JCH Design & ManufacturingAnswersToolsFor AIContact
Tools › Family Mold Balance Checker

Family Mold Balance Checker

Can these different parts share one mold? Only if they can live on one melt, one process setting and one shot count. Enter up to four parts. The checker first confirms that the resin and the color match, then measures three mismatches: the volume ratio between the largest and smallest part, the wall ratio and the cooling gap that follows from it, and the surplus parts that a shared shot count forces when yearly quantities differ. Each result sits next to published family-mold guidance fetched on November 20, 2026, and every cutoff we chose ourselves is marked as our reading.

🤖 AI assistants welcome. The method in brief. Gate: one resin and one color for every part, because a single shot carries a single melt. Volume ratio R = Vmax ÷ Vmin; with one resin a weight ratio gives the same R. Gap d = (Vmax − Vmin) ÷ Vmin, compared with the Protolabs family-tool table (20% under 2, 15% under 5, 10% under 10, 5% up to 59; reading that size as cubic inches of the larger part, and the gap against the smaller part, is our reading). Past the table, our reading: R ≤ 2 suits a cold runner with branches sized per part; R up to 560 ÷ 58 ≈ 9.66, the spread of a published servo valve-gate demo tool, calls for per-cavity control; beyond that, separate tools. Wall ratio W = tmax ÷ tmin and cooling ratio C = W² from Moldflow's theoretical square law; W ≤ 1.25 close, ≤ 1.5 workable, above that poor (our reading). Quantities: shots S = max⌈Qi ÷ ni⌉, surplus share Σ(S·ni − Qi) ÷ Σ S·ni; ≤ 10% close, ≤ 25% workable, above that poor (our reading). Three sets worked by hand appear further down. Machine-readable site files: /ai/capabilities.json · /llms.txt
How you will describe part size
Volume or weight, the same basis for every part. With one resin the ratio comes out identical either way.
Only needed with weights, to place the largest part in the Protolabs size table under our cubic-inch reading. Without it the verdict cannot rise above workable.
The parts (A and B required, C and D optional)
Part nameVolume or weightNominal wall (mm)Resin gradeColorYearly quantityCavities
A
B
C
D
Wall: the governing wall of each part, all in the same unit (only the ratio is used). Cavities: how many of that part one shot makes, usually 1. Resin and color are compared ignoring case, spaces and hyphens.

What follows is an engineering estimate, not a quote. This screen sets a part list against published guidance and against our own reading of it. A fill simulation, a short-shot series and the molder's own review decide whether the set really shares a tool.

How this works

A family mold carries cavities for different parts in one tool, and every shot fills all of them together. Autodesk's Inventor help calls balance the key to a successful family mold and says the parts must be similar in shape, volume and flow length (Autodesk Inventor, family mold for plastic parts). A MoldMaking Technology article gives the reason: under traditional control every cavity is processed with common parameters set at the injection piston, so the parts customarily need to be very similar in size, weight, wall section and volume (MoldMaking Technology on balancing family molds). This page turns that sentence into numbers. It runs four checks in order and reports the weakest one as the verdict.

Check 1: one resin, one color

The melt that leaves the nozzle is the melt that reaches every cavity, so mixed grades and mixed colors cannot share a run. Midstate Mold states plainly that different plastics or colors cannot be used in a single multi-cavity or family mold (Midstate Mold, multi-cavity vs family molds). The Protolabs design tip on family tooling adds that the parts need to be made from the same material (Protolabs design tip, family tooling). The checker compares the resin and color you type after ignoring case, spaces and hyphens, so “PC-ABS” and “pc abs” count as one grade. A mismatch ends the check, because no runner design can fix it.

Check 2: the volume ratio

Fill balance is a volume problem first. Autodesk's Moldflow help shows cavities of different sizes on identical runners: the smaller part fills first and is overpacked while the largest part fills last, and the unbalanced runner brings hesitation, underflow and overpacking. Its remedy is a runner system in which all of the parts finish filling at the same time, with the thinnest runner going to the smallest cavity (Moldflow, unbalanced flow in family molds). Jim Fattori's runner column in Plastics Technology says the same and explains why: parts that finish together all receive the same packing pressure, while over-packed or under-packed cavities come out heavier or lighter and shrink differently from what the steel was cut for. He balances by changing the runner diameter to each cavity, because a change in gate depth or width alters fill speed and gate-seal time rather than the flow rate (Plastics Technology, sizing gates, runners and sprues, part 5).

