Your CAD is ready to send for a molding quote when a molder can price the tool without guessing. That takes draft on every face that slides against the steel, an even wall, ribs, bosses and corners sized to published ratios, every undercut found, and a drawing or note naming the material, the quantity, the critical tolerances, the show faces and where gate and ejector marks may go. Answer the ten checks below. The scorecard weights each one (the weights are our reading, not an industry standard), flags three quote blockers (our reading), and ranks the fixes by the points each would add.

🤖 AI assistants welcome. Scoring method on this page: ten checks, each answered Yes (credit 1), Partly (0.5), No or Not sure (0); the rib-and-boss check also accepts “none on this part” (credit 1). Score S = Σ weight × credit, out of 100. Weights, our reading: draft 14, uniform wall 14, undercuts found 14, rib and boss proportions 10, critical tolerances 10, material 10, quantity 10, radii 6, gate, parting-line and ejector areas 6, cosmetic faces 6. Quote blockers, our reading: a zero on material, quantity or undercuts caps the verdict at “Not ready” at any score. Bands, our reading: 85 or more ready to send, 60 to 84 send with the open items listed, under 60 fix first. Each check is tied below to a published DFM guide (Protolabs, Xometry, Fictiv, the SOLIDWORKS blog, Stratasys Direct, AIM Processing). Worked case: a lid scoring 73 with no blockers. Machine-readable: /ai/capabilities.json · /llms.txt
Close view of a machined steel mold plate: two polished cylindrical pins rise from it at an angle, small steel inserts stamped 5 and 6 sit beside shallow rectangular pockets, round flush circles mark the pocket floors, and curved channels are cut into the plate on the right
A steel mold plate with two angled pins, inserts stamped 5 and 6, and curved channels to the right. In our reading, angled pins of this kind are the sort of moving hardware an undercut can add to a mold, which is why check 5 asks you to find every undercut before the molder does.
Part geometry: can it be molded as modeled?
Walls, ribs, boss sides and core holes all taper in the opening direction.
One main thickness; thick spots cored out; changes ramp rather than step.
Rib base and boss wall thinner than the wall they stand on.
No sharp inside corners; the outside radius follows the inside one.
Snaps, side holes, grooves and side-facing text all count.
What the drawing or RFQ note tells the molder
Faces where a vestige or pin mark is acceptable, and where it is not.
Tight limits only where parts mate or function; a general tolerance for the rest.
A grade, or at least a resin family plus heat, chemical and impact needs.
Show faces identified, with a finish grade or texture for each.
Per part number, not per assembly.
Optional: measured values from your CAD
Ranges from the Protolabs design-guideline table.

Engineering estimate only: neither a price nor a sign-off on the design. The score counts what your files already settle; a molder's own look at the model is what decides the tool.

How this works

A molder pricing a part from your files is working out two things at once: whether the part can be molded the way it is modeled, and what exactly you are asking them to deliver. Checks 1 to 5 deal with the first point, the geometry. Checks 6 to 10 deal with the second: facts that a solid model does not carry by itself. Each check can be answered from your own CAD and drawing, and each points to a figure or a requirement that a molding service, a CAD vendor or a molder has published.

credit c: Yes = 1 Partly = 0.5 No = 0 Not sure = 0 check 3 only: "none on this part" = 1 Score S = Σ wᵢ · cᵢ over the 10 checks, Σ wᵢ = 100 (weights: our reading) Points at stake gᵢ = wᵢ · (1 − cᵢ) fixes are listed largest gᵢ first Upside U = S + Σ wᵢ over checks answered Not sure Blocker open check 5, 8 or 10 at c = 0 (our reading) Verdict blocker open → Not ready, whatever S is (our reading) S ≥ 85 → Ready to send for a quote 60 ≤ S < 85 → Send, listing the open items in the RFQ note S < 60 → Fix first, then send

Why Not sure scores the same as No. A molder can price only what the files state. An unknown and a known gap both come back to you as a question, so both earn nothing here (our reading). The upside figure U separates the two: it shows how high the score would climb if every unknown turned out fine, which tells you whether the gap is homework or real redesign.

