An IP rating is a code from IEC 60529: the first digit (0 to 6) rates protection against solid objects and dust, the second (0 to 9) against water. It reports how a finished, assembled product did in set tests, not a property of the plastic.
The IP code comes from IEC 60529, which the IEC webstore lists under the title "Degrees of protection provided by enclosures (IP Code)". The listing says the standard "applies to the classification of degrees of protection provided by enclosures for electrical equipment with a rated voltage not exceeding 72,5 kV." The version on sale is consolidated edition 2.2, which combines the second edition of 1989 with amendment 1 of 1999 and amendment 2 of 2013. The same listing names IEC technical committee TC 70 as the owner and gives a stability date of 2027. Wikipedia's IP code entry notes that CENELEC publishes the code in the European Union as EN 60529, and The Enclosure Company adds that the UK edition is BS EN 60529.
The two letters cause some confusion. The Enclosure Company says they stand for International Protection in the standard itself, "though almost everyone says Ingress Protection, and either is understood." Its guide also makes the point a buyer most needs: "The code isn't a quality grade or a marketing term. Each digit stands for a specific laboratory test, with a defined probe, nozzle, flow rate, depth or duration." Two numbers on a datasheet are a shorthand for test results, and the rest of this page is about reading that shorthand correctly.
IEC sells the standard, so this page is a buyer's summary of the IEC listing and three published guides: an encyclopedia entry, a testing and certification company and an enclosure supplier, each named where it is used. The test details below are those sources' summaries, not text from the standard. Check anything critical against the edition named in your contract or on the test report.
A full IP code can run to five characters after the letters, though most datasheets use only two. Eurotech's guide to IP testing describes the structure: "The letters IP are followed by two characteristic numerals and, optionally, an additional letter and a supplementary letter." The first numeral covers solid objects and access to dangerous parts, and the second covers water. The letters are rare on enclosure datasheets, but they change what the code means when they appear.
Four rules settle most of the questions a datasheet raises:
The first digit, 0 to 6, rates two things at once. Eurotech describes it as covering "protection of people against contact with hazardous parts inside the enclosure and protection of the equipment against ingress of solid foreign objects." Digits 1 to 4 are probe tests. Wikipedia and The Enclosure Company give the object sizes as 50 mm (the back of a hand), 12.5 mm (fingers), 2.5 mm (tools and thick wires) and 1 mm (most wires and slender screws). The Enclosure Company adds that a jointed test finger is used at digit 2 to check that nothing dangerous can be touched.
Digits 5 and 6 are dust tests, run in a chamber of circulating fine dust that The Enclosure Company identifies as talcum powder. The gap between them is the one buyers most often blur. Wikipedia describes 5, dust protected, as dust that "must not enter in sufficient quantity to interfere with the safe operation of the equipment." Digit 6, dust-tight, means "No ingress of dust." The Enclosure Company is blunt about it: "A 5 is not 'nearly a 6'", because a dust-protected enclosure is allowed to admit dust and a dust-tight one is not. It also notes that for enclosures whose own heating and cooling pump air in and out, which it says describes most electrical enclosures, both dust tests are run with the inside held below atmospheric pressure. Wikipedia gives the dust-tight test duration as up to 8 hours, based on airflow.
For the first digit, a higher number does include the lower ones. In The Enclosure Company's words, "a 6 covers everything a 5 does." That simple ladder does not carry over to the second digit.
The second digit, 0 to 9, climbs through different kinds of test rather than one test made harder. The Enclosure Company summarises the sequence as "drips, then spray, then jets, then immersion", with 9 reserved for hot, high-pressure cleaning. Eurotech lists the equipment: a drip box for 1 and 2, an oscillating tube or hand-held spray nozzle for 3 and 4, a hose nozzle for 5 and 6, an immersion tank for 7 and 8, and a dedicated rig that measures a high-pressure, high-temperature jet for 9. It also says that 9 is the newest numeral, introduced by amendment 2 of 2013, "a protection that cannot be claimed against an older report."
The digits most often seen on enclosure datasheets are 5 and above. The table gives the test each one stands for, as Wikipedia summarises it, and the detail worth asking a supplier to put in writing.