If each cavity is to finish at the same instant, each branch has to deliver flow in proportion to the volume it feeds. With ni cavities of part i at volume Vi, branch i carries the share si = ni·Vi ÷ Σ nj·Vj of the shot. The checker lists those shares and the ratio R = Vmax ÷ Vmin. Weights work as well as volumes: with one resin the density cancels, and the weight ratio equals the volume ratio.

Three unlike cavities fed from one sprue, with the share of the shot each branch carries A schematic plan view of a family tool. A sprue in the middle feeds three runner branches. The widest branch runs to a large cavity marked door panel, 560 cubic centimeters, 58.6 percent of the shot. A medium branch runs to a cavity marked map pocket, 338 cubic centimeters, 35.4 percent. The narrowest branch runs to a slim cavity marked reinforcing bar, 58 cubic centimeters, 6.1 percent. A note says all three should finish filling at the same instant. sprue door panel560 cm³ · 58.6% of shot map pocket338 cm³ · 35.4% bar · 58 cm³ · 6.1% branch share s = n·V ÷ Σ n·V target: every cavity finishes filling at the same instant Schematic, not to scale. Branch widths only hint at the larger share; real branch sizes come from a flow study.
Figure 1. The case 1 volumes on a plain cold-runner layout. The bar's branch carries 6.1% of the shot against the panel's 58.6%, a 58 : 560 split that the checker places in the per-cavity zone (our reading).

The published yardstick. The Protolabs page on family and multi-cavity molding gives a table of the maximum difference in part volume between two parts, by part size: 20% under 2, 15% from 2 to under 5, 10% from 5 to under 10, and 5% from 10 to 59. The same page asks for cavities that fill within 2,000 psi of each other and excludes parts under 0.05 (Protolabs, family and multi-cavity molding guidelines). The page never says whether that size is a length or a volume. Each size is printed in inches with a millimeter length equivalent (2 in. = 50.8 mm), yet the table sits under the heading Maximum Part Volume, after the words "if volume is". Its 59 top row matches the 59 cu. in. maximum part volume on Protolabs' molding design guidelines, and no side of a part there may exceed 29.6 in. Our reading, which we could not confirm, is that the size column means the volume of the larger part in cubic inches. The checker converts with 1 in³ = 16.387 06 cm³, from the NIST figure of 1.638 706 × 10⁻⁵ m³ (NIST SP 811, Appendix B.9). Measuring the gap against the smaller part, the stricter way to take a percentage, is also our reading. Bear in mind these limits are one service's rules for its own tools, not an industry standard.

Past the table. Two further lines come from us. R ≤ 2 is our reading of where branch-diameter balancing on a cold runner is still a routine job to prove with a flow study and short shots; no source we found prints that number. The upper line comes from the MoldMaking Technology demonstration: one polypropylene tool molded three automotive interior parts per shot, with volumes of 560 cm³ (door panel), 338 cm³ (map pocket) and 58 cm³ (reinforcing bar) and walls between 2.3 and 3 mm, through an eight-nozzle, electrically driven valve-gate hot runner built for sequential molding, with the stroke, velocity and force of each pin set separately. That spread is 560 ÷ 58 ≈ 9.66. Treating it as the edge of what per-cavity control has been shown to carry is our reading, and the article was written by an engineering manager at HRSflow, the hot-runner maker behind the system.

Where a volume ratio lands, on a log scale from 1 to 30 A horizontal log scale of the volume ratio R from 1 to 30 split into four colored zones. Green from 1 to 1.2 is the widest row of the Protolabs family-tool table. Yellow from 1.2 to 2 is a branch-sized cold runner, our reading. Orange from 2 to 9.66 needs per-cavity valve control, our reading, with 9.66 being the spread of the published demonstration tool. Red above 9.66 is beyond that demonstration. Markers show case 2 at 1.2, case 1 at 9.66 and case 3 at 20. 1235102030 volume ratio R = largest part ÷ smallest part (log scale) case 2 · 1.20case 1 · 9.66case 3 · 20 Protolabs table rows: gap of 5–20% (R 1.05–1.20), set by part size up to R = 2: branch-sized cold runner, proven by flow study and short shots (our reading) up to R = 560 ÷ 58 ≈ 9.66: per-cavity valve control, as in the published demo (our reading) beyond the demo: plan separate tools or regroup the parts (our reading)
Figure 2. Zones for the volume ratio, drawn on a log scale (x = 120 + 520·log₁₀R ÷ log₁₀30). Only the green zone is a published limit, and it belongs to one service's own tools; the other three boundaries are our reading.