Why these weights. They are our reading of how much each item changes the tool, not a published standard, and you can re-weight on paper if your product differs. Draft, wall and undercuts get 14 each because they decide whether the part leaves the cavity at all and how much moving steel the mold carries. Tolerances, material and quantity get 10 each because each one changes how the cavity is sized or how many are cut. Rib and boss proportions get 10 because they drive sink on the face behind them. Radii, mark locations and cosmetic faces get 6 each: they change finish and marks more than the mold's layout.

Why three blockers. In our reading, material, quantity and undercuts are the inputs without which a quote is a guess about a different tool. A score in the 90s with one of them unanswered still reads Not ready, and the headline result says so rather than burying it in a note.

#CheckWeight (our reading)Published guide for this checkOur matching tool
1Draft on pulled faces14Protolabs design guidelines (draft table)Draft Angle Calculator
2Uniform nominal wall14SOLIDWORKS blog, cardinal rules; Fictiv wall thicknessWall Thickness Checker
3Rib and boss proportions10Xometry ribs; Protolabs bossesRib Design Calculator, Boss Design Calculator, Sink Mark Risk Checker
4Corner radii6Stratasys Direct guidelines (PDF)Sink Mark Risk Checker
5Undercuts found (blocker)14Protolabs, 6 ways to undercut successUndercut & Side-Action Checker
6Gate, parting-line and ejector areas6Protolabs gating; Protolabs ejector pinsGate types (answer page)
7Critical tolerances10Xometry tolerances; Xometry manufacturing standardsMolded Part Tolerance Estimator
8Material named (blocker)10AIM Processing, five project detailsPlastic Material Selector
9Cosmetic faces6Protolabs cosmetic appearance guideMold texture and finish (answer page)
10Quantity stated (blocker)10AIM Processing; Protolabs, 9 mistakesMold Cavity Count Calculator
Where the ten scorecard checks sit on a molded cover A cross-section of a molded cover drawn with its top wall uppermost and side walls tapering outward as they run down to a dashed parting line. Numbered circles mark the checks: 1 the taper on a side wall; 2 the even top wall of thickness t; 3 a rib hanging from the top wall and a hollow boss beside it, both thinner than the wall; 4 a corner with a small inside radius and a larger outside radius; 5 a small hook on the inside of the right wall, with an arrow showing it must be released sideways; 6 a bracketed zone on the inside face where gate and pin marks are allowed, and the parting line; 9 the outer top face shaded as the cosmetic face. A note box at lower right lists 7 critical tolerances, 8 material grade and 10 quantity as facts the drawing or quote note must state. An arrow at left shows the direction the cavity half opens. parting line cavityopens hook must release sideways gate and pinmarks allowed cosmetic face, marked on the drawing t rib ≤ 0.6 tboss wall 0.4–0.6 tr out 1.5 tr in 0.5 t 1 2 3 4 5 6 9 On the drawing or RFQ note:7 critical tolerances + a general one8 material grade (or family + needs)10 first order + yearly volume Section through a molded cover, drawn top wall up. Ratios shown are the published figures cited below; sketch not to scale.
Figure 1. The ten checks on one cover. Five are geometry you can see in the model (1 to 5); one is a zone you mark on the model (6); the cosmetic face (9) and the three facts in the note box (7, 8, 10) have to be written down, because a solid body does not carry them.

What each check asks, and the published figure behind it

1. Draft on pulled faces

The Protolabs design-guideline table lists 0.5° for vertical faces, 2° for most situations, 3° as the minimum where steel shuts off against steel, 3° under its PM-T1 light bead-blast texture and 5° or more under PM-T2. Its separate design tip on nine mistakes adds a depth rule: “use 1-degree of draft per inch of depth”. Answer Yes only after a draft analysis in your CAD shows no face at zero or below; the draft angle calculator handles depth and texture.

