988 psi,” and since “If the part is short we know the plastic pressure at the end of flow is zero,” all of it was spent in the flow path.
Backpressure. Bozzelli’s 2016 column multiplies a 75 psi hydraulic backpressure by 11.78 to get 884 psi. Robert Gattshall, writing in the same magazine in 2022, reports nozzle-transducer readings during screw recovery that “confirmed my concerns that using an intensification ratio (Ri) for backpressure is not an accurate reflection of backpressure,” and concludes “It is more accurate to leave it as a hydraulic setpoint than to multiply it by the Ri since there is no intensifying of the screw diameter moving backwards.” He expects the melt ahead of the screw to sit “just north of the hydraulic pressure reading at that valve.” Choose backpressure in the form and the result shows both readings side by side.
Software limits. Gattshall also describes a vertical press whose smaller screw lifted the ratio to 20:1, so a 3,300 psi hydraulic maximum meant 66,000 psi of plastic pressure on paper, while the builder programmed “a maximum injection pressure of right around 30,000 PPSI” to protect the mold. A ceiling computed here is the hydraulic arithmetic; the controller can be set lower.
Mistakes that give the wrong pressure
- Copying a hydraulic setpoint to a different press. Case 1 shows the jump. Carry the plastic figure, then divide by the receiving press’s ratio.
- Dividing by pump pressure. A sheet’s pump rating can differ from what the cylinder sees, which skews the ratio. Use the injection limit on the controller.
- Comparing diameters instead of areas. A ram 3.162 times the screw diameter has 10 times its area. Using the diameter ratio understates the melt pressure by that same factor of 3.162.
- Keeping the old ratio after a screw change. On the JU16000III sheet, moving from screw A to screw D drops the maximum from 211 to 143 MPa against the same 25 MPa pump rating, a 32 percent fall.
- Calling nozzle pressure cavity pressure. The converter stops at the screw tip; only a sensor in the mold reads the cavity.
- Treating bar and kgf/cm² as one unit. The 1.93 percent gap stacks on top of every other rounding on the sheet.
This converter, the spec table, or a sensor?
| Approach | Use it for | Limit |
|---|---|---|
| This converter | Translating setpoints between hydraulic and plastic units, moving a process between presses, checking a press can reach a melt pressure | Only as good as the ratio entered; flow losses are not modeled |
| Builder’s spec table or manual graph | The plastic-pressure ceiling for a named screw | The hydraulic figure may be pump pressure |
| Nozzle pressure transducer | Actual melt pressure; Autodesk notes it “can be measured directly by locating a transducer in the nozzle” | Needs an instrumented nozzle |
| Cavity pressure sensors | What the part itself sees during fill and pack | The mold has to be built or modified for them |
| Tonnage calculator and ton-force converter | Clamp force, which is pressure times projected area, and its units (tons, kN) | Force, not pressure; bring the force figures there |
Sources
Intensification ratio definition, the 150/15 cm² example, the 800 psi, 12.75:1 and 627 psi figures, the 26,500/2,250 psi spec-sheet method, the 6:1 to 43:1 range, the pump-pressure warning, the 1:1 electric statement and the Machine A and B pressures: Bozzelli, “Understanding Intensification Ratio,” Plastics Technology, December 27, 2016. The 2,040 psi, 14.7:1 and 29,988 psi short-shot case: Bozzelli, “Understanding Pressure Loss in Injection Molding,” Plastics Technology, January 4, 2011. Backpressure findings, the 20:1 screw change and the software limit: Gattshall, “What is Backpressure and How Should We Calculate It?” Plastics Technology, August 30, 2022. Pressure definitions and losses: RJG, “What Is the Difference Between Hydraulic, Specific, and Cavity Pressure?” July 14, 2021. The Pm = Ph (Ah / Am) formula, the 7 to 15 range, the graph method and the losses note: Autodesk Moldflow Insight help, “Calculating the machine intensification ratio”. Unit factors: NIST SP 811 Appendix B.9; status of the bar and the kilogram-force: NIST SP 811 Chapter 5. Screw and pressure table: JU16000III-22300W specification sheet. All pages were read on November 20, 2026. The constant-force fit, the pump-pressure quotients, the 2,000 psi ceiling in Case 3 and the twin-cylinder area rule are our own arithmetic (our reading).
Reviewed by the JCH tooling team · updated November 2026.
Pressure conversion questions
How do I convert hydraulic pressure to injection pressure?
Multiply the oil reading by the machine's intensification ratio. On a press built at 10 to 1, a gauge showing 1,000 psi corresponds to roughly 10,000 psi of melt pressure, or 68.9 MPa. Servo-electric machines skip this step, since RJG notes that their screens read specific injection pressure rather than oil pressure.
What is a normal intensification ratio for an injection molding machine?
Autodesk's Moldflow help names 10 as the typical value and 7 to 15 as the typical spread. Bozzelli wrote in 2016 that buyers could get presses anywhere from 6:1 up to 43:1, and custom builds beyond that. Take any single figure as a starting guess and confirm it for the screw fitted in your barrel.
Is bar an SI unit?
No. NIST SP 811 lists the bar in Table 9, among non-SI units the CIPM allowed to stay in use alongside the SI, defines it as exactly 100 kPa, and asks NIST authors to avoid it where they can. Ten bar make one megapascal.
How many psi are in one kgf/cm²?
About 14.2233. One kilogram-force per square centimeter is exactly 98.0665 kPa, while one psi is 6.894757 kPa by NIST's seven-digit factor; divide the first by the second and you get 14.2233. NIST's Appendix B.9 gives the technical atmosphere (at) the same figure.
Why does the same mold need a different hydraulic setting on another press?
Each machine multiplies oil pressure by its own ratio. In Bozzelli's comparison, the press built at 12.75:1 reached 10,200 psi on the melt from the hydraulic number that gave 8,000 psi on a 10:1 press, so matching the first machine took about 627 psi. Move the melt figure between presses, then divide by each machine's ratio.
Does the converter give cavity pressure?
No. It reports melt pressure at the front of the screw. Pressure falls at every restriction between barrel and part, so the cavity sees less, and RJG points out that reading it requires sensors built into the mold.
Should backpressure be multiplied by the intensification ratio?
Plastics Technology writers disagree. Bozzelli's 2016 column scales 75 psi of hydraulic backpressure to 884 psi on the melt. Gattshall's 2022 column, after watching a nozzle transducer during recovery, argues the setpoint should stay in hydraulic units because nothing intensifies while the screw retreats. The converter prints both figures when you pick backpressure.
Ask JCH about press pressures
Moving a mold between machines, or holding a setup sheet that mixes oil and melt numbers? Type it below. Your text, plus the most recent converter result, is passed to Ask JCH, an AI assistant on this site. Once it has answered, its panel offers an optional email field for anyone wanting a follow-up message.
Machine-generated text, which may contain errors. Check each pressure with the machine builder’s documents before it goes on a controller; no answer is a quote.
Moving a mold to another press?
Send the setup sheet and the spec tables for both machines. Our tooling team will restate every pressure on a plastic-pressure basis, note which ratio each figure rests on, and mark any step the receiving press cannot reach.
Book a free 30-minute first consultation Send a setup sheet