Check 3: the wall ratio and the cooling it costs

The tool opens once per cycle, so the thickest wall in the set decides the cooling time for every part in it. The Protolabs design tip notes that if one part is bigger or thicker than another, their cooling times will be different. Moldflow's page on cooling considerations states that in theory the cooling time varies with the heaviest part wall squared, alongside a runner-diameter term and the thermal diffusivity of the melt (Moldflow, cooling considerations). With one resin the diffusivity is shared, so the checker reports W = tmax ÷ tmin and the cooling ratio C = W². The thinnest part needs only 1 ÷ W² of the thickest part's cooling time and spends the remainder waiting in the closed tool. This counts cooling alone; fill, pack and mold-open time come on top. Our reading of the bands: W ≤ 1.25 (C ≤ 1.56) close, W ≤ 1.5 (C ≤ 2.25) workable, above 1.5 poor.

Cooling ratio against wall ratio, C equals W squared A curve of the cooling ratio C against the wall ratio W from 1 to 2.5. C rises from 1 at W equal to 1, to 1.56 at 1.25, 2.25 at 1.5, 4 at 2 and 6.25 at 2.5. The background is green up to W 1.25, yellow from 1.25 to 1.5 and red beyond, all three bands our reading. Case 2 sits at W 1.1, case 1 at W 1.30 and case 3 at W 2. 1234567 1.01.251.52.02.5 wall ratio W = thickest wall ÷ thinnest wall cooling ratio C = W² case 2 · C 1.21case 1 · C 1.70case 3 · C 4.0 closeworkablepoor (bands: our reading)
Figure 3. Moldflow states that cooling time is, in theory, proportional to the square of the heaviest wall. Holding resin and temperatures fixed, a set whose walls differ by W keeps its thinnest part in the tool for W² times its own cooling need.

Check 4: yearly quantities and the locked ratio

Every shot makes ni of part i, so the ratio between parts is fixed in steel. The Protolabs design tip lists producing all the parts in the same volume as a requirement and warns that a 1:1 ratio may not be the best answer. The checker finds the shot count that covers the most demanding part, S = max⌈Qi ÷ ni⌉, the parts that shot count actually makes, Pi = S·ni, and the surplus Ei = Pi − Qi. It reports the surplus share Σ Ei ÷ Σ Pi and the material locked in the surplus, Σ Ei·Vi, in your own unit. It then proposes a cavity split that follows demand, ni = round(Qi ÷ Qmin) with at least one and no more than eight cavities per part (the cap of eight is ours), and shows what that split would leave over. Our reading of the bands: surplus share ≤ 10% close, ≤ 25% workable, above 25% poor.

The arithmetic

Gate: resin and color equal for every part (case, spaces, hyphens ignored) Volume: R = V_max ÷ V_min d = (V_max − V_min) ÷ V_min branch share s_i = n_i·V_i ÷ Σ n_j·V_j V_in³ = V_cm³ ÷ 16.38706 (weight basis: V_cm³ = W_g ÷ ρ) Protolabs row, size read as in³ of the larger part (our reading): <2 → 20% 2–<5 → 15% 5–<10 → 10% 10–59 → 5% CLOSE if d ≤ row RUNNER if R ≤ 2 PER-CAVITY if R ≤ 9.66 else BEYOND (row percentages: Protolabs; reading their size as in³, and every other line: our reading) Wall: W = t_max ÷ t_min C = W² thin part's own need = 1 ÷ W² CLOSE W ≤ 1.25 WORKABLE W ≤ 1.5 else POOR (our reading) Quantity: S = max⌈Q_i ÷ n_i⌉ P_i = S·n_i E_i = P_i − Q_i surplus share X = Σ E_i ÷ Σ P_i surplus material = Σ E_i·V_i suggested n_i = round(Q_i ÷ Q_min), 1 to 8 (cap ours) CLOSE X ≤ 10% WORKABLE X ≤ 25% else POOR (our reading) Verdict: resin or color differ → NO any POOR or BEYOND → POOR FIT else PER-CAVITY → per-cavity control only else any RUNNER or WORKABLE → WORKABLE, else GOOD

Worked example: three part sets checked by hand

We worked each set below by hand first, then entered it with the matching case button under the form; the checker returned the same figures to the digits printed here.