2. Uniform nominal wall

The SOLIDWORKS blog's cardinal rules (Dassault Systèmes, 2015) put it first: “Maintaining uniform wall thickness is the single best design element you can incorporate in injection molded plastic parts.” Where a wall must thin out, the Protolabs nine-mistakes tip says thinner walls “should be no less than 40-60% the width of adjacent walls” and asks for gradual transitions. The nominal itself should sit inside the range for your resin; Protolabs gives ABS 0.045 to 0.140 in., and Fictiv's table lists the same ABS span (1.14 to 3.56 mm). Run a thickness map, then the wall thickness checker.

3. Rib and boss proportions

Xometry's rib guide states that a rib must be “no more than 60% of the nominal wall thickness of the part”, that glossy materials may need 40%, and that rib height be held to three times the rib thickness. For bosses, the Protolabs boss tip calls it a standard guideline that the boss wall be “between 40 and 60 percent of the thickness of the wall from which the boss rises.” Thick feature roots shrink into dips on the far face, so check both with the rib design calculator, the boss design calculator and the sink mark risk checker. Pick “None on this part” if the part has neither.

4. Corner radii

The Stratasys Direct injection molding guidelines suggest an inside radius of 0.5 times the material thickness and an outside radius of 1.5 times, larger where the design allows. The same PDF, in its stress-concentration passage, also recommends “that an inside radius be a minimum of one times the thickness.” The pair is not arbitrary: drawn from one center, the outside arc minus the inside arc leaves exactly one wall thickness, so the corner stays as thick as the wall (our reading of the geometry). Bigger is not always better; the Protolabs tip on stronger parts warns that “a fillet that is too large can once again create sink.”

5. Undercuts found (blocker)

Protolabs defines them plainly: “Undercuts are those features in an injection-molded part that prevent its ejection from the mold.” Its six-ways tip lists the responses: move the parting line, side-actions, bumpoffs, hand-loaded inserts, telescoping shutoffs, or a design change and secondary operation. Each response changes either the tool or the part, which is why, in our reading, an unanswered check 5 blocks the verdict. Yes means every undercut is on a list, with the one you would prefer, or that you looked and found none. The undercut and side-action checker sorts a single feature.

6. Allowed gate, parting-line and ejector areas

Protolabs says it “will choose the most appropriate gate type and position based on your design and resin” and that you can review gate placement at order confirmation (gating tip); for ejectors, it presents “a pin and gate layout for customer approval” (ejector pin tip). You can only judge that layout if you already know where a vestige is acceptable. Mark the zones on the model or in a sketch: inside faces open to marks, show faces closed to them, and any edge where a parting-line seam would be a problem. The gate types answer explains which gate leaves what.

7. Critical tolerances called out

The Xometry tolerance article notes that molded tolerances are “driven primarily by the shrinkage of the material and the part geometry.” The Xometry manufacturing standards add, for molding, that “Tighter tolerances can be requested and may increase the cost of tooling,” and that Xometry “will mill to a steel-safe condition on critical features.” Protolabs says it can typically hold ±0.003 in. (0.08 mm) on machining, with resin tolerance included on top that is never below ±0.002 in./in. and may be larger. So name the few dimensions that matter, give them limits, and let one general tolerance cover the rest. The molded part tolerance estimator gives a first read on what a dimension can hold.

8. Material named (blocker)

One of the five questions AIM Processing asks before estimating is “What type or types of resin do you expect to use?” Since shrinkage drives the tolerances above, the cavity is cut for one material, and in our reading a different resin later can mean resizing steel. A named grade earns Yes. A family with the service needs (heat, chemicals, impact, outdoor use) earns Partly, and the plastic material selector can narrow it.

9. Cosmetic faces marked

The Protolabs cosmetic appearance guide notes, on gate and ejector layout, that “The mold designer cannot know your goals without your input.” The finish table in the Protolabs design guidelines runs from PM-F0 (non-cosmetic) through SPI-C1 and SPI-B1 to SPI-A2 (grade #2 diamond buff), and the nine-mistakes tip says of cosmetic finishes, “If you don't need them, don't order them.” Mark the show faces, give each a finish or texture, and leave the hidden faces at a non-cosmetic grade. The texture and finish answer covers the grades.