| Water digit | Test, as summarised by Wikipedia's IP code entry | Ask for |
|---|---|---|
| 5 | Water jets from a 6.3 mm nozzle, 12.5 litres per minute, for at least 3 minutes | Confirmation that the jet test was run on the assembled product |
| 6 | Powerful jets from a 12.5 mm nozzle, 100 litres per minute, for at least 3 minutes | The same, plus a separate immersion result if the product can end up under water |
| 7 | Immersion for 30 minutes, with the lowest point 1,000 mm below the surface or the highest point 150 mm below, whichever is deeper | The depth and time actually used |
| 8 | Continuous immersion under conditions the manufacturer specifies; depth and duration are expected to be greater than for 7 | The depth and duration, in writing |
| 9 | Jets of 80 °C water at 8 to 10 MPa (80 to 100 bar), 14 to 16 litres per minute, from 0.10 to 0.15 m | The test report, and whether it was run to IEC 60529 (IPX9) or ISO 20653 (IP69K) |
One detail most charts leave out, according to The Enclosure Company's IP ratings guide: "for every water digit, the standard allows some water to get in." A test passes if whatever enters does not stop the equipment working, does not reach live parts or insulation that is not designed to be wet, and does not collect where it could reach the cable ends. Its example: "An IP67 box that comes out of the tank with a few drops inside can still have passed." If the electronics inside cannot tolerate any moisture at all, that requirement has to be written into the specification on its own line, because the code does not promise it.
Above 6, each water digit is a separate test. Wikipedia says "The ratings for water ingress are not cumulative beyond IPX6," and that a device compliant with IPX7 "is not necessarily compliant with IPX5 or IPX6." Eurotech explains why: numerals 7, 8 and 9 use different apparatus and "verify different failure modes", so a product that needs both jet and submersion resistance "must be verified against both separately." The Enclosure Company says the standard treats an enclosure rated only IPX7 or IPX8 as unsuitable for water jets unless it has also passed the jet test. A seal that holds against still water can still be forced by a moving jet, and the reverse is also true.
IP68 is the code most often misread, because the code does not fix its depth or time. The Enclosure Company says plainly that "IP68 has no fixed depth or time" and gives the example of one IP68 enclosure tested at 2 metres for 24 hours and another at 10 metres for two weeks. Two products both labelled IP68 may have passed very different tests, and neither label alone says which. The same care applies at the top of the scale. Wikipedia says tests with the letter K are defined by ISO 20653, a road-vehicle standard, and are not found in IEC 60529, "except for IPx9, which is the same as the IP69K water test." Neither is a stronger IP68. As The Enclosure Company puts it, "an IP69K enclosure is not necessarily rated for immersion."

Here is how the rules above read on six lines a buyer might meet on quotes or datasheets for a plastic housing. The lines are made up for illustration; the readings follow the sources cited on this page.
| Line on the datasheet (made up) | What it claims | What it does not tell you | What to ask |
|---|---|---|---|
| IP54 | Dust protected (some dust may enter, not enough to stop safe operation); splashing water from any direction | Not dust-tight; no jet or immersion claim | Whether splashing really is the worst water exposure |
| IPX7 | Passed the 30-minute immersion test | Nothing about dust (X means not tested or not claimed); not, by itself, a jet rating | Whether dust and jet tests were run as well |
| IP66/IP67 | Dust-tight; passed both the powerful-jet test and the immersion test | Anything deeper than the IPX7 test; UV, salt or impact performance | One report covering both tests on the same configuration |
| IP68, 1.5 m, 2 h | Dust-tight; immersion to the stated depth for the stated time | Anything deeper or longer; jet resistance unless listed separately | Whether 1.5 m for 2 hours covers the real use |
| IP2XC | Fingers kept out (digit 2); letter C: a tool cannot reach dangerous parts | Any protection against dust or water | Whether the product needs a water rating at all |
| IPX-8 | Not a valid code, because a standard IP code has no hyphens | What was actually tested | The correct code and the report behind it |
The numbers in the IPX7 rule repay a minute of arithmetic, because the rule is "whichever is deeper." Take a small handheld housing 200 mm tall. With its lowest point 1,000 mm down, its top sits 1,000 − 200 = 800 mm below the surface, which is deeper than 150 mm, so the 1,000 mm rule governs. Now take a cabinet 900 mm tall. With its lowest point at 1,000 mm, the top would be only 1,000 − 900 = 100 mm down, which is shallower than 150 mm, so the other rule governs: the top goes to 150 mm and the bottom ends up 150 + 900 = 1,050 mm down. The crossover sits at 1,000 − 150 = 850 mm of height, which matches The Enclosure Company's summary that enclosures 850 mm or taller are tested with the top 150 mm down. For most plastic housings, which are far shorter than 850 mm, IPX7 means the bottom of the part 1 metre down for 30 minutes.
The code is narrow by design. Eurotech says IEC 60529 "explicitly excludes mechanical impacts, corrosion, corrosive solvents, fungus, vermin, solar radiation, icing, condensation and explosive atmospheres from its own scope", leaving those to the relevant product standard. Wikipedia adds that standard IP testing uses fresh water, and that protection against other fluids "such as salt water, oils, or solvents, is not guaranteed by the rating." The Enclosure Company's list of what a rating does not tell you includes impact, which has its own IK rating, along with sunlight and weathering, corrosion, condensation, chemicals, explosive atmospheres and temperature. On plastics it notes that "Some plastics go brittle or chalky outdoors."