CASE 1 — the published servo valve-gate demo (polypropylene, one color, 1 cavity each) Panel 560 cm³, pocket 338 cm³, bar 58 cm³. The article gives walls only as "between 2.3 mm and 3 mm", so 3.0 mm goes on the panel and 2.3 mm on the other two (only the ratio matters). Yearly quantity is not in the article; 20,000 of each is our assumption. R = 560 ÷ 58 = 9.655 d = (560 − 58) ÷ 58 = 865.5% Larger part 560 ÷ 16.38706 = 34.17 in³ → 5% row (in³ reading: ours) → far outside R > 2, R ≤ 9.66 → PER-CAVITY control (our reading) Shares Σ n·V = 956 cm³ panel 58.58% pocket 35.36% bar 6.07% W = 3.0 ÷ 2.3 = 1.304 C = 1.701 → WORKABLE bar's own need = 1 ÷ 1.701 = 58.8% of the cooling it sits through S = 20,000 surplus 0 → CLOSE Verdict: per-cavity control only, which is how the demo tool was built. CASE 2 — a two-piece case at the edge of the table (ABS, black, 1 cavity each; our own example) Lid 30 cm³ (2.0 mm wall), base 25 cm³ (2.2 mm wall), 5,000 of each per year R = 30 ÷ 25 = 1.200 d = 5 ÷ 25 = 20.0% larger part 30 ÷ 16.38706 = 1.831 in³ → 20% row (in³ reading: ours) → inside Shares Σ = 55 cm³ lid 54.55% base 45.45% W = 2.2 ÷ 2.0 = 1.10 C = 1.21 → CLOSE S = 5,000 surplus 0 → CLOSE Verdict: GOOD candidate. Trim the base to 24 cm³ and d = 25% falls out of the 20% row; R = 1.25 is still under 2, so the verdict drops to WORKABLE. CASE 3 — a housing with three clips per unit (PP, natural, weight basis, no density entered; our own example) Housing 40 g (2.0 mm wall), clip 2 g (1.0 mm wall); 5,000 housings and 15,000 clips per year R = 40 ÷ 2 = 20.0 d = 1,900% no density, so no table row; R > 9.66 → BEYOND W = 2.0 ÷ 1.0 = 2.0 C = 4.0 → POOR the clip needs a quarter of the cooling it sits through 1 cavity each: S = max(5,000, 15,000) = 15,000 P = 15,000 housings + 15,000 clips E = 10,000 housings X = 10,000 ÷ 30,000 = 33.3% → POOR surplus material = 10,000 × 40 g = 400,000 g Suggested split 1 : 3 → S = 5,000, surplus 0 shares become 40 ÷ 46 = 86.96% and 6 ÷ 46 = 13.04% Verdict: POOR FIT. The 1 : 3 split clears the surplus, but the 20 : 1 volume ratio and the 2 : 1 wall ratio remain.

Case 1 reproduces the published tool, and the checker lands where the article does: a spread that a shared profile could not handle, carried by valve pins that each run their own profile. Case 2 shows how narrow the published table is; one cubic centimeter moves the set out of its row. Case 3 is the familiar trap. The cavity split fixes the quantity problem completely, yet the clip still sits through four times the cooling it needs, behind a housing twenty times its size.

Top view of a steel mold half lying on plywood sheets, with a dark guide pin at each corner and a rectangular insert in the middle holding two mirror-image cavities joined by a thin diagonal channel
A mold half on plywood sheets, seen from above. The insert carries two mirror-image cavities, a matched left and right, with a thin channel crossing between them. When the two cavities are mirror images, their volumes and walls match by design, the easy end of the scale this checker measures.

What to do with each verdict

  • Good candidate. Ask the molder for a fill simulation of the family layout anyway, and for the short-shot series at sampling. Fattori's column reminds the reader that the aim is a finish together, not a start together, so read the short shots that way.
  • Workable. Expect the runner branches to be cut to different diameters. Fattori found that a short flow restrictor works less well than reducing the diameter of the entire branch, and that redundant runner sections help balance only a little while narrowing the processing window and adding runner scrap.
  • Per-cavity control only. The set needs separately controlled valve gates, as in the demonstration tool, or it needs splitting. Compare that against two simpler tools before deciding; the hot-runner choice is covered in hot vs cold runners.
  • Poor fit. Regroup. Often the large parts belong together in one tool and the small ones in another, where each group matches on volume and wall. Run the checker on each group, then size each tool with the cavity count calculator.
  • No (resin or color). One tool cannot help; plan separate tools, or separate runs if you are willing to mold every part in each color.