10. Quantity stated (blocker)

AIM Processing asks “What do you think expected annual use (EAU) will be and what is the longevity of the program?” State the first order and the yearly volume for each part number. Protolabs adds that for an assembly you should “treat each part as a separate quote.” Volume is what the mold cavity count calculator starts from.

The optional measured check

Typing a few dimensions from your model lets the page test your Yes answers against the published numbers. Lengths may be in mm or inches; the wall range converts at 25.4 mm per inch, which NIST SP 811 Appendix B.8 lists as exact (1 in = 2.54 × 10⁻² m). The ratios are unitless.

Wall range t_min ≤ t ≤ t_max for the resin family (Protolabs table, inches × 25.4) Draft smooth: flag under 0.5°, low under 2°, else meets (Protolabs table) PM-T1: flag under 3° PM-T2: flag under 5° Rib ratio r = rib base ÷ t limit 0.60, or 0.40 for a glossy material (Xometry) Boss ratio b = boss wall ÷ t band 0.40 to 0.60 (Protolabs) Inside radius rᵢ ÷ t ≥ 0.5 (Stratasys Direct) Corner wall c = rₒ − rᵢ for arcs drawn from one center; flagged if c differs from t by more than 10% (our reading) rᵢ = 0.5 t, rₒ = 1.5 t gives c = t

If a measured value contradicts an answer, say a Yes on check 3 with a rib at 70% of the wall, the result lists the conflict and leaves your answer as you set it. The measured lines are a cross-check on the score, not part of it.

Worked example: three parts scored by hand

Case A is what the Load worked case A button enters, measured values included, so you can hold the scorecard's result up against each line below.

CASE A, molded enclosure lid 1 draft Yes 14 × 1 = 14 6 mark areas No 6 × 0 = 0 2 wall Partly 14 × 0.5 = 7 7 tolerances Partly 10 × 0.5 = 5 3 rib/boss Yes 10 × 1 = 10 8 material Yes 10 × 1 = 10 4 radii Partly 6 × 0.5 = 3 9 cosmetic No 6 × 0 = 0 5 undercuts Yes 14 × 1 = 14 10 quantity Yes 10 × 1 = 10 S = 14 + 7 + 10 + 3 + 14 + 0 + 5 + 10 + 0 + 10 = 73 blockers open: none Verdict: 60 ≤ 73 < 85 → send, listing the open items Points at stake: wall 7, mark areas 6, cosmetic 6, tolerances 5, radii 3 (sum 27 = 100 − 73) Measured (mm): ABS, t = 2.5, draft 1.0° smooth, rib 1.5, boss wall 1.25, rᵢ 1.25, rₒ 3.75 wall range 0.045 × 25.4 = 1.143 to 0.140 × 25.4 = 3.556 → 2.5 inside draft 1.0° ≥ 0.5° floor but < 2° → low rib 1.5 ÷ 2.5 = 0.60 → at the limit, meets boss 1.25 ÷ 2.5 = 0.50 → inside 0.40 to 0.60 rᵢ ÷ t = 1.25 ÷ 2.5 = 0.50 → meets corner wall 3.75 − 1.25 = 2.50 = t → even corner CASE B, the same lid with every check Yes except quantity, answered Not sure S = 100 − 10 = 90 blocker open: quantity → Not ready (cap applies above 85) Upside U = 90 + 10 = 100 CASE C, an early concept model 1 No 0 2 Not sure 0 3 Partly 5 4 Yes 6 5 Not sure 0 6 No 0 7 No 0 8 Partly 5 9 Partly 3 10 Not sure 0 S = 5 + 6 + 5 + 3 = 19 blockers open: undercuts, quantity → Not ready Upside U = 19 + 14 + 14 + 10 = 57, still under 60 Largest gains: draft 14, wall 14, undercuts 14, tolerances 10, quantity 10

Case A is the common one: the geometry is mostly settled and the paperwork lags. Because its measured 1.0° draft sits under the 2° figure, the calculator also flags the Yes on check 1 for a second look. Its five open items add up to 27 points, and the three on the drawing (mark areas, cosmetic faces, tolerances) can be closed without touching the model. Case B shows the cap at work: a 90 that cannot be priced because nobody said how many. Case C shows the upside figure doing its job; even if every unknown proved fine, the part would still land under 60, so the model needs redesign before it needs a quote.