For a plastic housing those gaps tend to be material questions. Sunlight and outdoor ageing are covered on our page about UV-resistant plastics for outdoor parts, and flammability is rated separately, for example under UL 94, which is explained on UL 94 flame ratings for plastic parts. Salt spray and fuel or cleaning chemicals need their own specification lines; housings for boats are discussed on marine and boat parts.
North American specifications often use NEMA enclosure types instead, and here the sources disagree. Wikipedia says "Ratings between the two standards are not directly equivalent", because NEMA types also require features and tests, such as operation under icing, that the IP code does not address. Its conversion table lists NEMA 4 and 4X against IP44, IP66 and IP65, while The Enclosure Company, citing NEMA's own table, reads NEMA 4 and 4X across to roughly IP56. With two published tables giving different answers, the safe course is not to convert: ask for the rating under the standard your specification actually names.
No plastic has an IP rating as a material. The Enclosure Company says "An IP rating describes the enclosure as the manufacturer tested it", and for a molded housing that means the shells, seals, fasteners, windows, buttons and every cable entry, assembled the way they ship. Eurotech says IEC 60529 allows an empty enclosure to be tested on its own, but a rating earned on an empty shell "does not automatically transfer once cables, connectors, vents and heat generating components are fitted." It adds that a later change, such as a new cable entry, "calls for retesting rather than reuse of an earlier result."
The weakest part sets the result. The Enclosure Company's example: "An IP66 box with an IP54 gland is an IP54 installation." It also warns that "Modifications made after delivery aren't covered by the maker's test." How a molded housing is designed to reach a given code, with gasket grooves, welded or potted joints and sealed openings, is the subject of our page on waterproof and sealed enclosure molding, and the O-ring groove calculator sizes seal squeeze and gland fill. This page stays with what the code means once a product carries one.
Not the IEC. Eurotech says "IEC publishes the standard but does not test or certify products itself; independent testing laboratories carry out the physical tests." The Enclosure Company answers the question "Who decides an enclosure's IP rating?" with "The manufacturer, on the basis of tests to IEC 60529, often carried out or witnessed by an independent laboratory." Both point a buyer to the same document, the test report, rather than the code printed on a datasheet. Eurotech suggests looking for a laboratory accredited to ISO/IEC 17025, the international standard for testing and calibration laboratories.
Eurotech lists what a proper report states: which clauses of IEC 60529 were used, which edition and amendment applied, and whether the sample was an empty enclosure or the fully populated product. A buyer can reasonably ask for a few more things alongside the report:
These are buyer questions, not requirements quoted from the standard. For how test evidence fits with first-article checks and inspection on a production order, see samples and first articles and quality control and inspection.
This page is a decoder: it is meant to help a buyer read an IP code on a datasheet and ask for the right evidence. It does not say that JCH, its partner factories or any other supplier tests, certifies or guarantees an IP rating for any product; a rating belongs to the product that was tested, and the evidence for it is the report from whoever ran the test. Which rating a product needs depends on what it will actually face, and any product standard that applies to it sits above this summary. For the wider picture of housings that hold electronics, see plastic and electronics enclosures and the electronics enclosures industry page.
The digit was not tested or is not being claimed. Wikipedia says X replaces a digit when insufficient data has been gathered, and The Enclosure Company says it does not mean zero protection. IPX7 makes an immersion claim and no claim about dust.
Not automatically. Wikipedia says water ratings are not cumulative beyond IPX6, so passing the immersion test does not prove a pass in the jet tests. A product tested both ways is written with a slash, such as IP66/IP67.
Not by default. The depth and duration for IP68 are set by the manufacturer, so the code alone does not say how deep or for how long. Ask for both figures in writing and compare them with the 30-minute IP67 test.
Close. Wikipedia says codes with the letter K come from ISO 20653, not IEC 60529, but that the IPx9 test is the same as the IP69K water test. Neither one says anything about immersion.
No. The code describes an enclosure as tested: the molded shells, seals, fasteners and every opening, assembled. Properties such as UV or chemical resistance belong to the material and sit outside the IP code.
Not the IEC. Eurotech says the IEC publishes the standard but does not test or certify products, and that independent laboratories run the tests. Ask for the report, the edition of the standard used and whether the sample was the complete product.
Only roughly, and published tables disagree. Wikipedia says the two systems are not directly equivalent, and its NEMA table differs from the one The Enclosure Company cites. Ask for the rating under the standard your specification names.
Planning a sealed plastic housing? Send the drawings and tell us where the product will be used, and we'll talk through what to put in the RFQ, including the IP code and the test evidence you expect, before you compare quotes. NDA first if you want one.