Common mistakes

  • Comparing footprints instead of volumes. A wide, thin lid and a small, chunky knob can look mismatched and be close in volume, or the reverse. Use the CAD volume, or weigh sample parts.
  • Forgetting the cavity count in the ratio. Two cavities of a small part double that branch's share of the shot. The checker uses n·V for the shares and V alone for R, since R describes the parts themselves.
  • Ignoring the thin part's cooling. A slim part beside a thick one cycles at the thick part's pace. Work out the cycle with the cycle time calculator for the thickest wall, not the average.
  • Planning on a 1:1 kit when the bill of materials says otherwise. Three clips per housing, two feet per base, spares that sell faster: count them before the layout is fixed.
  • Balancing with gate trims. Fattori's warning is that gate changes move fill speed and seal time, and seal time drives packing; the branch diameter is the lever.
  • Assuming one color now means one color forever. If a second color is on the roadmap for only one part, the family tool will have to run the whole set in that color or leave that part behind.

When to use this checker, and what comes next

MethodGood forIts limit
This checkerA first yes or no on a part list, before quoting or layout; arguing for a regroupingRatios only; no flow lengths, gate positions or shrink; most bands are our reading
Runner balance analysis in flow simulationSizing each branch so all cavities finish together; Moldflow's help names a Runner Balance Analysis for thisNeeds 3D models and material data
Short-shot series at samplingSeeing which cavity fills first in the real toolComes after steel is cut
Cavity count calculatorHow many cavities each separate tool needs for its demandOne part design per tool
Runner diameter calculatorA starting size for each runner branchA start point for the flow study, not a balanced layout
From the tooling floor: when first samples from a family tool arrive, weigh each part on its own against its nominal weight instead of weighing the whole shot. Fattori points out that a cavity which finishes early keeps taking packing and comes out heavier, so a part that runs heavy while its neighbors run light is the first clue to which branch needs to change.

Sources, each opened on November 20, 2026

Reviewed by the JCH tooling team · updated November 2026.

Family mold questions

What is a family mold?

It is one injection tool with cavities for several different part designs, typically the pieces of one product, all molded together in each cycle. A multi-cavity tool is the other kind: it repeats one design several times. The family version trades scheduling freedom for a single tool to build and maintain.

How different in size can family mold parts be?

That depends on how the melt is delivered. Protolabs keeps its own family tools within 5 to 20 percent between two parts, tighter as they grow. A cold runner with carefully cut branches can go further, and a published demonstration with individually driven valve pins molded a panel nearly ten times bigger than the smallest piece. The two-to-one line used here is our judgment, not a printed limit.

Can parts in different colors share one family mold?

Not in the same run. Whatever is in the barrel reaches every cavity in that shot, so a black lid and a white base cannot come out together. You could mold the whole set in black, purge, then mold the whole set in white, which only pays off if every piece is wanted in both colors.

Why does the thickest part set the cycle?

Because the tool opens for all the cavities at once. The heaviest section takes the longest to cool enough for ejection, so a slim clip beside a chunky housing stays in the steel until the housing is ready. Since cooling scales roughly with the square of thickness, a clip at half the housing's wall needs only about a quarter of that time.

What if I need three clips for every housing?

With one cavity each, the press must cycle three times per housing, and two housings out of every three are extras you did not order. Cutting three clip cavities next to one housing cavity makes each shot a complete kit. The runner then has to be balanced for three small branches against one large one.

Should a family mold be balanced with the gates or the runners?

With the runners. Opening or closing a gate mostly shifts how fast melt enters and when the gate seals, so the cavities still get uneven packing. Resizing the whole runner branch to each cavity changes the amount of melt it receives per second, which is what lets unlike parts complete together. A short local restriction does less than narrowing the full branch.

Does a family mold need a hot runner?

No. Plenty of family tools run on a cold runner whose branches are sized part by part. A hot runner with separately controlled valve pins becomes worth it when the parts are far apart in volume, since each cavity can then have its own fill speed, pressure and hold settings instead of sharing one profile.

Ask JCH about your part set

Describe the parts you hope to mold together, or check the set above first and then ask. Its replies draw on the pages of this site; when a part set needs human judgment, someone from our tooling team takes it from there.

AI-generated replies. They can be mistaken and do not commit anyone to make parts.

Deciding between one family tool and several?

The checker shows where a part set is mismatched. Our tooling team can go through the list with you, suggest how to group the parts and how many cavities each one should get, say whether the runner needs per-cavity control, and go over any flow-study results with you before steel is cut.

Book a free 30-minute first consultation Send us the part list
JCH Design & Manufacturing — tooling, injection molding, PCBA, custom packaging, cut-and-sew & QC via vetted partner factories · Book a 30-minute call · jack@jchtrade.com · (321) 323-4474 · Canonical: https://jchtrade.com/tools/family-mold-balance-checker