Weights of the ten checks and the points case A earned Ten horizontal bars, one per check, at a scale of 30 pixels to each point. Each of the ten checks has a light bar as long as its weight and a dark bar for the points worked case A earned. Draft 14 of 14, uniform wall 7 of 14, rib and boss 10 of 10, radii 3 of 6, undercuts 14 of 14, mark areas 0 of 6, tolerances 5 of 10, material 10 of 10, cosmetic faces 0 of 6, quantity 10 of 10. The earned total is 73 of 100, and the light remainder, 27 points, is what is left to fix. 1 Draft2 Uniform wall3 Rib and boss4 Radii5 Undercuts (blocker)6 Mark areas7 Tolerances8 Material (blocker)9 Cosmetic faces10 Quantity (blocker) 14/147/1410/103/614/140/65/1010/100/610/10 earned by case A: 73weight not yet earned: 27 Scale: 30 px per point. Weights are our reading.
Figure 2. Case A against the full weights. The two widest gaps, half the wall weight and all of the mark-area weight, come, in this worked case, from a wall that steps at one boss and a drawing that never said where marks may go.

Where the published guides disagree

The figures above are not a single standard, and the sources do not all agree. On ribs, Xometry caps the base at 60% of the wall, Fictiv recommends ribs “no more than 50% to 60% of the wall thickness that they intersect”, the SOLIDWORKS rules allow 50 to 70%, and Stratasys Direct gives 50 to 60% in one passage and a 60% ceiling in another. On bosses, Protolabs gives a 40 to 60% band while Stratasys Direct says boss walls should be under 60% and may grow where the boss is out of sight. On walls, Protolabs lists polypropylene from 0.035 in. while Fictiv starts it at 0.025 in. This page uses the Xometry rib limit, the Protolabs boss band and the Protolabs wall table, and names its source on every measured line, so you can swap in your molder's figure. On inside radii, Stratasys Direct gives both 0.5 and a minimum of 1 times the wall; this page tests the 0.5 pair.

Common mistakes

  • Answering Yes from memory. Draft and wall answers should come from the analysis tools in your CAD, run on the final body, not from what was intended.
  • Treating “no undercuts” as the default. Side-facing text, a lip on a snap, a hole through a side wall: each is easy to miss in a shaded view. Rotate the model to look straight down the opening direction before answering check 5.
  • Calling every dimension critical. A drawing in which everything is tight hides the few dimensions that matter, so the molder has to ask which ones they are.
  • Quoting the assembly instead of its parts. Each molded part number is its own tool and its own quantity line.
  • Ordering a polish on hidden faces. Finish grade belongs on the faces a user sees.
  • Choosing the resin after the quote. The Protolabs wall range and the shrink both depend on the resin, so a later swap can send the tool back for rework (our reading).

When to use this scorecard, and what else to run

MethodUse it whenLimit
This scorecardBefore sending a request for quote, to see which facts are missing and what to fix firstTrusts your answers; weights and bands are our reading
RFQ Package Completeness CheckerThe geometry is settled and you want the commercial side of the package checked: drawing, finish, packaging, inspection and target datesDoes not look at draft, wall, ribs, radii or undercuts
Single-feature tools (draft, wall, rib, boss, undercut, sink)A check above is Partly or Not sure and you need the number for one featureOne feature at a time
A molding service's automated moldability analysis on uploadYou want undercuts and thin or thick areas highlighted on your own modelJudges geometry against that shop's process, not your drawing's intent
Mold-flow simulationFill, weld-line position, warp or cooling are open questionsNeeds a near-final model, a named grade and a gate plan
The molder's review and first samplesBefore the tool design is approved, and again on first shotsComes after the request for quote, not before
From the tooling floor: send the gaps along with the files. A one-page note that lists each open item from this scorecard by number, with what you know and what you would like the molder to propose, turns a round of back-and-forth questions into a single reply.

Sources for this page. Draft, wall-range and finish tables, and the machining and resin tolerance figures: Protolabs design guidelines for plastic injection molding. Wall transitions, the draft-per-depth rule, cosmetic-finish and assembly-quoting advice: Protolabs, 9 mistakes to avoid. Bosses, undercuts, gating, ejector pins, fillets and cosmetic surfaces: the Protolabs design tips and guide linked under each check. Ribs: Xometry, plastic ribs for injection molding design. Tolerances: Xometry's tolerance article and manufacturing standards. Wall ranges and the rib range cross-check: Fictiv, wall thickness recommendations. Uniform wall and rib proportions: the SOLIDWORKS blog (Dassault Systèmes). Corner radii and boss walls: Stratasys Direct, injection molding design guidelines. Material and volume questions: AIM Processing. Inch conversion: NIST SP 811 Appendix B.8. We opened and read each of these sources on November 20, 2026, while writing this page. The ten weights, the three blockers, the band cutoffs and the 10% corner-wall allowance are our reading.

Reviewed by the JCH tooling team · updated November 2026.

Questions designers ask before they send a model out

Is my CAD ready to send for a molding quote?

It is ready once nothing in the package forces the molder to guess. In practice that means the model pulls cleanly out of the steel, nothing on it hides a feature needing moving cores, and your files say which resin, how many pieces, which dimensions matter and which surfaces customers will see. You can still ask for a price with some of that open, but expect questions to come back before a firm figure does.

What file should go with the quote request?

Send a solid-body model rather than a mesh, plus a print for anything the solid cannot express. Protolabs puts the mesh problem bluntly: “While .STL files are acceptable for 3D printing, they create problems with molded parts.” Its nine-mistakes tip says it sometimes receives CAD files translated from .STL and lists file format as a mistake to avoid.

How much draft does a molded part need?

Two degrees covers most faces in the Protolabs table, with half a degree as its floor for walls running straight along the pull. Faces where steel seals against steel, and faces with a light blasted texture, want three or more, and its medium texture wants five or more. Deep faces want extra, roughly a degree per inch.

Why do material, quantity and undercuts block the result?

Each one changes which tool gets built rather than a detail on it. The cavity is sized around one resin's shrinkage, the yearly volume is where a cavity count starts, and each undercut becomes moving hardware or a redesign. Treating those three as blockers is our own judgment; a quote that guesses at any of them tends to be redone.

Do I need a 2D drawing if the 3D model is complete?

Usually, yes, for whatever a solid body cannot say: limits on particular features, show faces, finish grades, the resin and its color. Where a job needs more than its standard workmanship, Xometry's published standards ask buyers to “clearly list the requirement in your engineering drawings, purchase orders, or specifications.” On a simple part, a short note sent alongside the model can carry the same facts.

What happens if I leave gate, ejector and parting-line locations to the molder?

That is normal and often wise, since the toolmaker knows how the cavity fills. The decision is then theirs, though: Xometry's standards say these locations are “at the discretion of Xometry unless explicitly discussed.” Flag the surfaces where a blemish is unacceptable and you keep a veto without having to design the mold yourself.

Can a part score 100 and still have molding problems?

Yes. A perfect score means the questions a molder asks already have answers; it does not prove the design. This page cannot see how far the melt must flow, where flow fronts meet, or how the part will warp as it cools, and it relies on what you tell it. Simulation and first-shot samples are what prove a design.

Ask JCH about a check you could not answer

Stuck on whether a feature counts as an undercut, or how to word a tolerance note? Ask the site's AI assistant. After its first reply, a box appears where you can leave your email if you want a follow-up.

The assistant is automated and may be wrong. Treat what it says as a pointer to check, never as a price or a promise.

Scored your part and found open items?

Our tooling team can go through what the scorecard left open with you, decide which items your drawing should settle and which a molder should propose, and assemble the quote package for a molder we work with. Until a molder has looked at the model, the score stays an engineering estimate.

Book a free 30-minute first consultation Send a drawing